M-FOI Inductor general datasheet
10Pages

{{requestButtons}}

Catalog excerpts

M-FOI Inductor general datasheet - 1

MATRE INDUCTOR FOAM PROPORTIONERS E-mail: company@matre.no

Open the catalog to page 1
M-FOI Inductor general datasheet - 2

MATRE Foam Inductors Datasheet for MATRE© Foam Inductors The specifications and information herein are subject to change without notice.

Open the catalog to page 2
M-FOI Inductor general datasheet - 3

MATRE Foam Inductors 2 General product description Each inductor is customised to the client's requirements regarding flow and pressure. The principle of an inductor gives a specific characteristic for performance. No moving parts can change the performance. The inductor is therefore the most reliable insertion device possible. Changing of inlet flow or pressure parameter will not be possible without recalculation, change of venturi nozzle dimensions accordingly and recalibration of insertion rate. As this device sucks foam liquid from the tank by vacuum created of venturi nozzles and...

Open the catalog to page 3
M-FOI Inductor general datasheet - 4

MATRE Foam Inductors 4.2 Standard bronze housing design - flanged A complete bronze design with POM nozzles. To be calibrated to any custom required flow, pressure and insertion rate within design range. bronze BS 1400 AB2 (up to water inlet 8") Interface for water supply Interface for foam supply Design pressure Test pressure Insertion rate 1% or 3% (Tolerance according to NFPA 11) 6% (Tolerance according to NFPA 11) Flow tolerance Minimum pressure loss The specifications and information herein are subject to change without notice.

Open the catalog to page 4
M-FOI Inductor general datasheet - 5

MATRE Foam Inductors 4.3 Standard PN16 welded housing design - flanged A complete AISI 316 design with POM nozzles. To be calibrated to any custom required flow, pressure and insertion rate within design range. Optional full material documentation Characteristics Standard Options Material Stainless steel AISI 316L, POM Nozzles Interface for water supply DINPN16 Interface for foam supply BSP F Insertion rate 1% or 3% (Tolerance according to NFPA 11) Flow tolerance nominal value ±5% Minimum pressure loss 25% of inlet pressure The specifications and information herein are subject to change...

Open the catalog to page 5
M-FOI Inductor general datasheet - 6

MATRE Foam Inductors 4.4 Standard welded housing design - flanged A welded housing design with all pressurized parts of specified main material with POM nozzles. To be calibrated to any custom required flow, pressure and insertion rate within design range. Full documentation of material and welding included. Stainless steel AISI 316 Titanium Gr.2, Super Duplex Interface for water supply Interface for foam supply Design pressure Test pressure Insertion rate 1% or 3% (Tolerance according to NFPA 11) 6% (Tolerance according to NFPA 11) Flow tolerance Minimum pressure loss The specifications...

Open the catalog to page 6
M-FOI Inductor general datasheet - 7

MATRE Foam Inductors 4.5 Standard wafer design A complete wafer housing design with POM nozzles. To be calibrated to any custom required flow, pressure and insertion rate within design range. For installation between ANSI 150 lb or DIN PN16 flanges. Full material documentation included. Characteristics Standard Options Material Bronze BS 1400 LG2 Titanium Gr2, Super Duplex, Bronze, Bronze BS 1400AB2, Stainless steel Interface for water supply ANS1150# / DIN PN16 Interface for foam supply 1 x NPT M, 2x NPTM ANSI, DIN, etc. The specifications and information herein are subject to change...

Open the catalog to page 7
M-FOI Inductor general datasheet - 8

MATRE Foam Inductors Insertion rate 1% or 3% (Tolerance according to NFPA 11) Flow tolerance nominal value ±5% Minimum pressure loss 30% of inlet pressure The specifications and information herein are subject to change without notice.

Open the catalog to page 8
M-FOI Inductor general datasheet - 9

MATRE Foam Inductors 5 Capacities at rated k-values The specifications and information herein are subject to change without notice.

Open the catalog to page 9
M-FOI Inductor general datasheet - 10

MATRE Foam Inductors The specifications and information herein are subject to change without notice.

Open the catalog to page 10

All Matre Maskin AS catalogs and brochures

  1. M-SKD10

    2 Pages

  2. M-SKD11

    2 Pages

  3. M-SKD20

    2 Pages

  4. M-SKD21

    2 Pages

  5. M-BP15

    2 Pages

  6. M-BP30

    2 Pages

  7. M-BP40

    2 Pages

  8. M-BP60

    2 Pages

  9. M-BWP60

    1 Pages

  10. M-WP60

    1 Pages

  11. M-TRT2-03163

    2 Pages

  12. TET4

    2 Pages