Overview: The document provides technical specifications and operational details for the RH5 series limit-value switches, designed for monitoring and processing electrical measured variables, particularly temperature using NTC thermistors.
Specifications:
  • Supply Voltage: 18-32 V/DC, with reverse voltage protection and overvoltage tolerance.
  • Input Signal: Compatible with NORIS NTC thermistors (TH.1, TH.2).
  • Output Contact: Volt-free change over switch contact, available in closed or open-circuit variants.
  • Switching Capacity: Maximum 30 W (1 A at 30 V/DC; 0.5 A at 60 V/DC) and 40 W (0.2 A at 220 V/AC).
  • Operating Temperature: -20°C to +70°C; Storage Temperature: -45°C to +85°C.
  • Protection Class: Body IP20, terminals IP00.
Features:
  • Compact construction suitable for severe operating conditions.
  • Limit value adjustable via a tamper-proof drum scale.
  • Short circuit and broken-wire monitoring with LED indicators.
  • Flame-inhibiting and self-extinguishing body.
Operational Details:
  • Relay operation is triggered when the actual value reaches the setpoint.
  • LED indicators: Green for ready-to-operate, Red for limit exceeded or fault conditions.
  • Monitoring for short circuits and circuit integrity is integrated.
Standards and Compliance:
  • Complies with CE requirements and various IEC standards for electromagnetic compatibility and environmental conditions.
  • Approved by GL, BV, LR, DNV.
Applications: Suitable for temperature monitoring in industrial environments, particularly where precise control and reliability are required.
See more

Catalog excerpts

Datasheet RH5-1

Limit-value switch for temperature, input NTC thermistor 1 2 Straightforward application Suitable for severe operating conditions Compact construction Limit value freely adjustable by drum scale Anti-tamper seal for drum scale Meet high EMC-requirements Limit-value switches Volt-free output as change over switch contact Open-circuit or closed-circuit variants available Short circuit monitoring of input signal Broken-wire monitoring of input signal Operating characteristics displayed by integrated LEDs Flame-inhibiting and self-extinguishing body Suitable temperature sensors are available Limit-value switches of series 5 Limit value switches of the series 5 are designed to monitor and process electric measured variables. Working principle: When the actual value of the measuring signal supplied reaches the setpoint, the built-in relay will operate. The switching status of the relay contact may, for instance, be monitored or individually processed by a machine controller. General notes on Type RH5.. Description RH5.. The Type RH5.. is designed for the temperature monitoring with NTC (negative temperature coefficient) thermistors whose resistance decreases as the temperature is increased. Basically, any NTC-ther- in regular operation. In the case of a wire break occurring in the sensor, the maximum value of the sensor signal will be exceeded, causing the relay mistor sensor can be used that possesses a characteristic that of NORIS sensors is recommend- ate, the red LED lights up just like when the limit value is exceeded the limit-value switches. Settings failure, the green LED will be flashing to signal a broken-wire condition. ed because they are matched to output to operate and the red LED to light up. To identify sensor of the limit value are made at the short top side of the switch by means of a drum scale. The scale is graduated in degrees Celsius to suit the specific measuring range of 40 ... 120 °C or 5 ... 70 °C. Any value on the drum scale can be selected as the limit value. Volt-free relay contact, closed-circuit or open-circuit version A volt-free relay contact is provided as a change over switch contact for outputting and further processing. In addition, there is a choice between closed-circuit and open-circuit devices. In the case of closed-circuit devices, the output relay is pulled up in the normal state of operation with the supply voltage applied. It drops off upon the limit-value being exceeded or if the supply volt- age fails. In the open-circuit variant, the output relay pulls up when the limit-value is exceeded with the supply voltage applied. Failure of the Monitoring for short circuit and circuit integrity voltage will not result in any switching function below the limit value. The RH5.. type series comes equipped for monitoring sensors for short circuits and integrity. In the event of a short circuit, the maximum limit value is exceeded

 Open the catalog to page 1
Datasheet RH5-2

Other Data Series RH5.. Relay position Type key / variants RH5..-A Input range: x = contact closed - = contact open The red LED is illuminated, if the limit value is exceeded R Limit-value switch Input signal H |NTC resistance Type series 5 Type 5

 Open the catalog to page 2

All NORIS Group GmbH catalogs and brochures

  1. Datasheet RG5

    2  Pages

  2. Datasheet FA13

    14  Pages

  3. Datasheet NIQ31

    16  Pages

  4. Datasheet FA54

    11  Pages

  5. NORIS Brochure

    15  Pages

  6. Datasheet EOT

    6  Pages

  7. Datasheet DWA

    4  Pages

  8. Datasheet VF5

    2  Pages

  9. Datasheet RF5

    2  Pages

  10. Datasheet RI5

    2  Pages

  11. Datasheet RW5

    2  Pages

  12. Datasheet VP5

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.