Datasheet NIR3 NIQ3
20Pages

{{requestButtons}}

Catalog excerpts

Datasheet NIR3 NIQ3 - 1

Type NORIMETER 3 analogue indicator with stepper motor technology, universally applicable Construction type Round type NIR3; square type NIQ3 Stepper motor principle Housing sizes Protection class IEC 60529: Front of housing IP66, IP67 and IP68 (1 m, 24 h); rear of housing IP30 (standard, higher on request) Measured variables Analogue measurement signals (Voltage, current), Frequency signals, Resistive sensor signals (Pt100/Pt1000, NTC thermistor, resistance) Scale angular With pointer up to max. 300° (standard 240°) Housing material Glas fibre reinforced, salt spray resistant and uv stabilised plastic; upper part: PC GF10; base plate: PC GF30; face made of lumenized float glass Externally dimmable LED illumination Supply voltage 18 ... 36 VDC, other voltages on request Fire protection Display principle Special features NORIMETER 3 indicators are mainly used in the Shipbuilding industry, transport technology and mechanical engineering. The indicators fulfill the requirements of the DIN EN 50155 for railway technology and of common ship classification societies and thus, are suitable for applications in harsh environments. Thanks to the mechanical construction, the housing is highly resistant against salt spray and thus, outdoor use is possible. The DIN-compliant housing sizes are suitable for installation in control cabinets and control panels with pre-stamped standardised installation openings. • Indicator with non-linear scales (spreading scale) available • Long lifetime due to compact and robust technology, a high protection class and a glass-fibre-reinforced, salt spray resistant plastic housing, suitable for outdoor areas • Individual scale design and corporate logos possible, even for small quantities • Option: Available as indicator with 360° rotary faceplate (see datasheet DB-NIQ31) or as indicator with frequency input with integrated direction-of-rotation monitoring • Option: Minimum-Maximum value indication for saving and indicating the highest and lowest measured value Display principle The display on the NORIMETER 3 is via a high-resolution stepper motor with integrated precision transmission at a resolution of 12 steps per degree. A display with a 240° standard scale thus achieves a resolution of the measuring signal in 2880 display steps. The motor itself has a mechanical transmission end stop and an angle of rotation of 315°. This makes a scale angle of up to 300° possible. In addition, a display with a 360° rotating faceplate is available (see data sheet DB-NIQ31). • Option: Control functionality for sensor failure and power supply failure (Live-Zero) • Connection for external illumination control as well as separate default brightness setting. On devices with an illuminated pointer it is also possible to set the pointer lighting separately. The motor is controlled by the firmware via a digital filter. This results in an optimum combination of smooth adjustment of the measure value and high precision (without the pointer wavering). The transmission backlash is almost halved by the firmware. This measure allows a display accuracy greater than 0.5% to be achieved relative to the measuring range. Datasheet DB-NIR3/NIQ3-EN | V01.07 | 07/05/2021 | Valid from product revision Rev.A | www.noris-group.com |

Open the catalog to page 1
Datasheet NIR3 NIQ3 - 2

NORIS Automation GmbH Content Display versions [} 3] Zero point, pointer return point and measuring range [} 6] Lighting [} 6] Line compensation for temperature display [} 7] Monitoring functions [} 7] Optional special functions [} 8] Signal LED and flashing pointer [} 8] Line compensation [} 8] Min/max display [} 9] Limit value switch output [} 9] Motor with anti-clockwise rotation [} 9] Dimensioned drawing, connection diagrams and circuit diagrams [} 12] Technical data [} 15] Type code [} 17] Scale design - order assistance [} 19] NORIS Automation GmbH | Muggenhofer Str. 95 | 90429...

Open the catalog to page 2
Datasheet NIR3 NIQ3 - 3

NORIS Automation GmbH Indicator versions The following figures show the indicator types and sizes: Housing sizes for Type NIR3 with round design From left to right: Type NIR3 Ø 60 mm, Ø 80 mm, Ø 100 mm, Ø 130 mm Housing sizes for Type NIQ3 with square design From left to right: Type NIQ3 72x72 mm, 96x96 mm, 144x144 mm NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted

Open the catalog to page 3
Datasheet NIR3 NIQ3 - 4

NORIS Automation GmbH Standard version Scale and pointer The markings and the graduation of the scale are in accordance with DIN43802 and DIN43780 but can also be customer-specific on request. Scale and pointer – standard versions (in acc. with DIN 43802 and DIN 43780) White scale dial Scaling and scale markings Black scale dial Coarse-fine graduation Scale dial illumination Scale dial illumination, white White illumination of scaling and scale markings Pointer versions Black pointer, unlit Illuminated pointer: white, red when lit Scale – individual versions Scale and scale markings...

Open the catalog to page 4
Datasheet NIR3 NIQ3 - 5

NORIS Automation GmbH Example of scales, standard and custom versions Round design, Type NIR3 Fig. 1 YOUR LOGO Square design, Type NIQ3 NORIS Automation GmbH | Muggenhofer Str. 95 | 90429 Nuremberg | Germany | Tel: +49 911 3201-220 | Fax: +49 911 3201-150 | sales@noris-group.com | www.noris-group.com Errors and omissions excepted

Open the catalog to page 5
Datasheet NIR3 NIQ3 - 6

NORIS Automation GmbH Zero point, return point and scale measuring range Scale zero point The position of the scale zero point can be specified as required. Scale zero point on the right (Standard) Return point Scale zero point: customer-specific Scale zero point in the middle (Standard) • When the power is off, the pointer turns to the return point. • The position can be specified as required. • The return point must not be the zero point (e.g. to allow power failures to be detected in the live zero function) Measuring range Scale spread • Note the difference between the printed measuring...

Open the catalog to page 6