1. Catalogs
  2. Nemo Power Tools
  3. CE BATTERY CELLS 4
video corpo

CE BATTERY CELLS 4

CE BATTERY CELLS 4
1 / 36 PagesView full catalog

CE BATTERY CELLS 4

Product catalog summary
Test Report Overview:
This document is a test report for secondary cells and batteries containing alkaline or other non-acid electrolytes, focusing on safety requirements for portable sealed secondary cells and batteries used in portable applications. The report is issued by JIANGSU SUNPOWER CO., LTD, with testing conducted by Shanghai Truron Testing Technology Co., Ltd.
Specifications:
  • Standard: EN 62133: 2013 (Second Edition)
  • Test Item Description: Li-ion Cell
  • Model/Type Reference: INR18650-1300, INR18650-1500, INR18650-2000, INCMR18/65
  • Ratings: 3.7Vdc with varying mAh capacities
Testing Procedures and Locations:
Testing was conducted at Shanghai Truron Testing Technology Co., Ltd. The procedures included continuous charging, external short circuit, free fall, thermal abuse, crush, forced discharge, transport tests, and forced internal short circuit.
Key Test Results:
  • Continuous Charging: Cells were tested for continuous charging at constant voltage.
  • External Short Circuit: Cells were subjected to external short circuit conditions.
  • Thermal Abuse: Cells were tested for thermal abuse to ensure safety under high temperatures.
  • Crush and Forced Discharge: Cells were crushed and forced to discharge to test durability and safety.
Compliance and Recommendations:
  • The cells comply with the specified safety standards and are designed to prevent abnormal temperature rise conditions.
  • Recommended charging method involves charging the cell with 0.2C constant current, then 4.2V constant voltage until current reduces to 0.02C at ambient 20℃±5℃.
  • Upper limit charging voltage per cell is 4.25Vdc, with maximum charging currents specified for each model.
General Safety Considerations:
  • Insulation and wiring are sufficient to withstand maximum anticipated current, voltage, and temperature requirements.
  • Battery cases incorporate a pressure relief mechanism to prevent rupture, explosion, and self-ignition.
  • Terminals have clear polarity markings and are designed to minimize the risk of short circuits.
Quality Assurance:
The manufacturer has implemented a quality plan that defines procedures for the inspection of materials, components, cells, and batteries, covering the entire production process.
Conclusion:
The test results indicate that the tested Li-ion cells meet the safety requirements outlined in EN 62133: 2013. The report confirms compliance with the necessary safety standards, ensuring the cells' suitability for use in portable applications.
Overview: This document is a technical report on the testing of Li-Ion cells, specifically models INR18650-1300, INR18650-1500, and INR18650-2000, in accordance with IEC 62133 standards. It includes various tests such as charging at temperature limits, external short circuit, crush, over-charging, forced discharge, and forced internal short circuit.
Specifications:
  • Cell Models: INR18650-1300, INR18650-1500, INR18650-2000
  • Capacity: 1300/1500/2000mAh
  • Standard Charging Current: 0.2C5A
  • Standard Full Charging Voltage: 4.20V
  • Maximum Charging Current: 1C5A
  • Maximum Charging Voltage: 4.20V
  • Standard Discharging Current: 0.5C5A
  • End Point Voltage: 2.75V
  • Maximum Discharge Current: 10C5A
  • Upper Limit Charging Voltage: 4.25V
  • Charging Temperature Limits: 45℃ (upper), 0℃ (lower)
Test Results:
  • Charging at Temperature Limits: Cells were tested at both upper (45℃) and lower (-5℃) temperature limits. All samples showed no fire or explosion (denoted as 'A,E').
  • External Short Circuit: Not applicable (N/A) for this report.
  • Crush Test: Conducted on all models at upper temperature limit. Results indicated no fire or explosion (denoted as 'A,D,G').
  • Over-Charging: Not applicable (N/A) for this report.
  • Forced Discharge: Conducted on all models with no fire or explosion observed (denoted as 'A').
  • Forced Internal Short Circuit: Conducted at ambient temperatures of 45℃ and 10℃. All samples showed no fire or explosion (denoted as 'A').
Supplementary Information:
  • Test results are categorized as: A – No fire or explosion, B – Fire, C – Explosion, D – Others (please explain).
  • Crush direction and particle location details are provided for internal short circuit tests.
Enclosures:
  • Overall views and specifications of the Li-Ion cells.
  • Outline dimensions and manufacturer date code details.
  • Packaging illustrations.
See more

Catalog excerpts

CE BATTERY CELLS 4-1

Test Report issued under the responsibility of: Truron Testing TEST REPORT Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications

 Open the catalog to page 1
CE BATTERY CELLS 4-3

National Differences ( 0 page) - 8.2.1 Continuous charging at constant voltage (cells) - 8.3.1 External short circuit (cells) - 8.3.4 Thermal abuse (cells) - 8.3.7 Forced discharge (cells) - 8.3.8 Transport tests (cells) - 8.3.9 Forced internal short circuit (cells) Shanghai Truron Testing Technology Co., Ltd. Floor 3, Building 2, No. 135, Handan Road, Shanghai, China

 Open the catalog to page 3
CE BATTERY CELLS 4-4

Copy of marking plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. INR18650-1300

 Open the catalog to page 4
CE BATTERY CELLS 4-5

lithium systems solid polymer point is used as the decimal separator. When differences exist; they shall be identified in the General product information section. TRF No. I

 Open the catalog to page 5
CE BATTERY CELLS 4-6

ZhiFu Road, Huangqiao Industrial Park, Taixing City, JiangSu province,P.R. China General product information: - The cell consists of the positive electrode plate, negative electrode plate, separator, electrolyte and case. The positive and negative electrode plates are housed in the case in the state being separated by separator. - The main features of the cell is shown as below(clause 8.1.1): - Operating Temperature: Charge: 0~45°C; Discharge: -10~60°C; - INCMR18/65 is IEC 62133 model designation and identical to models INR18650-1300, INR18650-1500, INR18650-2000 except for model designation.

 Open the catalog to page 6
CE BATTERY CELLS 4-28

Supplementary information: 1: Nickel particle inserted between positive and negative (active material) coated area. 2: Nickel particle inserted between positive aluminium foil and negative active material coated area. A - No fire or explosion B - Fire C - Explosion D - Others (please explain)

 Open the catalog to page 28
CE BATTERY CELLS 4-35

Manufacture Date: MMDDYY: MM: Mouth, 2digits, 01~12, 01represent January, and so on DD: Day, 2digits, 01~30 YY: Year, 2digits, 12 represent 2015, and so on

 Open the catalog to page 35

All Nemo Power Tools catalogs and brochures

  1. GRABO®

    1  Page

  2. HAVS REPORT

    4  Pages

  3. IEC 61558

    1  Page

  4. NPT CATALOG

    18  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.