Power Gas Brochure
24Pages

{{requestButtons}}

Catalog excerpts

Power Gas Brochure - 1

Power Generation Power Gas Engines for Power Generation

Open the catalog to page 1
Power Gas Brochure - 2

Contents Gas Engines for Power Generation Application Type and Product Range . . . . . . . . . . . . . . . . . . . . . . . . 3 Customized Service Reliability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Customer Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Open the catalog to page 2
Power Gas Brochure - 3

Gas Engines for Power Generation Efficient Electricity and Heat Generation Manufacturers and operators of CHP applications have strong requirements. Robust, compact engines have to work reliably 24 hours a day 7 days per week. Economic operation over the life cycle of the entire plant is therefore essential. This requires a high level of efficiency by maximum utilisation of primary energy and low plant operating costs. With their continous development programme, MAN engines always make a contribution to greater efficiency. Reliable and low in emissions. Application Type and Product Range...

Open the catalog to page 3
Power Gas Brochure - 4

■ Cylinders and arrangement: 4 cylinders in-line ■ Mode of operation: four-stroke spark-ignition gas engine ■ Engine cooling: water-cooled ■ Exhaust system: water-cooled exhaust pipe ■ Air-fuel mixture cooling: four-stroke spark-ignition gas engine turbo charger with pressure-oil lubricated bearings and water-cooled bearing pedestal two-stage cooler water-cooled exhau

Open the catalog to page 4
Power Gas Brochure - 5

Technical Data Technical features E0834 Mode of operation at engine speed Engine version Exhaust heat based on 120 °C 1) Air-fuel ratio Emissions status NOX 2) mg/Nm 3 1) at 100 % load 2) with 5 % exhaust-gas oxygen 3) m = lean, st = stoichiometric 5) in accordance with German Industrial Standard DIN ISO 3046, Part 1 4) Data conditional and on request Technical data is based on a calorific fuel value of 10 kWh/Nm 3 for natural gas and 6 kWh/Nm 3 for special gas. The values are provided for information purposes only and are non-binding. Dimensions E0834 Type designation A-Overall length...

Open the catalog to page 5
Power Gas Brochure - 6

Description of Engines Characteristics E0836 E nnCylinders nnMode Characteristics E0836 LE nnCylinders nnMode 6 cylinders in-line four-stroke spark-ignition gas engine water-cooled water-cooled exhaust pipe 6 cylinders in-line four-stroke spark-ignition gas engine turbo charger with pressure-oil lubricated bearings and mixture cooling: two-stage cooler water-cooled bearing pedestal

Open the catalog to page 6
Power Gas Brochure - 7

Technical Data Technical features E0836 Mode of operation at engine speed Engine version Exhaust heat based on 120 °C 1) Air-fuel ratio Emissions status NOX 2) mg/Nm 3 1) at 100 % load 2) with 5 % exhaust-gas oxygen 4) in accordance with German Industrial Standard DIN ISO 3046, Part 1 3) m = lean, st = stoichiometric 5) Data conditional and on request Technical data is based on a calorific fuel value of 10 kWh/Nm 3 for natural gas and 6 kWh/Nm 3 for special gas. The values are provided for information purposes only and are non-binding. Dimensions E0836 Type designation A-Overall length...

Open the catalog to page 7
Power Gas Brochure - 8

Technical features E0836 Mode of operation at engine speed Engine version Exhaust heat based on 120 °C 1) Air-fuel ratio 1) at 100 % load 2) with 5 % exhaust-gas oxygen 4) in accordance with German Industrial Standard DIN ISO 3046, Part 1 3) m = lean, st = stoichiometric 5) Data conditional and on request Technical data is based on a calorific fuel value of 10 kWh/Nm 3 for natural gas and 6 kWh/Nm 3 for special gas. The values are provided for information purposes only and are non-binding. Dimensions E0836 Type designation A-Overall length B-Overall width C-Overall height All data are...

Open the catalog to page 8
Power Gas Brochure - 9

Description of Engines Characteristics E2876 E nnCylinders nnMode Characteristics E2876 TE and LE nnCylinders nnMode 6 cylinders in-line four-stroke spark-ignition gas engine water-cooled water-cooled exhaust pipe 6 cylinders in-line four-stroke spark-ignition gas engine turbo charger with water-cooled turbine housing and ­ pressure-oil lubricated bearings mixture cooling: two-stage cooler in the case of LE 302/202/212 9

Open the catalog to page 9
Power Gas Brochure - 10

Technical Data Technical features E2876 Mode of operation Engine version Displacement ISO standard power 5) Air-fuel ratio Coolant Exhaust heat based on 120 °C 1) Efficiency 1) 1) at 100 % load 2) with 5 % exhaust-gas oxygen 5) in accordance with German Industrial Standard DIN ISO 3046, Part 1 3) m = lean, st = stoichiometric 4) Data conditional and on request 6) technical data is based on 5 kWh/Nm 3 Technical data is based on a calorific fuel value of 10 kWh/Nm 3 for natural gas and 6 kWh/Nm 3 for special gas. The values are provided for information purposes only and are non-binding....

Open the catalog to page 10
Power Gas Brochure - 11

Technical features E2876 Mode of operation Engine version Displacement ISO standard power 5) Air-fuel ratio Coolant Exhaust heat based on 120 °C 1) Efficiency 1) 1) at 100 % load 2) with 5 % exhaust-gas oxygen 5) in accordance with German Industrial Standard DIN ISO 3046, Part 1 3) m = lean, st = stoichiometric 4) Data conditional and on request 6) technical data is based on 5 kWh/Nm 3 Technical data is based on a calorific fuel value of 10 kWh/Nm 3 for natural gas and 6 kWh/Nm 3 for special gas. The values are provided for information purposes only and are non-binding. Dimensions E2876...

Open the catalog to page 11
Power Gas Brochure - 12

Description of Engines Characteristics E2676 E nnCylinders nnMode Characteristics E2676 LE nnCylinders nnMode 6 cylinders in-line four-stroke spark-ignition gas engine water-cooled water-cooled exhaust pipes 6 cylinders in-line four-stroke spark-ignition gas engine turbo charger with water-cooled turbine housing and ­ pressure-oil lubricated bearings cooling: mixture cooling: two-stage cooler

Open the catalog to page 12
Power Gas Brochure - 13

Technical Data Engine version Air-fuel ratio Exhaust heat 1) at 100% load 2) with 5% exhaust-gas oxygen 3) m = 5) in accordance with German Industrial Standard DIN ISO 3046, Part 1 4) Data conditional and on request Technical data is based on a calorific fuel value of 10 kWh/Nm3 for natural gas and 6 kWh/Nm3 for special gas. The values are provided for information purposes only and are non-binding. All data are reference values. Please request installation drawings for detailed specifications.

Open the catalog to page 13

All MAN Engines catalogs and brochures

  1. ON-ROAD

    76 Pages

  2. OFF-ROAD

    20 Pages

Archived catalogs