Datasheet EOT
6Pages

{{requestButtons}}

Catalog excerpts

Datasheet EOT - 1

NORISTAR EOT Emergency Order Telegraph NORISTAR EOT Emergency Order Telegraph The NORISTAR EOT emergency order telegraph is an emergency communication system between the wheelhouse and engine room for transmitting basic commands quickly and reliably. General Function Each EOT module is equipped with 11 command push-buttons. The EOT is mounted in a panel cut-out and interconnected via CANbus. Three different types of EOT panels are available: a master module for the bridge and astern bridge respectively and a slave module for the engine room or engine control room. When a command push-button (e. g. on the bridge EOT) is pressed, the connected EOT panels indicate the command visually and acoustically: the relevant command push-button flashes and an integrated buzzer is activated at the same time. The operator has to acknowledge the command at the receiving EOT by pressing the flashing command push-button. EOT Illumination and Engine Order Announcement The neutral background illumination is blue. The command push-buttons light up green to indicate when ahead commands are active and red to indicate when astern commands are active. The command status is indicated by a flashing light (for unacknowledged commands) or a steady light (for acknowledged commands). Furthermore, all the inscription on the EOT panels is illuminated. In addition, the bridge EOT has an integrated dimmer function for adjusting the illumination. The illumination functionality can be tested by performing a lamp test. Failure Monitoring and Alarm Indication The proper operation of the EOT system is monitored and indicated by an illuminated operating status field and a system failure field on each EOT. A flashing code provides information about any failures that occur. Furthermore, a system analysis is performed via an RS-232 interface to read out system failures. All NMEA datasets and alarms contain a time stamp which is created by an internal real-time clock or an external ship clock signal. Alarms are stored in a ring buffer and can be accessed via the serial port interconnection. Operation with Several EOTs The EOT system can manage up to 12 telegraph modules. Up to 6 modules can operate on the bridge side plus another 6 on the engine side. Each EOT has 6 potential-free relay outputs, e. g. for failure, wrong way alarm, or connection of an external buzzer or an external flashlight. It also has two galvanically isolated binary inputs, e. g. for switching between two bridge EOT systems. Communication with a Voyage Data Recorder (VDR) is achieved in accordance with the IEC61162-1 standard using a galvanically isolated RS-422/485 serial interface. Datasheet DB-EOT-EN | V03.00 | 02/03/2015 | Valid from product revision Rev. i05 | www.noris-group.com | sales@noris-automation.de

Open the catalog to page 1
Datasheet EOT - 2

| Dimensions, connections and drawings NORIS Automation GmbH Dimensions, connections and drawings Device dimensions and connections Explanation to the left illustration A) Length 126 mm B) Length 127 mm C) Length 144 mm D) Length 9 mm E) Length 218 mm F) Length 234 mm G) Length 252 mm H) Diameter Ø 4 mm Explanation to the left illustration (side view) A) Length 19.20 mm B) Length 19.80 mm C) Length 24.20 mm D) Length 5 mm DB-EOT NORIS Automation GmbH | Friedrich Barnewitz Str. 10 | 18119 Rostock | Germany | Tel: +49 381 519 944-0 | Fax: +49 381 519 944-4 sales@noris-automation.de |...

Open the catalog to page 2
Datasheet EOT - 3

NORIS Automation GmbH Dimensions, connections and drawings | Panel types Front panel EOT Bridge Forward Front panel EOT Engine Room / Engine Control Room Front panel EOT Bridge Astern System structure DB-EOT NORIS Automation GmbH | Friedrich Barnewitz Str. 10 | 18119 Rostock | Germany | Tel: +49 381 519 944-0 | Fax: +49 381 519 944-4 sales@noris-automation.de | www.noris-group.com Errors and omissions excepted

Open the catalog to page 3
Datasheet EOT - 4

| Technical data NORIS Automation GmbH NORIS Automation GmbH | Friedrich Barnewitz Str. 10 | 18119 Rostock | Germany | Tel: +49 381 519 944-0 | Fax: +49 381 519 944-4 sales@noris-automation.de | www.noris-group.com Errors and omissions excepted

Open the catalog to page 4
Datasheet EOT - 5

NORIS Automation GmbH Technical data | NORIS Automation GmbH | Friedrich Barnewitz Str. 10 | 18119 Rostock | Germany | Tel: +49 381 519 944-0 | Fax: +49 381 519 944-4 sales@noris-automation.de | www.noris-group.com Errors and omissions excepted

Open the catalog to page 5
Datasheet EOT - 6

| Type code NORIS Automation GmbH -EOT iRECV i-BOX i-AW-FL Base type Model / Device Type Equipment option 1 Example: NORISTAR-EOT RECV-BOX-AW-FL Base type j-EOT Model / Device type Equipment option Emergency Order Telegraph Transmitter Forward facing Transmitter Astern facing Receiver (console mounting if without Equipment option 1) -BOX Receiver installed in wall mounting cabinet (standard mounting if without Equipment option 2) NORIS Automation GmbH | Friedrich Barnewitz Str. 10 | 18119 Rostock | Germany | Tel: +49 381 519 944-0 | Fax: +49 381 519 944-4 sales@noris-automation.de |...

Open the catalog to page 6

All NORIS Group GmbH catalogs and brochures

  1. Datasheet FA13

    14 Pages

  2. Datasheet FA54

    11 Pages

  3. NORIS Brochure

    15 Pages

Archived catalogs