Open the catalog to page 1Warning: Before using this product, please refer to the important safety information in the user manual and review all warnings, limitations and disclaimers. This product is no substitute for proper training and careful seamanship. Proper installation and proper use of the equipment is the responsibility of the owner to avoid accidents, personal injury or property damage. The user of this product is solely responsible for compliance with maritime safety practices. The owner is solely responsible for installing and using the equipment in a manner that will not cause accidents, personal injury...
Open the catalog to page 2The WLF-100 series propulsion control handles are used for single and dual engine control, and can also be used for the control of other master devices. The product has the following characteristics: -Aluminum alloy shell, main body diameter 90mm, compact structure, compact transmission; -With light scale indicator, easy to use, flexible damping adjustment, feel comfortable; -Features Customized, built for you, options include: mounting panel, scale panel, handle grip lever, potentiometer level, embedded switch, motor drive, front drive, rear drive, etc., as shown in Table 1.1. Base customization...
Open the catalog to page 4According to the position of the handle, the product is divided into two main push 100D, left main push 100L and right main push 100R, as shown in Figure 1.2. When selecting, we should inform our sales staff according to personal needs to avoid unnecessary economic losses! 1.3 Product composition Number
Open the catalog to page 51.5 Product wiring diagram Each side of the handle provides a separate PCB board, although this is a multi-in-one circuit board, but the production has been fixed in accordance with the requirements of the order to solidify the function (including output signal and dimming signal), each side contains 16 terminals, where P1-P3 is the potentiometer output signal (if any), P4~P5 is the output of 4~20mA (if any), P6 to P7 are commissioning ports, P11 to P12 are dimming ports, and P13 to P14 are DC24V power ports.
Open the catalog to page 61. The main body of the handle is made of aluminum alloy, the surface is made of black spray plastic, the main shaft is made of stainless steel, and the interior is driven by copper gear; 2. The scale range is 100-0-100, the background color is green before and red after, the scale line and digital white, the backlight is always on, and the brightness can be adjusted through an external dimmer; 3. Constant operating torque, adjustable rotating torque and caton point feel; 4. Resistance tolerance of potentiometer ±10%, independent linear tolerance 1.0%; 5. Output mode: direct potentiometer linear...
Open the catalog to page 72. Rotation range: The rotation range of the handle can be ±60°, 0-60°, or -1 5-60°. The default is ±60°, as shown in Figure 2.3.
Open the catalog to page 8In general, the corresponding relationship of output signals is as follows: scale -100% corresponds to 4mA output, scale 0 corresponds to 12mA output, and scale +100% corresponds to 20mA output, as shown in Figure 2.5. For the need to collect the handle ahead, stopping, reversing signals, you can also choose the corresponding module to achieve passive switch contact output, single push or double push handle can be configured, the module can be configured according to the need to configure 1~3 limit switches (brand: Japan Omron), output normally open or normally closed signals. The size of the...
Open the catalog to page 9For 0-24V dimming signals, the dimming signal is the darkest at OV and the brightest at 24V. Note that the dimming signal and the power signal cannot be shared, otherwise the handle signal output will be affected, resulting in failure to work normally. The connection diagram is shown in Figure 2.7: Please consult our sales staff to determine the selection of PWM dimming interface signal. 4 to 20mA output wiring diagram lout+ lout- Each handle provides 16 terminal connections. Terminal 1/2/3 output handle potentiometer signal is used to calculate the current Angle; Terminal 10/11/12 connected...
Open the catalog to page 101. Remove the four sets of installation accessories (nuts, spring washers, flat washers) as shown in Figure 3.1. Do not remove the installation studs. Set aside 4 sets of accessories, remember not to lose. 2. Place the handle vertically in the opening of the mounting plate as shown in the lower right corner of Figure 3.2, and align the screw with the hole B. Rotate or tilt the handle into the hole when it meets the protruding part. 3. Secure the handle to the mounting plate by installing studs and accessories, and tighten nut C. Make the handle and mounting plate tight and reliable. There should...
Open the catalog to page 114. After the handle is installed on the mounting plate, Figure 2.5 shows the electrical cables. After the wiring is completed, it should be confirmed that the external wiring is firm and reliable. 5. Check the external cables, which should be connected normally; The backlight should emit light normally; Push the handle lever, the switch can complete the normal on-off action. After commissioning, disconnect the power supply.
Open the catalog to page 121. The initial position of the hand on the handle is in the middle (0 scale). At this time, the resistance value corresponding to the advance direction of the potentiometer (terminals 1 and 2) is 2.5KQ± 10%. 2. Switch on the power supply, connect the cables as shown in Figure 1.5, push the handle rod, and the resistance reading between terminals 1 and 2 is the output value of continuous linear change in Figure 2.1. The backlight emits normally. After the inspection is complete, place the handle lever at 0 scale. 3. The operation handle should be pushed and rotated smoothly and slowly to avoid...
Open the catalog to page 13This product has been put into operation since the use, basically no fault, with our statistics, the after-sales problem is basically due to wiring errors, resulting in normal use, in addition, there is no technical fault. Customers in the use of the process, if you find technical problems, please promptly communicate with our technical personnel. (Note: Each handle has a unique factory number)