Overview

This document provides detailed technical data for a range of multitubular heat exchangers designed for oil/water cooling applications using untreated water or seawater. The models covered include E065, E083, E110, and E135 series, each available in different configurations and options.

1. Product Description and Application

These multitubular heat exchangers are intended for cooling oil with water, suitable for untreated or seawater sources. They feature a shell-and-tube design with oil/water flowing through the outside tubes and water flowing inside the tubes.

2. Models and Variants

  • E065 Series: Available in 2-pass and 4-pass cold side configurations, with maximum water flow rates of 30.6 L/min and 60 L/min respectively.
  • E083 Series: Also offered in 2-pass and 4-pass versions, supporting water flow rates up to 150 L/min.
  • E110 Series: Available in 2-pass and 4-pass configurations, with maximum water flow rates up to 280 L/min.
  • E135 Series: Larger models with 2-pass and 4-pass options, supporting water flow rates up to 460 L/min.

3. Key Technical Specifications

ParameterTypical ValuesNotes
Core Diameter (mm)Ranges from 161 to 283Varies by model
Core Length (mm)Ranges from 100 to 526Varies by model and configuration
Heat Transfer Area (m²)0.15 to 2.74Depends on model and tube arrangement
Maximum Working Pressure (bar)2.8 to 24.2Higher pressures for larger models
Maximum Working Temperature (°C)Not explicitly stated, typical for oil/water exchangersRefer to manufacturer for exact limits
Maximum Water Flow Rate (L/min)30.6 to 460Varies by model and pass configuration
Number of Passes (Cold Side)2 or 4Determines flow path and performance
Tube MaterialCopper or Copper-NickelOptions available depending on application
Connections (Hot/Cold Side)Rp 1/2", Rp 3/4", Rp 1", Rp 1 1/2"Varies by model

4. Materials and Components

  • Tubes and Tube Plates: Brass or copper-based materials.
  • Baffles: Anodized aluminium.
  • Shell and Cover: Brass or bronze options.
  • O-rings: Viton for sealing.
  • Options: Drain on hot side, zinc anodes on cold side for corrosion protection.

5. Dimensions and Weight

Dimensions vary by model and configuration, with core lengths ranging approximately from 100 mm to over 500 mm. Weights range from around 2.8 kg for smaller models to over 24 kg for larger units.

6. Options and Accessories

  • Drain on Hot Side (D): Facilitates draining of the hot fluid side.
  • Zinc Anodes (AA): Two zinc anodes on the cold side for corrosion protection.
  • High Flow (H): Option for increased flow on the hot side.
  • Material Options: Copper or Copper-Nickel tubes, bronze covers.

7. Performance and Usage Recommendations

The heat exchangers are designed for efficient cooling of oil by water, with untreated or seawater as the cooling medium. Selection of model and configuration should consider maximum flow rates, pressure limits, and temperature requirements. Material options and accessories should be chosen based on the operating environment, especially for corrosion resistance.

8. Summary of Critical Parameters

  • Maximum working pressure ranges from 2.8 to 24.2 bar depending on model.
  • Maximum water flow rates vary from 30.6 L/min to 460 L/min.
  • Tube materials and sealing components are selected to optimize durability and performance.
  • Multiple pass configurations allow customization of flow and heat transfer efficiency.

9. Manufacturer and Version

Produced by Mota Industrial Cooling, version dated 02/2021. For further details and options, refer to www.motaindustrialcooling.com.

See more

Catalog excerpts

MOTA_E-range-1

TECHNICAL DATA MULTITUBULAR HEAT EXCHANGER Oil / Water E065 - xxx - 4 Outside tubes: oil / water Inside tubes : water Hot side: Rp 3/4" Cold side: Rp 1/2" Cooling of oil / water by untreater water or sea water Core length Number of passes on cold side Tubes material - Copper CN Copper-Nickel mnta INDUSTRIAL COOLING

 Open the catalog to page 1
MOTA_E-range-2

MULTITUBULAR HEAT EXCHANGER Oil / Water E065 - xxx - 2 Core length [mm] Core length Number of passes on cold side Tubes material - Copper CN Copper-Nickel Covers material BR Bronze Drain on hot side D With drain Anodes on cold side AA With 2 anodes mnta INDUSTRIAL COOLING

 Open the catalog to page 2
MOTA_E-range-3

TECHNICAL DATA MULTITUBULAR HEAT EXCHANGER Oil / Water E083 - xxx - 4 Core length Number of passes on cold side / [77] Tubes material - Copper CN Copper-Nickel mnta INDUSTRIAL COOLING

 Open the catalog to page 3
MOTA_E-range-4

MULTITUBULAR HEAT EXCHANGER Oil / Water E083 - xxx - 2 Core length [mm] Core length Number of passes on cold side Tubes material - Copper CN Copper-Nickel Covers material BR Bronze Drain on hot side D With drain Anodes on cold side AA With 2 anodes mnta INDUSTRIAL COOLING

 Open the catalog to page 4
MOTA_E-range-5

Core diameter Tubes material - Copper CN Copper-Nickel Core length Number of passes on cold side mnta INDUSTRIAL COOLING

 Open the catalog to page 5
MOTA_E-range-6

Data Cooling of oil / water by untreater water or sea water Core length Number of passes on cold side BR AA Tubes material - Copper CN Copper-Nickel Covers material BR Bronze Drain on hot side D With drain Flow on hot side - Standard H High flow Anodes on cold side AA With 2 anodes mnta INDUSTRIAL COOLING

 Open the catalog to page 6
MOTA_E-range-7

MULTITUBULAR HEAT EXCHANGER Oil / Water E135 - xxx - 4 TECHNICAL DATA inlet / outlet hot side Outside tubes: oil / water Inside tubes : water Hot side: Rp 1" 1/2 Cold side: Rp 1" Cooling of oil / water by untreater water or sea water Core length [mm] Outside tubes Outside tubes Inside tubes Outside tubes Inside tubes Inside tubes Weight [kg] for standard version Maximum working pressure [bar] Working characteristics Maximum working temperature [°C] Maximum water flow rate Qw = 230 L/min Tube plate Anodized aluminium Core diameter Tubes material - Copper CN Copper-Nickel Core length Number of...

 Open the catalog to page 7
MOTA_E-range-8

TECHNICAL DATA MULTITUBULAR HEAT EXCHANGER Oil / Water E135 - xxx - 2 Outside tubes: oil / water Inside tubes : water Hot side: Rp 1" 1/2 Cold side: Rp 1" 1/2 Data Cooling of oil / water by untreater water or sea water Core length Number of passes on cold side -3/ 0-H-H-0-DD Tubes material - Copper CN Copper-Nickel Covers material BR Bronze Drain on hot side D With drain Flow on hot side - Standard H High flow Anodes on cold side AA With 2 anodes mnta INDUSTRIAL COOLING

 Open the catalog to page 8

All MOTA Cooling System catalogs and brochures

  1. MOTA_A-range

    5  Pages

  2. G058

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.