Open the catalog to page 1Warning: Before using this product, please refer to the important safety information in the user manual and review all warnings, limitations and disclaimers. This product is no substitute for proper training and careful seamanship. Proper installation and proper use of the equipment is the responsibility of the owner to avoid accidents, personal injury or property damage. The user of this product is solely responsible for compliance with maritime safety practices. The owner is solely responsible for installing and using the equipment in a manner that will not cause accidents, personal injury...
Open the catalog to page 2The WLF-180 main control handle is suitable for single and dual main engine control in the propulsion systems of large and medium-sized ships. The product has the following characteristics: -The aluminum alloy shell allows each scale to light up separately according to the grip position. -The control damping and rotation range can be fine-tuned, meeting the requirements of electromagnetic compatibility and vibration in the IEC60945 standard. -It supports customized functions such as electric shaft synchronization and scale for each position, featuring a fashionable and elegant appearance, as...
Open the catalog to page 4According to the position of the handle, the products are divided into two main push 180D, left main push 180L and right main push 180R, as shown in Figure 1.2. When selecting, we should inform our sales staff according to personal needs to avoid unnecessary economic losses!
Open the catalog to page 5The product has a gear position indication function. The scale band has backlighting and the backlight can change along with the rotation of the handle. It provides 4-20mA analog output. The interface definition is as follows: Connect according to Figure 1.4 on the 16-bit terminal block. PI /P2 are the current outputs of the left grip, P3/P4 are the current outputs of the right grip, and PI 3/P14 are connected to the 24V regulated power supply. Standard wiring diagram
Open the catalog to page 6shaft is made of stainless steel, and internal transmission uses copper gears. 2. The gear position panel is black. The gear positions include green zones (Ahead 1, Ahead 2, Ahead 3, Ahead 4), yellow zones (DEAD SLOW, STOP, DEAD SLOW), and red zones (Astern 1, Astern 2, Astern 3, Astern 4). The gear indicator changes as the handle grip rotates, and dimming is achieved via an external dimmer. 3. Operating torque is constant. The rotational torque and detent feel are adjustable. 4. Potentiometer resistance tolerance: ±10%; independent linearity tolerance: 0.3%. 5. Output mode: 4-20 mA linear output,...
Open the catalog to page 7The analog output of the product has been calibrated at the factory and does not require calibration. However, if during operation the mechanical pointer of the propulsion lever is found to be inconsistent with the brightness indicator position, secondary calibration can be performed as follows: 1. Ensure the propulsion lever is powered on, and locate the three buttons on the circuit board of the propulsion lever, as shown in Figure 2.2:
Open the catalog to page 82. Press and hold buttons S3 and S2 simultaneously for 3 seconds to enter the left lever calibration mode; or press and hold buttons S2 and SI simultaneously for 3 seconds to enter the right lever calibration mode. 3. Ahead 4 position calibration: Operate the lever to point the pointer to the Ahead 4 scale position, then press and hold S3 for 3 seconds to complete the Ahead 4 position calibration. 4. Stop position calibration: Operate the lever to point the pointer to the Stop scale position, then press and hold S2 for 3 seconds to complete the Stop position calibration. 5. Astern 4 position...
Open the catalog to page 91. Remove the four sets of installation accessories (nuts, spring washers, flat washers), as shown in Figure 3.1. Do not remove the installation studs. Set aside 4 sets of accessories, remember not to lose. 2. As shown in 3.2, place the handle vertically in the opening of the mounting plate, and align the screw with the screw hole B. Rotate or tilt the handle into the protruding part. 3. Secure the handle to the mounting plate by installing studs and accessories, and tighten nut C. Make the handle and mounting plate tight and reliable. There should be no gap or shaking on the contact surface,...
Open the catalog to page 104. Install the handle to the mounting plate and connect electrical cables. After the connection is complete, ensure that the external connection is firm and reliable. 5. Check the external cables, which should be connected normally; The backlight should emit light normally; Push the handle lever, the switch can complete the normal on-off action. After commissioning, disconnect the power supply.
Open the catalog to page 11value corresponding to the push direction of the potentiometer (terminals 1 and 2) is 2.5KQ ±10%. 2. Connect the power supply, wire according to Figure 1.4, push the handle rod, and the resistance reading between terminals 1 and 2 will be the continuously linearly varying output value as shown in Figure 2.1. The backlight lamp should illuminate normally. After inspection is completed, reset the handle rod to the 0 scale mark. 3. When operating the handle for pushing and rotating, it should be done smoothly and slowly. Avoid rapid pushing or pulling, as excessive speed may cause impact and damage...
Open the catalog to page 121. If it is not used according to the requirements, the loss shall be borne by the user; Rated backlight voltage ^ 24V If the backlight is damaged due to exceeding the rated voltage, the user shall bear the responsibility. 2. In the process of use, when the output of the propulsion direction exceeds the range of 0 ~ 5K, please stop using immediately; When the output value between terminals 1 and 2 cannot be continuously changed, stop using it in time. Method of stopping the service: Disconnect the external power supply. 3. According to the characteristics of the accessories used in this product,...
Open the catalog to page 13This product has been put into operation since the use, basically no fault, with our statistics, the after-sales problem is basically due to wiring errors, resulting in normal use, in addition, there is no technical fault. Customers in the use of the process, if you find technical problems, please promptly communicate with our technical personnel. (Note: Each handle has a unique factory number)