Standards
The document outlines the international standards applicable to MarelliMotori marine motors, including the IEC 60034 series for performance, protection, cooling, construction, noise limits, and thermal protection, as well as IEC 60092 for electrical installation in ships.
Essential and Non-Essential Service
Equipment is classified into essential and non-essential services based on their importance for vessel propulsion and steering. Essential services include steering gears, fuel pumps, and fire-extinguishing pumps.
Classification Societies
MarelliMotori motors comply with standards from IACS members like ABS, BV, DNV, and others. Test requirements vary based on service classification and motor power.
Mountings and Positions
Motor mountings and positions are defined by IEC 60034-7 codes, with various configurations available for different frame sizes.
Materials
The motors are constructed from materials like aluminum and cast iron, with specific components made from steel and polyamide, depending on the motor type and size.
Balancing and Vibration Grades
Motors are balanced to IEC 60034-14 standards, with options for normal, reduced, or special vibration grades. Vibration speed values are provided for different shaft heights.
Noise
Noise levels are measured according to ISO R 1680, with average sound pressure levels provided in data tables.
Bearings and Lubrication Intervals
Bearings have a theoretical lifetime exceeding 50,000 hours, with lubrication intervals varying by motor speed and frame size. Regreasing systems are available for certain models.
Coupling
Motors are designed for elastic or flexible coupling to avoid axial or radial forces on the shaft.
Degree of Protection
Standard motors have an IP55 protection degree, with IP56 available on request, indicating resistance to dust and water ingress.
Terminal Boxes and Cable Entry
Terminal boxes are equipped with six leads and can be positioned on top or sides, depending on the motor type and size.
Grounding
Grounding terminals are provided inside and outside the terminal box.
Condensation Drainage
Motors can be equipped with drainage holes for environments with high humidity.
Protective Treatments
Motors are painted for corrosion resistance, with standard and special paint processes available. Internal surfaces are treated with insulating enamel.
Mechanical Tolerances
Tolerances for dimensions and shaft extensions are specified according to IEC 60072-1 standards.
Specifications
The document outlines the specifications for motors, including frame sizes, shaft heights, and electrical tolerances. Frame sizes are categorized as up to 132 J6 and greater than 132 H6, with shaft height tolerances specified as up to 250 mm with a tolerance of -0.5 mm, and greater than 250 mm with a tolerance of -1 mm.
Electrical Tolerances
Electrical tolerances comply with IEC 60034-1 standards. Key parameters include power factor, locked rotor current, efficiency, locked rotor torque, speed, and pull-out torque. Specific tolerances are provided for each parameter.
Voltage, Frequency, and Connections
Motors are designed for specific power supplies, with stator windings connected in star or delta configurations. The document specifies the maximum allowable Total Harmonic Distortion (THD) at 10%, with higher levels requiring derating.
Polarities and Connection Diagrams
Available polarities include 2, 4, 6, 8 poles for single speed and 4/8, 4/6 for double speed motors. Connection diagrams for single and double speed motors are provided.
Insulation and Temperature Rise Class
MarelliMotori motors use Class F insulation systems. The motors are rated for a temperature rise class F at a maximum ambient temperature of 45°C, with derating required for different conditions.
Outputs and Deratings
Output ratings are based on continuous duty S1, with derating factors provided for different ambient temperatures. Duty types S2 and S6 allow for increased permissible outputs using specified multiplying factors.
Consecutive Startings
The document provides guidelines for allowed starting times per hour, considering cold and warm motor conditions.
Thermal Protections
Standard magnetothermal circuit breakers are recommended for motor protection, with additional thermal protection options available.
Anticondensation Heaters
These heaters prevent water condensation by heating the motor when the supply is interrupted. Specifications for power values and availability are provided.
Efficiency and Power Factor
Efficiency and power factor values are given for rated outputs, with a table for estimating values at different loads.
Technical Data
Detailed technical data for aluminium motors, including performance at rated output for different pole configurations and starting conditions, is provided.
Technical Data Overview - Cast Iron Motors
Specifications
The document provides detailed technical specifications for cast iron motors operating at 380V and 50Hz across different pole configurations (2, 4, 6, and 8 poles). Key parameters include rated output (kW), speed (rpm), torque (Nm), current (A), efficiency (%), power factor (cos), starting current ratio (Is/In), starting torque ratio (Ts/Tn), breakdown torque ratio (Tmax/Tn), sound pressure level (LpA in dB(A)), moment of inertia (J in kgm2), and approximate weight (kg).
Performance at Rated Output
The motors are designed for Direct On Line (D.O.L.) starting. Performance metrics are provided for each motor type, indicating their efficiency and operational characteristics under rated conditions. The data includes variations in performance based on the number of poles, which affects speed and torque.
Key Observations
  • Efficiency generally increases with higher power outputs, reaching up to 96.8% for larger motors.
  • Sound pressure levels vary, with larger motors typically producing higher dB(A) levels.
  • Power factor values are consistently high, indicating efficient power usage.
  • Starting and breakdown torque ratios provide insights into the motor's capability to handle load variations.
Applications
The motors are suitable for various industrial applications, including fans and pumps, as indicated by the dual winding configurations for specific models.
Recommendations
Selection of motor type should consider the specific application requirements, focusing on efficiency, torque, and power factor to ensure optimal performance and energy savings.
See more

Catalog excerpts

Three Phase Squirrel Cage Induction Motors-1

Marine Motors Three Phase Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES 63 - 400 SIZES MarelliMotori ASI.CT.033.2

 Open the catalog to page 1
Three Phase Squirrel Cage Induction Motors-2

MarelliMotori is part of the FKI group of companies serving the world in the sectors of power generation, transmission and distribution. With over one hundred years of experience, MarelliMotori is a name synonymous with Quality and Manufacturing Excellence in the production of rotating machines. MarelliMotori is recognised as a leading supplier to the Industrial, Petrochemical and Marine sectors, offering a complete range of standard and custom solutions for low and medium voltage motors demanded by our customers. Our ability to offer flexible and rapid solutions is an integral part of achieving...

 Open the catalog to page 2
Three Phase Squirrel Cage Induction Motors-3

CONTENTS Page ESSENTIAL AND NON-ESSENTIAL SERVICE 5 BALANCING AND VIBRATION GRADES 7 BEARINGS AND LUBRICATION INTERVALS 8 BEARINGS OF MARINE MOTORS IN STANDARD CONFIGURATION 8 TERMINAL BOXES AND CABLE ENTRY 9 VOLTAGE, FREQUENCY AND CONNECTIONS 11 TEMPERATURE RISE AND AMBIENT TEMPERATURE 11 EFFICIENCY AND POWER FACTOR 14 TECHNICAL DATA - ALUMINIUM MOTORS 15 4/8 POLES - 4/6 POLES, FAN AND PUMP APPLICATIONS 17 4/8 POLES - 4/6 POLES, FAN AND PUMP APPLICATIONS 20 4/8 POLES - 4/6 POLES, FAN AND PUMP APPLICATIONS 23 4/8 POLES - 4/6 POLES, FAN AND PUMP APPLICATIONS 26 TECHNICAL DATA-CAST IRON MOTORS...

 Open the catalog to page 3
Three Phase Squirrel Cage Induction Motors-4

CONTENTS Page 4/8 POLES - 4/6 POLES, FAN AND PUMP APPLICATIONS 40 4/8 POLES - 4/6 POLES, FAN AND PUMP APPLICATIONS 44 DIMENSIONS - ALUMINIUM MOTORS 45 DIMENSIONS - CAST IRON MOTORS 49 Marelli Motori

 Open the catalog to page 4
Three Phase Squirrel Cage Induction Motors-5

International Standard Title IEC 60034 - 5 Classifications of degrees of protection (IP code) IEC 60034 - 6 Methods of cooling (IC code) IEC 60034 - 7 Classification of type of construction and mounting arrangement (IM code) IEC 60034 - 8 Terminal markings and direction of rotation IEC 60034 - 11 Built-in thermal protection IEC 60034 - 12 Starting performance of rotating electrical machines ESSENTIAL AND NON-ESSENTIAL SERVICE Onboard equipment is classified by Naval Registers considering the importance of its specific service. Two services are defined: The former identifies all those services...

 Open the catalog to page 5
Three Phase Squirrel Cage Induction Motors-6

Mountings and positions are defined by the following codes according to IEC 60034-7: B: Horizontal - V: Vertical Mounting code Mounting category Type of shaft extension Mounting arrangement Frame Size Frame Size 1. Motors with feet 2. Flanged Motor: unthreaded through holes 3. Flanged Motor: threaded dead holes !: Cast Iron Motors 63 frame without anti-rain canopy For other mountings refer to IEC 60034-7.

 Open the catalog to page 6
Three Phase Squirrel Cage Induction Motors-7

The components of MarelliMotori aluminium and cast iron series motors are made of the materials described in the following tables. N-end shield Aluminium Motors N-end shield Cast Iron Motors Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron Cast Iron BALANCING AND VIBRATION GRADES The motors are dynamically balanced with a half key applied to the shaft extension, in accordance with standard IEC 60034-14, to vibration severity grade normal (N) in standard configuration. The following table indicates the maximum rms vibration speed values (vrms) with respect to the various shaft...

 Open the catalog to page 7
Three Phase Squirrel Cage Induction Motors-8

BEARINGS AND LUBRICATION INTERVALS The theoretical lifetime of bearings, Lioh according to ISO 281/1 Standard, of horizontal construction motors in standard configuration, without external forces (radial and/or axial) is in excess of 50,000 hours. The lifetime of bearings is determined by multiple factors and specifically by: the lifetime of the grease, the environmental conditions, the external loads and vibrations. The cast iron and aluminium motors <132 frame size mount respectively double sealed and double screen deep-groove ball bearings greased for life. The corresponding grease life under...

 Open the catalog to page 8
Three Phase Squirrel Cage Induction Motors-9

MarelliMotori marine motors are mechanically designed to be coupled to the driven load with an elastic or flexible coupling, without any axial and/or radial force trasmitted to the motor shaft. For possible external axial and/or radial loads contact MarelliMotori. The motor protection against the penetration of dust and liquid is identified by a code: the degree of protection - IP55, where the first number in code means: 5 - Ingress of dust is not totally prevented but dust does not enter in sufficient quantity to interfere with satisfactory operation of the The second number in the code offered...

 Open the catalog to page 9
Three Phase Squirrel Cage Induction Motors-10

CONDENSATION DRAINAGE Motors installed outdoors or used for intermittent work in environments with high humidity levels can be provided with holes for condensation drainage. Motors from 100 to 400 frame size have water drainage holes as standard. In order to assure the correct positioning of the holes the mounting position of the motors must be specified. PROTECTIVE TREATMENTS EXTERNAL SURFACES Standard painting process is F96831 as described in the following table. The painting thickness ensures an optimum resistance against corrosive environments. A special painting according to F96819 specification...

 Open the catalog to page 10
Three Phase Squirrel Cage Induction Motors-11

VOLTAGE, FREQUENCY AND CONNECTIONS The electrical data tables given in the present catalogue refer to motors designed to operate under one of the following power supplies. Stator windings connection of single speed motors is specified in the following table. Double speed motors have two separate windings, both star connected. For different connections and or different supplies contact MarelliMotori. Maximum Total Harmonic Distortion (THD) level admitted on supplied voltages is 10%. Higher harmonic distortion levels cause an increase in the temperature rise of the motors. In those cases the power...

 Open the catalog to page 11
Three Phase Squirrel Cage Induction Motors-12

The output ratings listed in this catalogue refer to continuous duty S1, rated voltage and frequency, ambient temperature between -20°C and +45°C. In different environmental conditions the outputs ratings can be obtained by applying the derating factors given in Permissible outputs of motors operating in S2 or S6 duty-type can be increased by the following multiplying factors: Aluminium Motors Cast Iron Motors Short time duty type Frame size Short time duty type Aluminium Motors Continuous operation periodic type Frame size Cast Iron Motors Continuous operation periodic type Contact MarelliMotori...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.