28x Installation Instructions
11Pages

{{requestButtons}}

Catalog excerpts

28x Installation Instructions - 1

LINDGREN-PITMAN, INC. 2615 N.E. 5th Avenue * Pompano Beach, Florida 33064 * U.S.A. (954)943-4243 * (954)943-7877 Fax E-mail: longline@gate.net http://www.lindgren-pitman.com

Open the catalog to page 1
28x Installation Instructions - 2

Installation Instructions for Lindgren-Pitman Super Spool III LOCATION A location must be selected that assures crew safety and efficient hauling and setting of the line. If assistance in choosing a mounting location is required consult the factory or your local dealer for assistance. The foot print dimensions for LP super Spool III can be found in Appendix A or obtained from the factory. Sufficient distance should be maintained between the spool level winder and the pulley or roller preceding the level winder to...

Open the catalog to page 2
28x Installation Instructions - 3

ACCESSORIES Fish Hoist or other Fish hoist or other accessory may be included in the same hydraulic circuit. The control valve for any accessory must be installed in the circuit between the pump and the spool control valve so that it can not create additional backpressure on the spool control circuit. START UP All connections should be checked for correctness and tightness prior to operating the pump. Operate the pump for several minutes before operating the control valves. Use this time to inspect closely for any leaks. During this time the system will purge...

Open the catalog to page 3
28x Installation Instructions - 4

Appendix B HYDRAULIC SPECIFICATIONS AND ADJUSTMENTS FOR SERIES III SYSTEMS Hydraulic system piping should be designed to minimize backpressure losses to 250 psi if possible. For most systems 1/2 inch pipe or hose will suffice unless flows are higher than 12 GPM or lines are extremely long. Pressure drops for many sizes are shown in the appendix....

Open the catalog to page 4
28x Installation Instructions - 5

LINDGREN-PITMAN Super Spool III Longline Spool Hydraulic Power Unit ELECTRICAL INSTRUCTIONS ENCLOSED

Open the catalog to page 5
28x Installation Instructions - 7

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LINDGREN-PITMAN, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LINDGREN-PITMAN, INC. IS PROHIBITED. NEXT ASSY Optional Hauling Relief Standard Stopping Relief Standard Hauling Relief INTERPRET GEOMETRIC TOLERANCING PER: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL STOPPING PRESSURE RELIEF PORT A CW UNLESS OTHERWISE SPECIFIED: HAULING PRESSURE RELIEF 410010-(5) - 2030 psi Standard Stopping Relief 410010-(31) - 1200 psi (Optional Hauling...

Open the catalog to page 7
28x Installation Instructions - 8

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LINDGREN-PITMAN, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LINDGREN-PITMAN, INC. IS PROHIBITED. NEXT ASSY INTERPRET GEOMETRIC TOLERANCING PER: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL UNLESS OTHERWISE SPECIFIED:

Open the catalog to page 8
28x Installation Instructions - 9

PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LINDGREN-PITMAN, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LINDGREN-PITMAN, INC. IS PROHIBITED. INTERPRET GEOMETRIC TOLERANCING PER: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL UNLESS OTHERWISE SPECIFIED:

Open the catalog to page 9
28x Installation Instructions - 10

LINDGREN-PITMAN, INC. 28x- 2 Speed Motor Case Drain Must Be Installed For 2 Speed Operation Lever Position For High Torque Low Speed Cross-Over Relief Valve * NOTE - MOTOR WILL NOT OPERATE IN THE LOW TORQUE/ HIGH SPEED SETTING IN THE REVERSE DIRECTION. F:\WORK\Hydraulic Power Units\Cart & Manifolds\2SpeedMotor.cdr Lever Position For Low Torque High Speed

Open the catalog to page 10
28x Installation Instructions - 11

INTERPRET GEOMETRIC TOLERANCING PER: DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL ANGULAR: MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL UNLESS OTHERWISE SPECIFIED: PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LINDGREN-PITMAN, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LINDGREN-PITMAN, INC. IS PROHIBITED.

Open the catalog to page 11

All Lindgren-Pitman catalogs and brochures

Archived catalogs