Datasheet NORISYS 4 LA4
4Pages

{{requestButtons}}

Catalog excerpts

Datasheet NORISYS 4 LA4 - 1

NORISYS 4 LA4 Control Lever System n Several available scales, separated for both handles n LED band for position indication of active lever for each handle n Optional electrical shaft functionality for each handle with Control lever system NORISYS4-LA4 force feedback n 2 separated CANbus interfaces (option) 1 RS-485 interface (optional) 1 scale illumination input (dimmable) 2 digital inputs, galvanically isolated (optional) 2 analogue outputs 4 ... 20 mA (handle and rotation, optional) Extended operating temperature range -25°C ... +70°C IP56 front side Application range The NORISTAR control lever system is designed for ship propulsion plant applications in accordance to marine certification requirements. The lever can be equipped in three levels, starting from a mechanical setup with potentiometric signal outputs, basic electronic equipment with analogue standard signal output 4 ... 20 mA for each handle and as full electric version with integrated data interface and optional electrical shaft system onboard. The full electronic version is equipped with several data interfaces as well as analogue standard signal outputs. The full electronic equipped control lever can be interconnected to an automation system via redundant or single CANbus as well as by using the integrated RS-485 interface with Modbus-RTU or NORISYS 4 ExtBus protocol. The electronic control lever can be used as gateway to add NORISYS 4 and NORISTAR 4 extension units to an automation system. All versions provide a signal output for each handle, positioning indication and dimming of the scale illumination. The data interfaces are short-circuit proved and 24 V protected. Description In relation to its area of application the lever can be equipped as single or double lever as well as control lever chain. The portfolio of standard and customer-specific scales matches a wide range of applications. Direct wiring of standard industrial signal cables is provided by 2.5 mm² terminal blocks. The design as a plug-and-play component in the basic and full electronic version requires no calibration handling on customer side. The full electronic version is equipped with a high performance ARM processor, which calculates the handle positions, controls the integrated LED band as well as the stepper motors of the optional electrical shaft system and powers the data interfaces. The integrated LED band for each handle is a precise visualisation to indicate the current position of the active control lever and to support the operator during control position transfer. An optional electrical shaft system provides automatic alignment of each handle according to the position of the active control lever in the network. The ESS option uses the existing network interconnection between all levers and the remote control system and requires no separate control hardware. Mechanical Versions The mechanical design allows a setup of several application specific versions. The control lever can be equipped with several mechanical lock points on rotation side and at the handle. Additionally it is possible to equip the control lever with an optional electric shaft system. Datasheet DB-NORISYS4-LA4-EN | V01.02 | 04/12/2019 | Valid from product revision Rev. M2.1 | www.noris-group.com | sales@noris-automation.de

Open the catalog to page 1
Datasheet NORISYS 4 LA4 - 2

| Dimensions, connections and drawings NORIS Automation GmbH Dimensions, connections and drawings Device dimensions Explanation to the left illustration (front view) A) Length 130.00 mm B) Length 140.80 mm C) Length 96.00 mm Explanation to the left illustration (side view) A) Thread M4, length 20.8 mm B) Thread M3, length 20.8 mm C) Length 146.5 mm Explanation to the left illustration (above view) A) Length 192.00 mm B) Length 192.00 mm Desk cut-out Explanation to the left illustration A) Length 174 mm B) Length 82 mm C) Length 164 mm D) Length 2 mm E) Length 5 mm F) Length 100 mm G) 4 x Ø...

Open the catalog to page 2
Datasheet NORISYS 4 LA4 - 3

NORIS Automation GmbH Technical data Connection Supply voltage Current consumption 0.15 ... 1.5 A according to level of equipment Reverse voltage protection Over voltage protection Interfaces CANbus (optional) Electrical connections Terminals for cable profile 2.5 mm² In-/Output Digital inputs 1 x Input, 1x Output, galvanically isolated Illumination regulation input Environmental influences Operating temperature Climatic test Storage temperature Vibration resistance IEC 61000-4-2: ± 6 kV/Contact Discharge; ± 8 kV/Air Discharge HF-interference immunity Interference emission Mechanical...

Open the catalog to page 3
Datasheet NORISYS 4 LA4 - 4

NORIS Automation GmbH Type code Type code structure LA4… LA4 Base type Scale orientation Rotary scale Control head scale design Control head scale subdesign Signal processing Illumination Options Layout Type code LA4… Base type Scale orientation Azimuth lever with rotational and thrust setpoint value -FWD Forward oriented installation Astern oriented installation Rotary scale -180 Scale marking for 90° in cw/ccw, turning range of 180° -360 Scale marking for 180° in cw/ccw, endles turning range (360°) -C Control head scale design Customer-specific scale and turning range, e.g. +/-35° /0-10...

Open the catalog to page 4

All NORIS Group GmbH catalogs and brochures

  1. Datasheet FA13

    14 Pages

  2. Datasheet FA54

    11 Pages

  3. NORIS Brochure

    15 Pages

Archived catalogs