1. Catalogs
  2. Marelli Motori
  3. Hydropower MJT series

Hydropower MJT series

Hydropower MJT series
1 / 18 PagesView full catalog

Hydropower MJT series

Product catalog summary
Overview: MarelliGenerators offers a variety of synchronous and asynchronous generators tailored for hydropower applications, emphasizing reliability, efficiency, and customizable designs to meet diverse technical standards and environmental conditions.
Specifications:
  • Nominal Output: Asynchronous generators range from 428 to 1500 kWA; synchronous generators range from 333 to 4000 kVA.
  • Voltage: Options include low (380-480 V) and medium (3000-6600 V) voltage.
  • Insulation: Class H for synchronous and Class F for asynchronous generators, featuring VPI system and tropicalization for corrosion protection.
Performance and Safety:
  • Reliability: Ensures long life with high safety factors and corrosion protection.
  • High Performance: Utilizes advanced technologies for enhanced efficiency.
  • Safety Features: Equipped with space heaters, temperature sensors, and optional electronic control devices for real-time monitoring.
Customization Options:
  • Customizable in voltage, pole number, shaft orientation, and protection degree (up to IP 55).
  • Additional features include flywheels, bushings, and various control devices.
Standards and Compliance: Conforms to IEC 60034-1, CEI EN 60034-1, BS 4999-5000, VDE 0530, NF 51-100, OVE M-10, and NEMA MG 1.22 standards, suitable for CE marked machinery.
Operating Conditions:
  • Compatible with parallel operation with other generators.
  • Rated outputs are based on installation height up to 1000 m asl and ambient temperature of 40°C.
  • Overloads allowed under specific conditions with necessary cooldown periods.
Technical Features:
  • Excitation System: Self-excited, brushless type, maintaining voltage within ±0.5% of nominal value.
  • Overloads: Allowed up to 50% for two minutes under specific conditions.
  • Protection: Standard IP 23, with options for higher protection levels using heat exchangers.
Mechanical Options: Include air filters, heat exchangers, sleeve bearings, shaft extensions, and sensor arrangements.
Electrical Options: Include power factor regulators, remote control rheostats, and digital AVR among others.
See more

Catalog excerpts

Hydropower MJT series-1

Three phase Synchronous and Asynchronous Generators HYDROPOWER APPLICATIONS

 Open the catalog to page 1
Hydropower MJT series-2

HYDROPOWER PLANT GENERATORS MarelliGenerators offers a wide range of solutions for hydropower applications. Our synchronous and asynchronous generators represent the best choice due to their certified quality, their versatile design allowing the generator to be customised to your needs, and to the experience acquired by more than 100 years of production. The undisputed quality proved by all MarelliGenerators products is shown by their high reliability, high efficiency and by their unchanged performance during many years of service. SYNCHRONOUS GENERATORS Power range @ 50 Hz - Low voltage ASYNCHRONOUS...

 Open the catalog to page 2
Hydropower MJT series-3

MarelliGenerators represents the best know-how within the hydropower field by ensuring our product has outstanding technical features. RELIABILITY • Long life endurance of electrical components and bearings. • Class H insulation system for synchronous and class F for asynchronous generators. Impregnation with polyester resin using the Vacuum Pressure Impregnation (VPI) system. A further protection from any corrosion phenomenon is guaranteed by a tropicalization treatment. • High safety factors to warrant the functionality of generators even in the worst working conditions. HIGH PERFORMANCE •...

 Open the catalog to page 3
Hydropower MJT series-4

FRAME SIZES 400 - 710 SYNCHRONOUS GENERATORS: TECHNICAL FEATURES STANDARDS All generators are designed according to the IEC 60034-1, CEI EN 60034-1, BS 4999-5000, VDE 0530, NF 51-100, OVE M-10 and NEMA MG 1.22 standards and can be incorporated in the “CE” marked machinery. AVAILABLE VOLTAGE Generators can be supplied with the following voltage range: • Low voltage (380 - 480 V) • Medium voltage (3.000 - 6.600 V) Voltages not listed can be supplied on request. EXCITATION SYSTEM Generators are self-excited through a brushless type excitation system. The voltage is maintained within ± 0,5% of the...

 Open the catalog to page 4
Hydropower MJT series-5

INSULATION Class H standard insulation system allows a maximum winding temperature rise of 125°C referring to an ambient temperature of 40°C. Windings are impregnated with polyester resin using the latest technology (VPI system). An enamel insulator (tropicalization treatment) coats all inner parts of the generator in order to protect it from corrosion. TEMPERATURE SENSORS Generators are equipped with three PT100 temperature sensors (one for each phase) installed into the slots to supervise the stator winding temperature and with a PT100 for each bearing to monitor its temperature (**). To control...

 Open the catalog to page 5
Hydropower MJT series-6

SYNCHRONOUS GENERATORS / LOW VOLTAGE kVA rating @ Temperature Rise / Ambient Temp. (°C) Type on request on request on request *: 690 V recommended **: Showed data could change depending on mounting. The rated outputs refer to the following conditions: balanced and non deforming load, altitude below 1.000 m asl, power factor from 0,8 to 1. For values of overspeed greater than as listed, please contact MarelliMotori.

 Open the catalog to page 6
Hydropower MJT series-7

SYNCHRONOUS GENERATORS / LOW VOLTAGE kVA rating @ Temperature Rise / Ambient Temp. (°C) Type on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request *: 690 V recommended **: Showed data could change depending on mounting. The rated outputs refer to the following conditions: balanced and non deforming load, altitude below 1.000 m asl, power factor from 0,8 to 1. For values of overspeed greater than as listed, please contact...

 Open the catalog to page 7
Hydropower MJT series-8

SYNCHRONOUS GENERATORS / MEDIUM VOLTAGE kVA rating @ Temperature Rise / Ambient Temp. (°C) 3000V Type on request on request on request on request on request on request on request on request **: Showed data could change depending on mounting. The rated outputs refer to the following conditions: balanced and non deforming load, altitude below 1.000 m asl, power factor from 0,8 to 1. For values of overspeed greater than as listed, please contact MarelliMotori.

 Open the catalog to page 8
Hydropower MJT series-9

SYNCHRONOUS GENERATORS / MEDIUM VOLTAGE kVA rating @ Temperature Rise / Ambient Temp. (°C) 3000V Type on request on request on request on request 6.000 6.700 8.100 9.000 9.600 on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request on request **: Showed data could change depending on mounting. The rated outputs refer to the following conditions: balanced and non deforming load, altitude below 1.000 m asl, power factor from 0,8 to 1. For values of overspeed greater...

 Open the catalog to page 9
Hydropower MJT series-10

SYNCHRONOUS GENERATORS / OVERALL DIMENSIONS [mm] Mounting: IM B3 - Air cooled (IC01)

 Open the catalog to page 10
Hydropower MJT series-11

SYNCHRONOUS GENERATORS / OVERALL DIMENSIONS [mm] Mounting: IM B3 - Air-to-water heat exchanger (IC81W) Dimensions for 450 frame size on demand Mounting: IM V10 - Air-to-water heat exchanger (IC81W) Dimensions for 450 frame size on demand ®

 Open the catalog to page 11
Hydropower MJT series-12

FRAME SIZES 250 - 630 ASYNCHRONOUS GENERATORS: TECHNICAL FEATURES STANDARDS All generators are designed according to the IEC 60034-1 and CEI EN 60034-1 standards and can be incorporated in the “CE” marked machinery. AVAILABLE VOLTAGE Generators can be supplied with nominal voltages from 380 V up to 690 V. Voltages not listed can be supplied on request. ENVIRONMENTAL CONDITIONS Rated outputs refer to an installation height up to 1.000 m asl and to a maximum ambient temperature of 40°C. For higher altitudes and different temperature values the rated outputs must be recalculated using the factors...

 Open the catalog to page 12
Hydropower MJT series-13

EQUIPMENT Standard • Class F insulation • VPI impregnation type • Windings protected against corrosion (tropicalization) • Six-leads stator winding into the terminal box • N° 3 PTC into the stator winding • IP 23 index of protection • IP 55 index of protection for the terminal box • Bearings: more than 100.000 h life time Electric options Class H insulation type N° 3 PT100 into the stator winding N° 1 PT100 on each bearing Anti-condensation heaters In-terminal-box measurement transformers Encoder Tachometric dynamo Mechanical options Inlet and outlet air filters (IP 44) Air-to-fresh water heat...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.