User manual Ningbo SHANBEI Technology Co.,Ltd
Open the catalog to page 1Warning: Before using this product, please refer to the important safety information in the user manual and review all warnings, limitations and disclaimers. This product is no substitute for proper training and careful seamanship. Proper installation and proper use of the equipment is the responsibility of the owner to avoid accidents, personal injury or property damage. The user of this product is solely responsible for compliance with maritime safety practices. The owner is solely responsible for installing and using the equipment in a manner that will not cause accidents, personal injury...
Open the catalog to page 2The WLF-180 main control handle is suitable for single and dual main engine control in the propulsion systems of large and medium-sized ships. The product has the following characteristics: -The aluminum alloy shell allows each scale to light up separately according to the grip position. -The control damping and rotation range can be fine-tuned, meeting the requirements of electromagnetic compatibility and vibration in the IEC60945 standard. -It supports customized functions such as electric shaft synchronization and scale for each position, featuring a fashionable and elegant appearance, as...
Open the catalog to page 4According to the position of the handle, the products are divided into two main push 180D, left main push 180L and right main push 180R, as shown in Figure 1.2. When selecting, we should inform our sales staff according to personal needs to avoid unnecessary economic losses!
Open the catalog to page 5The product has a gear position indication function. The scale band has backlighting and the backlight can change along with the rotation of the handle. It provides 4-20mA analog output. The interface definition is as follows: Connect according to Figure 1.4 on the 16-bit terminal block. PI /P2 are the current outputs of the left grip, P3/P4 are the current outputs of the right grip, and PI 3/PI4 are connected to the 24V regulated power supply. Standard wiring diagram
Open the catalog to page 6shaft is made of stainless steel, and internal transmission uses copper gears. 2. The gear position panel is black. The gear positions include green zones (Ahead 1, Ahead 2, Ahead 3, Ahead 4), yellow zones (DEAD SLOW, STOP, DEAD SLOW), and red zones (Astern 1, Astern 2, Astern 3, Astern 4). The gear indicator changes as the handle grip rotates, and dimming is achieved via an external dimmer. 3. Operating torque is constant. The rotational torque and detent feel are adjustable. 4. Potentiometer resistance tolerance: ±10%; independent linearity tolerance: 0.3%. 5. Output mode: 4-20 mA linear output,...
Open the catalog to page 7The analog output of the product has been calibrated at the factory and does not require calibration. However, if during operation the mechanical pointer of the propulsion lever is found to be inconsistent with the brightness indicator position, secondary calibration can be performed as follows: 1. Ensure the propulsion lever is powered on, and locate the three buttons on the circuit board of the propulsion lever, as shown in Figure 2.2: 2. Press and hold buttons $3 and $2 simultaneously for 3 seconds to enter the left lever calibration mode; or press and hold buttons S2 and SI simultaneously...
Open the catalog to page 81. Remove the four sets of installation accessories (nuts, spring washers, flat washers), as shown in Figure 3.1. Do not remove the installation studs. Set aside 4 sets of accessories, remember not to lose. 2. As shown in 3.2, place the handle vertically in the opening of the mounting plate, and align the screw with the screw hole B. Rotate or tilt the handle into the protruding part. 3. Secure the handle to the mounting plate by installing studs and accessories, and tighten nut C. Make the handle and mounting plate tight and reliable. There should be no gap or shaking on the contact surface,...
Open the catalog to page 94. Install the handle to the mounting plate and connect electrical cables. After the connection is complete, ensure that the external connection is firm and reliable. 5. Check the external cables, which should be connected normally; The backlight should emit light normally; Push the handle lever, the switch can complete the normal on-off action. After commissioning, disconnect the power supply.
Open the catalog to page 101. The initial position of the hand on the handle is in the middle {0 scale). At this time, the resistance value corresponding to the advance direction of the potentiometer (terminals 1 and 2) is 2.5KQ± 10%. 2. Switch on the power supply, connect the cables as shown in Figure 1.4, push the handle rod, and the resistance reading between terminals 1 and 2 is the output value of continuous linear change in Figure 2.1. The backlight emits normally. After the inspection is complete, place the handle lever at 0 scale. 3. The operation handle should be pushed and rotated smoothly and slowly to avoid...
Open the catalog to page 11This product has been put into operation since the use, basically no fault, with our statistics, the after-sales problem is basically due to wiring errors, resulting in normal use, in addition, there is no technical fault. Customers in the use of the process, if you find technical problems, please promptly communicate with our technical personnel. (Note: Each handle has a unique factory number)
Open the catalog to page 126.1 Safety protection devices and precautions 1. In the important position of this product, the fastening seals have been processed before leaving the factory, and shall not be disassembled without permission. If the seals are damaged, any product quality problems will be borne by the buyer. 2. The damping part used in this product is a loss part, the warranty period is 1 year, effective from the date of delivery; During the warranty period, there is a change in propulsion damping, which can not be used normally or seriously affect the operation, and we will maintain it free of charge. If damping...
Open the catalog to page 137.1 Daily maintenance and maintenance In the daily non-use state, attention should be paid to the maintenance of this product. Through maintenance, maintenance can improve the service fife of the product, the specific maintenance and maintenance methods are as follows: 1. Wipe the surface of the product regularly with a dry rag to ensure that the outside of the product is clean and tidy. 2. Disconnect the external power supply of the product, push it back and forth regularly, repeat about 10 times, and the cycle is 2 to 3 weeks. It can ensure smooth promotion and avoid the phenomenon of "aging"...