CLM100

CLM100

CLM100

Product catalog summary
Overview: The Maretron CLM100 is a current loop monitor that converts 4-20mA current loop transducer data into digital data for display on Maretron devices. It supports a wide range of transducers for monitoring various parameters such as voltage, current, flow rate, temperature, and more.
Specifications:
  • Operating Voltage: 9 to 32 Volts DC
  • Power Consumption: 400mA maximum
  • Load Equivalence Number: 8
  • Reverse Battery and Load Dump Protection
  • Size: 3.50” x 4.20” x 2.03”
  • Weight: 13 oz. (368.5 g)
Environmental and Mechanical Standards:
  • Operating Temperature: -25°C to 55°C
  • Storage Temperature: -40°C to 70°C
  • Relative Humidity: 93%RH @40°C
  • Vibration and Solar Radiation: Compliant with IEC 60945
  • Degree of Protection: IP64
Certifications: The CLM100 complies with NMEA 2000® standards and is tested to IEC 60945 for maritime navigation and radiocommunication equipment.
Applications: The device is used for machinery monitoring, vibration monitoring of pumps and motors, shaft speed monitoring, and load monitoring on vessel components.
Accessories: Various pressure transducers and a pressure snubber are available for use with the CLM100.
Data Transmission: The CLM100 transmits data using NMEA 2000® PGNs, including fluid flow rate, DC voltage/current, humidity, pressure, and temperature.
See more

Catalog excerpts

CLM100-1

Current Loop Monitor Maretron’s CLM100 converts commercially available 4-20mA current loop transducers into digital data so a wide variety of information can be displayed on Maretron displays. Numerous 4-20mA current loop transducers are supported by the CLM100 including transducers for monitoring DC voltage and current, flow rate, distance, linear velocity and acceleration, angle, angular velocity and acceleration, temperature, humidity, resistance, strain gauges, force (load cell), pressure, decibels, and rotational rate. Some typical applications where the CLM100 is used together with a commercial available 4-20mA transducers include machinery monitoring using accelerometers and vibration sensors. Vibration monitoring of pumps, motors, fans, compressors, and gear boxes provides an early warning of potential problems resulting in fewer breakdowns and reduced maintenance expenses. Another application example using the CLM100 is shaft speed monitoring. A commercially available 4-20mA rotational rate transducer is coupled to the shaft of interest and the CLM100 converts the transducer data to an RPM that can be read on a compatible NMEA 2000® display. And if you’re concerned about the force exerted on a mast stay or perhaps a vessel tow attachment point, commercially available clevis pins with a 4-20mA interface can be connected to the CLM100 and the corresponding load monitored using any of Maretron’s display products. The following accessories are available for the CLM100: Used Together with Commercially Available 4-20mA Current Loop Transducers Converts Analog Transducer Data to Digital Data (NMEA 2000®) Digital Data Displayed on Maretron Displays PART NUMBER CLM100-01 Loop Monitor Current PT-0-3PSI-01 Pressure Transducer 0 to 3 PSI PT-0-5PSI-01 Pressure Transducer 0 to 5 PSI PT-0-10PSI-01 Pressure Transducer 0 to 10 PSI PT-0-50PSI-01 Pressure Transducer 0 to 50 PSI PT-0-100PSI-01 Pressure Transducer 0 to 100 PSI PT-0-300PSI-01 Pressure Transducer 0 to 300 PSI PT-0-500PSI-01 Pressure Transducer 0 to 500 PSI PT-0-1000PSI-01 Pressure Transducer 0 to 1000 PSI PT-0-3000PSI-01 Pressure Transducer 0 to 3000 PSI PT-0-5000PSI-01 Pressure Transducer 0 to 5000 PSI PT-SNUB-01 Snubber Pressure PT-V-0-1BAR-01 Pressure Transducer Vacuum to 1 Bar

 Open the catalog to page 1
CLM100-2

Transducer Interface Independently Programable DC Voltage, DC Current, Flow Rate, Distance, Linear Velocity, Linear Acceleration, Angle, Angular Velocity, Angular Acceleration, Temperature, Humidity, Resistance, Strain Gauge, Force (Load Cell), Pressure, Decibels, Rotational Rate Operating Modes Current Loop Excitation Voltage 3.45” (87.6mm) Over Full Transducer Range Maritime Navigation and Radiocommunication Equipment & Systems Maritime Navigation and Radiocommunication Equipment & Systems Electromagnetic Compatibility Default Rate Actual Pressure Temperature, Extended Range Generic Sensor...

 Open the catalog to page 2

All Maretron catalogs and brochures

  1. CLMD16

    2  Pages

  2. CLMD12

    2  Pages

  3. N2KBuilder

    1  Page

  4. N2K ANALYZER

    1  Page

  5. MBB200C

    2  Pages

  6. SMS100

    2  Pages

  7. DSM410

    2  Pages

  8. DSM250

    2  Pages

  9. Cloud Service

    2  Pages

  10. Maretron catalog

    126  Pages

  11. MBB300C

    2  Pages

  12. FPM100

    2  Pages

  13. SSC300

    2  Pages

  14. TSM800C

    2  Pages

  15. TSM1330C

    2  Pages

  16. N2KView

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.