INTEGRATED MARINE Fire CONTROL PANEL FIRE DETECTION FIRE EXTINGUISHER SUPERVISION ENGINE AND MACHINERY SHUTDOWN

Open the catalog to page 1
Non-USCG - 2

System Overview • 12/24 VOLT DC esigned specifically as a marine D integrated fire system to work with vessels DC batteries. tandby re-chargeable 24v battery back S up available as an option. • MODULAR EXPANSION esigned as a modular system, that can D be expanded from 2 to 16 zones. • EARLY WARNING FIRE DETECTION arine approved Heat and Smoke M detectors and Manual Call Points. Supervisory PRESSURE SWITCH • NTEGRATION WITH FIRE I EXTINGUISHER ully integrates with Sea-Fire preF engineered and ‘H’ Series extinguishers to provide low pressure and discharge alarms. • ACHINERY SHUTDOWN M...

Open the catalog to page 2
Non-USCG - 4

131-500 - Control Unit The microprocessor Control Unit is the heart of the integrated system. 7 relays (rated at 16 amps each) provide for machinery shutdown when the Control Unit detects that the Sea-Fire extinguisher has discharged. For security, the Control Unit is powered from two independent battery banks. Each power input is monitored for failure. There are two inputs for monitoring the Sea-Fire extinguisher. When used in conjunction with an ‘H’ series extinguisher, the unit can monitor Discharge as well as Low Pressure. A discharge event will trigger the machinery shutdown. All...

Open the catalog to page 4
Non-USCG - 5

131-529 - Zone Identification Panel The Zone Identification Panel (ZIP) provides the user with system status and has two tactile buttons for system control. In the event of an alarm, a Zone LED will light and the internal buzzer will sound. The ZIP is customisable to be able to accommodate user defined Zone legends. The ZIP’s are connected to the Adapter panels and the Control Panel via CAT5 cable. Two ZIP’s can be fitted to each system. TECHNICAL SPECIFICATION Mechanical: Dimensions (mm): 205(W) x 135(H) x 3(D) Weight: 183g Material: F4 PCB and Polyester overlay Electrical: Connects to...

Open the catalog to page 5
Non-USCG - 6

Hochiki Detectors The FCP has been designed to operate with the Hochiki range of CDX conventional detectors. This range of detectors have been Marine approved by GL and LR. The primary detectors are a Photoelectric smoke detector and a combined ROR and fixed 90 deg heat detector. These detectors have been chosen for their accuracy and reliability and also because of aesthetic considerations. Anciliary Equipment An Interface unit (Part No. 131-499) can be used to connect any Normally Closed equipment to on of the detection zones. For example, the FCP can be used to monitor bilge alarms,...

Open the catalog to page 6
Non-USCG - 7

Operation Overview Ordering Information Fire Detection: Control Unit The FireStop FCP uses the Marine Approved Hochiki range of CDX conventional detectors. The FCP can be expanded to detect fire from 2 to 16 zones. Each zone can support two detectors. Display Panel Adapter Unit Zone Identification Panel Interface Unit In the event of a fire, the fire location will be identified on the Zone Identification Panel via a lit LED and an alarm sounding. Multiple displays can be used throughout the vessel. D CD-CE3/M Heat Detector 90C fixed rate of rise D CD-AE3/M Heat Detector 60C fixed rate of...

Open the catalog to page 7
Non-USCG - 8

Distributed worldwide by Sea-Fire Marine 9331-A Philadelphia Road Baltimore MD21237 USA Unit 2 Discovery Voyager Park Portfield Road, Portsmouth Hampshire PO3 5FN, UK Manufactured in the UK by Blue Marble Solutions Ltd.