Ningbo SHANBEI Technology Co.,Ltd
Open the catalog to page 1Warning: Before using this product, please refer to the important safety information in the user manual and review all warnings, limitations and disclaimers. This product is no substitute for proper training and careful seamanship. Proper installation and proper use of the equipment is the responsibility of the owner to avoid accidents, personal injury or property damage. The user of this product is solely responsible for compliance with maritime safety practices. The owner is solely responsible for installing and using the equipment in a manner that will not cause accidents, personal injury...
Open the catalog to page 2WEI & WSI series instruments are newly developed digital instruments, installed on the bridge control console, used to display speed, rudder Angle, power, azimuth and other information. Among them, the WEI series electromagnetic induction bridge instrument uses a moving coil movement to measure the microampere current according to the principle of electromagnetic induction. WSI series stepper motor bridge instruments, driven by instrument motor, indicate accuracy up to 0.5, shorten response time and do not overshoot the pointer. Depending on the indication requirements, the pointer can be rotated...
Open the catalog to page 4The product backlight adopts DC24V power supply, and other voltage levels are strictly prohibited. Remove the protective cover from the back of the meter and connect cables based on the following figure. Fork or round cord end terminals are recommended to ensure reliable cable connection. Tighten and reinstall the protective cover. 1. The WEI series has four wiring terminals, in which the input signal is connected to 2 and 5, and the power supply is connected to 8 and 11. If the backlight of the instrument needs to be adjusted, a dimmer (resistance value 250K) needs to be connected in series....
Open the catalog to page 61. Open the hole in the predetermined position according to the size, remove the protective cover, and loosen the ejector nut; 2. As shown in Figure 3.1, put on the rubber gasket, install the instrument A to the mounting surface B through the ejector rod and nut, and tighten the nut to ensure secure. 3. Cover the transparent sealing cover to protect the front of the instrument.
Open the catalog to page 81. With backlight function, it can collect DC0-10V voltage or DC4-20mA current signal, 360° indication, zero point and full point overlap, zero point can be set at 12 o 'clock position, or set at 6 o ’clock position. 2. The instrument has two analog input modes, in which input 1 corresponds to the indicator in the clockwise direction, input 2 corresponds to the indicator in the counterclockwise direction. Ordering is selecting one of the input methods. 3. With self-test function Press the button after the instrument to self-test, and the instrument will self-test when powered on. 4. For WEI electromagnetic...
Open the catalog to page 9This product has been put into operation since the use, basically no fault, with our statistics, the after-sales problem is basically due to wiring errors, resulting in normal use, in addition, there is no technical fault. Customers in the use of the process, if you find technical problems, please promptly communicate with our technical personnel.
Open the catalog to page 106.1 Safety protection devices and precautions 1. In the important position of this product, the fastening seals have been processed before leaving the factory, and shall not be disassembled without permission. If the seals are damaged, any product quality problems will be borne by the buyer. 2. Once the product fails to operate normally, please stop using and disconnect the power supply immediately, and contact our after-sales service engineer for a solution. 6.2 Troubleshooting procedures and methods 1. In the process of use, there is an unsolvable fault problem, contact our after-sales service...
Open the catalog to page 117.1 Daily maintenance and maintenance In the daily non-use state, attention should be paid to the maintenance of this product. Through maintenance, maintenance can improve the service fife of the product, the specific maintenance and maintenance methods are as follows: 1. Wipe the surface of the product regularly with a dry rag to ensure that the outside of the product is clean and tidy. 1. Stop using the device when the value of the instrument is not accurate. Contact our after-sales engineer. 2. The input voltage shall be carried out in strict accordance with the wiring instructions. Failure...
Open the catalog to page 12Physical damage to the product caused by violent shaking and collision should be avoided during transportation. Room temperature, dry, cool environment. Avoid high temperature exposure or low temperature freezing, which will cause irreversible damage to the damping parts and reduce the service life. The warranty period of this product is 12 months from the date of receipt of the goods by the buyer. Based on the date of receipt of documents for express delivery or the date of receipt of invoice.
Open the catalog to page 139.1 Phone number of the after-sales engineer Manufacturer: Ningbo SHANBEI Technology Co., LTD Address: A2-902, R&D Park, High-tech Zone, Ningbo Postal Code: 310001 Tel: (0574) 87182781 Fax: (0574) 87182781
Open the catalog to page 14For more information, please visit: www.shanbei-tech.com Ningbo SHANBEI Technology Co.,Ltd Add: 902 Area A, R&D Park, High-tech Zone, Ningbo, Zhejiang, China Tel: 0574-87186781 /18067343163
Open the catalog to page 15