Waster Water Kit
4Pages

{{requestButtons}}

Catalog excerpts

Waster Water Kit - 1

WASTE WATER KIT Complies with ISO 8099 STANDARD CD: 9400000547 Kit for waste water (rectangular) 47 lt. CD: 9300000550 Kit for waste water (rounded shape) 50 lt. CD: 9400000578 Kit for waste water (rectangular) 78 lt. CD: 9300000575 Kit for waste water (rounded shape) 75 lt. CD: 9400005112 Kit for waste water (rectangular) 112 lt CD: 9300000598. Kit for waste water (rounded shape) 98 lt. Superior Durability: MATROMARINE holding tank systems are molded from linear low density polyethylene (LLDP) resin. Polyethylene is best-suited for holding tank construction because of its resistance to corrosion and odor permeation, and it will last longer than the life of a typical fiberglass hull. ISO/USCG Compliant: MATROMARINE models are fully compliant with the ISO 8099:2000(E) standard . Odor-Free Design: MATROMARINE tanks have extra-heavy wall thickness to prevent odor permeation. Tanks can be fitted with an actived carbon filter that stops unpleasant odors from escaping through the holding tank vent. Multiple Tank Outlets: Most Mtromarine models are equipped with two discharge outlets. One is for connection to a deckmounted discharge fitting and one is for connection to an overboard discharge pump. Leak-Proof Design: one hose connection Matromarine holding tanks is on the top of the tank, eliminating possibility of leakage due to a faulty connection below the liquid level of the tank contents. Our unique diptube design reduces the risk of plugging while keeping the residual contents in the tank to a minimum. ISTALLATION CHOOSING A LOCATION FOR THE HOLDING TANK SYSTEM As a general rule, the waste water tank should be positioned as low in the hull as possible with all interconnecting hoses or pipes sloped to permit gravity drainage and prevent potential hose odor permeation. The holding tank must not be exposed to temperatures above 120°F (45°C). Do not place near heat sources such as engine manifolds, water heaters, generators, etc. Be certain to estimate holding tank weight when filled (typical effluent weighs about 9 lbs. per 1 gallon or 1.08 Kg per liter). Make certain to allow for total filled weight when selecting materials for mounting the tank. Also consider impact of full tank on vessel trim. PREPARING A MOUNTING SURFACE 1. Mount tank to surface that supports the entire area of the tank. 2. If required, fabricate mounting surface and toe blocks from 13 mm or 19 mm (1/2-inch or 3/4-inch) plywood. 3. Do not mount tank on projections such as screw or bolt heads, which could puncture the tank. 4. Do not allow holding tank to block free flow of bilge water. AVOIDING HOSE ODOR PERMEATION • Hose failure due to odor permeation almost always occurs in hose runs which retain sewage when the system is not in use. • Eliminate all unnecessary runs which retain trapped liquids, if possible. • Where possible, use rigid PVC pipe in sections that cannot be arranged to drain. • Simplify hose layout by removing unnecessary valves. [For specific installations, some regulations and standards may require the installation of a vented loop (anti-siphon valve), one-way valve or seacock in sewage discharge piping.]

Open the catalog to page 1
Waster Water Kit - 2

Do not restrict the ability to pull the hose or pipe. Avoid binding corners and sharp bends. Do not use wire ties to secure the hose or pipe. Support flexible hose every 12 inches (.3 m), and support rigid pipe every 5 feet (1.5 m). When creating new holes, avoid reinforcement stringers and tabs. SOLVENT BONDING FOR RIGID PIPE AND FITTINGS 1. Use PVC cleaner on both bonding surfaces. 2. Use PVC cement (must contain tetrahydrofuran) on both bonding surfaces. 3. Connect parts using a twist and hold motion until the cement is set. 4. Let the joint cure for at least four hours or according to...

Open the catalog to page 2
Waster Water Kit - 3

SPARE PARTS: ACTIVATED CARBON FILTER:CD. 9000000600 Complete filter with 3/4"nipples. Manufactured in light alloy and nylon this filter should be installed along the breather of the tank in the highest possible location. The activated carbons should not come into contact with the liquids contained in the tank or the surrounding water. MACERATOR PUMP:Toilet waste macerator pump, 20 min. rated, can discharge tanks up to 900 litres. - bronze macerator and rubber impeller discharge pump - self priming up to 0.6 mt. vertical lift. - 43 LPM output at 3 mt. total head - macerates and discharges...

Open the catalog to page 3
Waster Water Kit - 4

LK2 TYPE VDO * System and tank level indicator CD:4500000140 12/24V. Level Indicator CONTROL PANEL HOLE 50 mm. Use a diameter 48/50 mm. cylinder saw to mount the probe on the waste tank. Combination combination printed circuit coloured wires / probes coloured wires 1)YELLOW long probe = common 2)BLUE /GREEN short probe = full tank 3)WHITE long probe = half tank Black - battery Control panel leds Yellow led = half tank Green led = full tank The colour indications refer to the complete kit (control panel, wires and terminals) the standard length of which WARNING: do not short-circuit the side...

Open the catalog to page 4

All Matromarine Products catalogs and brochures

  1. Blower

    2 Pages

  2. Power Trim

    1 Pages

  3. Deck Pump

    2 Pages

Archived catalogs