POP-UP SYSTEM
4Pages

{{requestButtons}}

Catalog excerpts

POP-UP SYSTEM - 1

MATRE MASKIN' E-mail : company@matre.no www.matre.no DATA SHEET POP-UP SYSTEM FOR HELIDECK STANDARD DESIGN GENERAL DESCRIPTION The system is a compact DIFFS with pop-up nozzles and skid designed to mix foam concentrate type AFFF in to fire water carrying foam tank and proportioner. The system proportions an exact rate of foam concentrate directly to the fire water line close to the nozzles only using some of the energy in the water. Only to be hooked up to the water line and control signal from the control panel. Special designed for systems using Matre pop-up nozzles, but also suitable to be installed in other DESIGN DESCRIPTION The system can carry tanks from 2001 to 14501. Calibrated to 1% or 3% insertion rate. Inductor proportioner capacity K= 280 - 3050 using inductor size DN100 or DN150 to be calculated according to deck size, coverage requirements and pressure. Nozzles according to deck size each covering a diameter of 7 metre and with exact K-factor calculated according to proportioner performance. SYSTEM DESCRIPTION Main components are tank for foam concentrate, inductor and nozzles. The inductor will when the water flow is activated create a vacuum which sucks foam from the tank in to the water flow at a preset calibrated rate, normally 1% or 3% using 30% of the water pressure. The inductor is also calibrated to a specific flow when the water inlet pressure is at rated

Open the catalog to page 1
POP-UP SYSTEM - 2

MATRE MASKIN' E-mail : company@matre.no www.matre.no DATA SHEET POP-UP SYSTEM FOR HELIDECK An actuator valve will activate the system down during continues running of fire pumps. Foam insertion can be shut of for test run. One operation panel and one or more remote control panels can be placed indoor or outdoor according to applicable rules and requirements. Nozzles are exactly calculated according to pressure and flow to give the correct coverage. MAIN COMPONENTS • Skid for installation to the deck carrying all components. • Ventilated tank with dip stick and drain valve for foam...

Open the catalog to page 2
POP-UP SYSTEM - 3

MATRE MASKIIM' E-mail : company@matre.no www.matre.no DATA SHEET POP-UP SYSTEM FOR HELIDECK SPECIFICATION CHART 1) Tank for 10 minutes foam application.

Open the catalog to page 3
POP-UP SYSTEM - 4

MATRE MASKIIM' E-mail : company@matre.no www.matre.no DATA SHEET POP-UP SYSTEM FOR HELIDECK

Open the catalog to page 4

All Matre Maskin AS catalogs and brochures

  1. M-SKD10

    2 Pages

  2. M-SKD11

    2 Pages

  3. M-SKD20

    2 Pages

  4. M-SKD21

    2 Pages

  5. M-BP15

    2 Pages

  6. M-BP30

    2 Pages

  7. M-BP40

    2 Pages

  8. M-BP60

    2 Pages

  9. M-BWP60

    1 Pages

  10. M-WP60

    1 Pages

  11. M-TRT2-03163

    2 Pages

  12. TET4

    2 Pages