Super Spool III Installation Instructions
13Pages

{{requestButtons}}

Catalog excerpts

Super Spool III Installation Instructions - 1

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions LINDGREN-PITMAN, INC. 2615 N.E. 5th Avenue * Pompano Beach, Florida 33064 * U.S.A. (954)943-4243 * (954)943-7877 Fax E-mail: longline@gate.net http://www.lindgren-pitman.com

Open the catalog to page 1
Super Spool III Installation Instructions - 2

Installation instructions for Lindgren-Pitman Super Spool III LOCATION A location must be selected that assures crew safety and efficient hauling and setting of the line. If assistance in choosing a mounting location is required consult the factory or your local dealer for assistance. The foot print dimensions for LP super Spool III can be found in Appendix A or obtained from the factory. Sufficient distance should be maintained between the spool level winder and the pulley or roller preceding the level winder to reduce level winder stress and maintenance. Please note that a distance equal...

Open the catalog to page 2
Super Spool III Installation Instructions - 3

ACCESSORIES Lindgren-Pitman Line Setters LS-3, LS-4, LS-5 Lindgren-Pitman line setters are designed to be compatible with Lindgren-Pitman long line reels in series hydraulic circuits so no additional pump is required. The output of the long line reel control valve can be connected directly to the input of the line setter. Fish Hoist or other Fish hoist or other accessory may be included in the same hydraulic circuit. The control valve for any accessory must be installed in the circuit between the pump and the spool control valve so that it can not create additional backpressure on the spool...

Open the catalog to page 3
Super Spool III Installation Instructions - 4

Appendix B HYDRAULIC SPECIFICATIONS AND ADJUSTMENTS FOR SERIES III SYSTEMS Series III line setters and long line spools have an improved hydraulic system that will operate more smoothly, more efficiently and with fewer adjustments than previous hydraulic systems. Many hydraulic systems will not need any adjusting after installation. Hydraulic system piping should be designed to minimize backpressure losses to 250 psi if possible. For most systems 3/4 inch pipe or hose will suffice unless flows are higher than 12 GPM or lines are extremely long. Pressure drops for many sizes are shown in the...

Open the catalog to page 4
Super Spool III Installation Instructions - 5

40" Diameter Reel Spool Control Valve & Manifold Ready for 33C Control Cable Braking Relief RPGT-LWN 48 INCH DIAMETER LONG LINE REELS Backpressure 200 psi 300 psi 400 psi 500 psi 600 psi The counterbalance (A207 10Q C04) can be set accurately by preventing the spool rotation and then actuating the control valve in the hauling direction and adjusting counterclockwise to increase or clockwise to decrease the pressure. Read pressure at gage port GL or tee into port ML. Line setter power relief (RVGB - LCN) can be adjusted by threading the line setter and tying the input line to a fixed point....

Open the catalog to page 5
Super Spool III Installation Instructions - 6

TROUBLE SHOOTING Spool will not brake to follow line setter slow down. Counterbalance too low – adjust counterclockwise. Spool wil not brake properly while hauling. * Check motor work port connections. Manifold "ML" to motor "L" Manifold "MR" to motor "R" * Manifold control valve relief is set too low. Increase relief valve setting. Line setter will not pull line to desired speed from spool Counterbalance too high - adjust clockwise or line setter power too low - adjust clockwise. Check pump output. Need more hauling power Turn counterbalance ccw, but do not exceed backpressure +1400 psi...

Open the catalog to page 6
Super Spool III Installation Instructions - 7

PRESSURE LINE BEfOflE VALVE OPTION PluOT - SPEED CONTROL

Open the catalog to page 7
Super Spool III Installation Instructions - 8

40" Diameter Reels CASE DRAIN TO TANK KYB Motor / Manifold Connections DRAIN TO TANK CONNECT TO MOTOR “R” WORK PORT CONNECT TO MOTOR “L” WORK PORT OUTPUT TO LINE SETTER (RETURN TO TANK THROUGH FILTER IF NO LINE SETTER) FROM HYDRAULIC PUMP 10 – 15 GPM 1500 PSI

Open the catalog to page 8
Super Spool III Installation Instructions - 9

CASE DRAIN TO TANK Poclain Motor / Manifold Connections CONNECT TO ML ON MANIFOLD OUTPUT TO LINE SETTER (RETURN TO TANK THROUGH FILTER IF NO LINE SETTER) CONNECT TO MOTOR “R” WORK PORT CONNECT TO MOTOR “L” WORK PORT FROM HYDRAULIC PUMP 10 – 15 GPM 1500 PSI

Open the catalog to page 9
Super Spool III Installation Instructions - 10

ML PORT - CONNECTS TO REAR PORT OF RINEER MOTOR MR PORT - CONNECTS TO FRONT PORT OF RINEER MOTOR WATER INLET / OUTLET LINDGREN-PITMAN Super Spool III Longline Spool Hydraulic Power Unit ELECTRICAL INSTRUCTIONS ENCLOSED PRESSURE PORT TO LINE SETTER WATER INLET / OUTLET RETURN PORT FROM LINE SETTER

Open the catalog to page 10
Super Spool III Installation Instructions - 11

Main Spool Motor Hydraulic Power Unit Case Drain Return to hydraulic reservoir LINDGREN-PITMAN Super Spool III Longline Spool Hydraulic Circuit Connections Manifold Detail

Open the catalog to page 11
Super Spool III Installation Instructions - 12

LINDGREN-PITMAN TWIN SUPER SPOOL III Hydraulic Schematic

Open the catalog to page 12
Super Spool III Installation Instructions - 13

Main Spool Motors Hydraulic Power Unit Case Drain Return to hydraulic reservoir LINDGREN-PITMAN Twin Super Spool III Longline Spool Hydraulic Circuit Connections Manifold Detail

Open the catalog to page 13