Waste Water Treatment System
12Pages

{{requestButtons}}

Catalog excerpts

Waste Water Treatment System - 1

WASTEWATER TREATMENT Technical description - Waste water treatment Hydronetik-System Ludwig Elkuch AG | LI-9487 Bendern | www.elkuch.com office@elkuch.com | T +423 375 84 00 | F +423 375 84 01

Open the catalog to page 1
Waste Water Treatment System - 2

Elkuch Waste Solutions – WASTEWATER TREATMENT Ludwig Elkuch AG | LI-9487 Bendern | www.elkuch.com office@elkuch.com | T +423 375 84 00 | F +423 375 84 01

Open the catalog to page 2
Waste Water Treatment System - 3

Elkuch Waste Solutions – WASTEWATER TREATMENT 1. Introduction In recent years, there has been a growing global desire to restore the environment and protect it from the harmful effects of all forms of pollution. Particularly in the wastewater treatment market, an increasing industrialisation is leading to stricter standards for the disposal of wastewater and to a change in technology standards. Today, both municipalities and the industry must treat their wastewater in such a way that they comply with limit values set by the national environmental protection authorities when discharging it...

Open the catalog to page 3
Waste Water Treatment System - 4

Elkuch Waste Solutions – WASTEWATER TREATMENT The advantages of the Elkuch Waste Solutions wastewater treatment system are:        Compact design, low space requirement Easy transport (modular components) Saving of disposal costs Relief of the staff (no daily observation necessary) Hygienic and clean solution Maintenance-friendly Design of the main components in stainless steel 2. Principle and functional description In the following, the function of the Hydronetik-system is explained in more detail and the procedure is explained. Overflow into main tank Inspection opening High...

Open the catalog to page 4
Waste Water Treatment System - 5

Elkuch Waste Solutions - WASTEWATER TREATMENT Suction nozzle-Station Hopper - Station Docking - Station Waste Pipe iter Treatment Vacuunrf pump Water Treatment 1. The greasy wastewater is fed via the main supply line to the main tank of the system. Due to the difference in density and gravity, heavy particles sink to the bottom of the tank and settle there as sludge. Light materials such as oils rise to the water surface and form a layer of grease. Separation phase ^ ^ ^ Sludge 2. If the water level in the main tank rises due to a constant water inflow, the flotation process starts when the...

Open the catalog to page 5
Waste Water Treatment System - 6

Elkuch Waste Solutions - WASTEWATER TREATMENT 4. Flotation is stopped when the standby level is reached. Subsequently, any dirty water still in the high separation container is drained off into the main tank so that it can be treated during the next cycle. At the same time, various cleaning valves are opened to clean the various system components and prevent dirt from sticking. 5. When the cleaning process is finished, the system is ready again and waits for the start level to be reached again. 6. Usually after 4 weeks the fat and sludge containing main tank can be disposed by a disposal...

Open the catalog to page 6
Waste Water Treatment System - 7

Elkuch Waste Solutions - WASTEWATER TREATMENT 4. Example: Design for a canteen with 1000 meals/day Project data At peak times, up to a maximum of 1000 meals are prepared daily in a canteen. The kitchen waste water must be pre-treated before being discharged into the public sewerage system. The treatment of the kitchen waste water with the Hydronetik-system was specially developed to minimise the water level inside the main tank. This considerably reduces the disposal costs for the customer. The closed system prevents the formation of odours. The treatment process depends primarily on the...

Open the catalog to page 7
Waste Water Treatment System - 8

Elkuch Waste Solutions - WASTEWATER TREATMENT In this example the 2nd method is selected and Q is calculated based on the operating mode. Q = (V x F) : (t x 3600) Qs = maximum waste water income [l/s] V = average daily volume of waste water kitchen operations: V = M x Vm M = Number of hot food portions produced daily F = Shock load factor depending on the operating type t = Average daily operating time in hours Vm = Operation type specific water quantities per meal portion For the operatione type canteen the following parameters have resulted: The determination of the nominal size results...

Open the catalog to page 8
Waste Water Treatment System - 9

Elkuch Waste Solutions – WASTEWATER TREATMENT Our recommended system size based on NS 5.9 Based on the nominal size calculation and the installation room data, the following system size is now suggested:  LEB188930 – 4000 litres Ø1900 Ludwig Elkuch AG | LI-9487 Bendern | www.elkuch.com office@elkuch.com | T +423 375 84 00 | F +423 375 8

Open the catalog to page 9
Waste Water Treatment System - 10

Elkuch Waste Solutions - WASTEWATER TREATMENT Technical data Lipoo 4.0 Ludwig Elkuch AG | LI-9487 Bendern | www.elkuch.com office@elkuch.com | T +423 375 84 00 | F +423 375 84 01

Open the catalog to page 10
Waste Water Treatment System - 11

Elkuch Waste Solutions - WASTEWATER TREATMENT • What is the recommended capacity/layout of a system? The design of our waste water treatment system is calculated based on the water input from the kitchen (l/s) (chapter 4). • What size of system room do I need? For usual grease separators + treatments you need about 10-30 m2. Due to our "All-In-One" system we only need about 5-15 m2, depending on the size of the plant. • What tank sizes are available? Ludwig Elkuch AG | LI-9487 Bendern | www.elkuch.com office@elkuch.com | T +423 375 84 00 | F +423 375 84 01

Open the catalog to page 11
Waste Water Treatment System - 12

Elkuch Waste Solutions – WASTEWATER TREATMENT Does the system spread odours or pollutants? No, it's a closed system. The exhaust air from the our system is routed to the roof.  How often must I dispose of the Hydronetik - system? It depends on the amount of waste water produced. Usually the disposal intervals are about 1x per month.  Are there laws/regulations for the operation of our wastewater treatment system? In Germany/Switzerland/Austria, an individual approval application is submitted for each of our systems. Our wastewater treatment plant is not regulated by the standards for...

Open the catalog to page 12