Application Range
Temperature sensors of the T.3 series are designed for use in the shipbuilding industry, machinery, and equipment. They measure temperatures of cooling water, lube oil, etc., in engines or gearboxes.
Measuring Principle
The TH3 series uses NTC measuring elements, while the TP3 series uses Pt100 (or Pt1000 on request). Platinum measuring elements offer accurate, reproducible characteristics, and are easy to replace without calibration. NTC elements are semiconductor resistors with a negative temperature coefficient, improving conductivity at higher temperatures.
Specific Features
  • Compact, robust design
  • Easy installation via protection tube
  • Pressure resistance up to 40 bar
  • Available in different immersion depths
  • Compatible with various measuring transducers and indicators
Technical Data
  • Temperature range: TH31 (40...120 °C), TH32 (0...70 °C), TP31 (0...120 °C)
  • Protection class: IP54, IP68 with protection tube
  • Material: Copper nickel-plated sensor tube, plastic adapter
  • Immersion depth: 56 mm, 100 mm (other lengths on request)
  • Pressure resistance: 40 bar
Dimensions and Connections
Dimensions are provided for the sensor and protection tubes, with specific measurements for length, diameter, and thread types. The protection tubes are available in brass or stainless steel, with various thread options.
Type Code
The type code structure includes measuring principle, construction type, measuring range, and insertion length. Preferred types are available quickly from stock, while special types can be developed upon request.
See more

Catalog excerpts

Datasheet TP31 TH31-1

Measuring principle Application range Temperature sensors of the T.3. series are especially designed for use in: Shipbuilding industry, machinery and equipment. They measure the temperatures of cooling water, lube oil, etc. e. g. of engines or gearboxes. Measuring principle Temperature sensors of the TH3. series operate with the measuring element: NTC . Temperature sensors of the TP3. series operate with the measuring element: Pt100 (or Pt1000 on request). Functioning of platinum measuring elements With this measuring principle the temperature-sensitive resistance value of the measuring element is acquired. For platinum measuring elements the electrical resistance increases with increasing temperature and decreases with decreasing temperature (temperature linear). Advantages of platinum measuring elements are: • accurate and reproducible thermoelectric characteristics • nearly linear temperature characteristic • easy to replace (no calibration necessary, corresponding to international standards, e. g. IEC 751 / DIN EN 60751) • easier handling towards thermocouples as cold junction is not necessary NTC is a temperature sensitive semiconductor resistor with a negative temperature coefficient. It is a volume resistance that consists of ceramic materials based on metal oxides, such as ferric oxide (Fe2O3), ZnTiO4, and magnesium dichromate (Mg-Cr2O4). With high temperatures the conducting capacity is better than with lower temperatures. Specific features • Compact, robust design • Easy installation via protection tube • Connection with flat connector, lateral cable outlet • Pressure resistance up to 40 bar • Available in different immersion depths • Suitable measuring transducers, limit value switches and analogue indicators available • Sensor with Pt100 or NTC measuring element available Datasheet DB-T.3.-EN | V01.03 | 14/12/2015 | Valid from product revision Rev.- | www.noris-group.com | [email protected]

 Open the catalog to page 1
Datasheet TP31 TH31-2

| Dimensions, connections and drawings NORIS Automation GmbH Explanation to the illustration The left illustration shows type T.3...(see type code): A: length 40 mm B: Insertion length + 2 mm (see type code) C: Length 18 mm D: Diameter 0 10 mm E: Diameter 0 12.5 mm F: Colour of the sensor head (see type code) G: Cable entry not included in scope of delivery, see table below H: Flat connector A6.3 x 0.8 DIN46244 Explanation to the illustration A: Diameter 0 39 mm B: Length 55 mm Explanation to the illustration The left illustration shows the protection tube MX2 (brass), MX5 (stainless steel) for...

 Open the catalog to page 2
Datasheet TP31 TH31-3

NORIS Automation GmbH Technical data | DB-T.3. NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | [email protected] | www.noris-group.com Errors and omissions excepted

 Open the catalog to page 3
Datasheet TP31 TH31-4

| Type code NORIS Automation GmbH DB-T.3. NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | [email protected] | www.noris-group.com Errors and omissions excepted

 Open the catalog to page 4
Datasheet TP31 TH31-5

NORIS Automation GmbH Type code | DB-T.3. NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | [email protected] | www.noris-group.com Errors and omissions excepted

 Open the catalog to page 5

All NORIS Group GmbH catalogs and brochures

  1. Datasheet RG5

    2  Pages

  2. Datasheet FA13

    14  Pages

  3. Datasheet NIQ31

    16  Pages

  4. Datasheet FA54

    11  Pages

  5. NORIS Brochure

    15  Pages

  6. Datasheet EOT

    6  Pages

  7. Datasheet DWA

    4  Pages

  8. Datasheet VF5

    2  Pages

  9. Datasheet RF5

    2  Pages

  10. Datasheet RI5

    2  Pages

  11. Datasheet RH5

    2  Pages

  12. Datasheet RW5

    2  Pages

  13. Datasheet VP5

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.