1. Catalogs
  2. NORIS Group GmbH
  3. Datasheet NORISPEED FMN6

Datasheet NORISPEED FMN6

Datasheet NORISPEED FMN6

Datasheet NORISPEED FMN6

Product catalog summary
Overview: The document describes the NORISPEED multifunctional device, designed for speed measurement and rotational direction detection, with capabilities for slip and offset measurement. It processes measurement values into electrical norm signals and is suitable for various industrial applications.
Key Features:
  • Slip Measurement: Evaluates the difference between two speed signals, with deviations monitored via programmable digital outputs.
  • Offset Measurement: Compares measured speed with a programmable reference, providing outputs as analogue values.
  • Digital Outputs: Includes programmable relay outputs for firing speed, rated speed, and overspeed, with status indicated by LEDs.
  • User Guidance: Parameter settings via device buttons and visualisation on an integrated display, showing speed signals and status in plain text.
  • Application Flexibility: Measures up to two speed signals with slip and offset measurement, direction detection, and programmable speed range.
  • Signal Outputs: Configurable norm signal outputs (0...5 V, 0...10 V, etc.) and potential-free relay outputs.
  • Robust Design: Aluminium housing for mounting rail installation, with short-circuit and overvoltage proof outputs.
Technical Specifications:
  • Supply Voltage: 24 VDC, with reverse and overvoltage protection.
  • Input Signal: Compatible with PNP, NPN, or PushPull output, with a measurement range of 1 to 12,000 Hz.
  • Output: Voltage range of -10 to +10 VDC, current output of 0 to 20 mA, with high accuracy and temperature stability.
  • Environmental Resistance: Operating temperature from -20°C to +70°C, vibration and shock resistance, and IP40 protection.
  • Approvals: CE, ABS, BV, DNV, GL, LR, NK, with fire protection class V0.
Applications: Suitable for industrial environments requiring precise speed measurement and control, with robust design and flexible configuration options.
See more

Catalog excerpts

Datasheet NORISPEED FMN6-1

NORISPEED - Multifunctional Device for Frequency Input, NORIS Standard Signal NORIS Wide range of application via flexible parameterisation Measurement of up to 2 speed signals with slip and offset measurement Direction of rotation detection Free programmable speed range 2 galvanically isolated norm signal outputs, configurable as: 0...5 V, 0...10 V, 2...10 V, +/-5 V, +/-10 V, 4...20 mA or 0...20 mA 6 potential-free relais outputs with normally open switch Short-circuit- and overvoltage proof outputs Operational status LED Wire-break monitored inputs Integrated display for indication and parameterising Robust aluminium housing for mounting rail installation Multifunctional Device FMN6... General Functionality The multifunctional device is designed for speed measurement and rotational direction detection with slip- as well as offset measurement and processing the measurement values into electrical norm signals. Speed Measurement and Signal Processing The multifunctional device NORISPEED detects the impuls signal and converts it into a speed proportional analogue signal. The pick-ups are supplied with the internal supply voltage of the multifunctional device. Additionally, specific speed ranges can be monitored and evaluated via digital outputs by a master controller. Therefore the device is equipped with potential free switching outputs for rotational direction, firing speed, nominal speed, over speed and device status. For easy operation NORISPEED has four buttons and a front display. It will be installed on top-hat rail. By default, the multifunctional device NORISPEED is able to measure up to two speed signals simultaneously and process them as analogue norm signals, configurable as 0...5 V, 0...10 V, 2...10 V, +/-5 V, +/-10 V, 4...20 mA or 0...20 mA. In addition to the standard operation the direction of rotation detection, a slip measurement or an offset measurement is possible. All outputs are galvanically isolated to each other and to the supply voltage. Direction of Rotation Detection NORISPEED can also be used to detect the direction of rotation. Therefore both input channels are used at two radially offset pick-ups. The direction of rotation is indicated by the relay outputs „L" and „R". All analogue and digital outputs are available in this mode. Slip Measurement Furthermore NORISPEED can be used for slip measurement. In this mode a difference of the two speed signals is determined which can be evaluated. The speed deviation can be monitored at the programmable digital outputs. Offset Measurement When used for the offset measurement, the measured speed will be compared with a programmable speed reference and can be monitored as an analogue value (e. g. for accurate monitoring of a defined speed). The scaling of the speed deviation is parameterisable. It is provided on the analog and digital outputs. Digital Outputs The potential free relay outputs (firing speed, rated speed, overspeed) are programmable (NO/NC). The correct function of the device is indicated by the closed status relay. Additionally, the status of the digital outputs is indicated by LEDs. User Guidance and Visualisation The parameter setting is realised via device buttons and the visualisation on the integrated display unit. The display shows the measured speed signals as absolute value or as a ratio (in percentage). The status is indicated as plain text with the number of errors that occurred.

 Open the catalog to page 1
Datasheet NORISPEED FMN6-2

Technical Data Dimensions, Connection, Diagram Series FMN6.. Type Code/Standard Variants FMN6 1 Device and series Multi functional device with frequency input for NORIS standard signal; model extruded profile L x H = 105 x 24 (40) mounting rail TS35, connection via terminal block Model Length 107 mm, with 2 terminal blocks, 12-pole K Plug with spring type terminals NORIS Automation GmbH | Friedrich-Barnewitz-Strasse 10 | 18119 Rostock | Germany | Phone: +49 381 519944-0 | Fax: +49 381 519944-4 | [email protected] | www.noris-group.com DB-FMN6_en V02.02 - 01/2013 - Errors and omissions...

 Open the catalog to page 2

All NORIS Group GmbH catalogs and brochures

  1. Datasheet RG5

    2  Pages

  2. Datasheet FA13

    14  Pages

  3. Datasheet NIQ31

    16  Pages

  4. Datasheet FA54

    11  Pages

  5. NORIS Brochure

    15  Pages

  6. Datasheet EOT

    6  Pages

  7. Datasheet DWA

    4  Pages

  8. Datasheet VF5

    2  Pages

  9. Datasheet RF5

    2  Pages

  10. Datasheet RI5

    2  Pages

  11. Datasheet RH5

    2  Pages

  12. Datasheet RW5

    2  Pages

  13. Datasheet VP5

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.