Catalog excerpts
p r o d u c t d ata s h e e t ACTUATOR LA12/LA12 PLC Features: • 12/24 V DC permanent magnetic motor • Max. thrust 750 N • Reinforced glass fibre piston rod • Compact design • Protection class: IPX1 • Colour: black • Straight cable’s without plug • Back fixture available in 2 different variants: 01 or 02 (factory mounted) • Built-in limit switches (not adjustable) • High-strength plastic housing protects motor and gear Options: • Reed-switch • Potentiometer (max. 100 mm stroke length) • Hall-sensor for (PLC-option) • Long life absolute feedback (HALL - Potentiometer) • Easy to use interface – with integrated power electronics for direct PLC connection • Stainless steel inner tube and piston rod eye • Back fixtures in aluminum or stainless steel • Protection class: IP66 for the types 12xx00-xxxxxxxx • Protection class: IP66 for outdoor use (dynamic), furthermore the actuator can be washed down by a high pressure cleaner (IP69K – static) for the types 12xx/02/03-xxxxxxxx Usage: • Duty cycle up to 20 % or max. 12 min./hour at 0 - 20°C ambient temperature • Ambient temperatures: -20° to + 40°C • Typical noise level dB (A) 55-57, measuring method DS/EN ISO 3746, actuator not loaded Thanks to the small size and outstanding performance, the LA12 actuator provides a practical and cost-effective alternative to traditional pneumatic systems and gear motors. ® The LA12 is a member of the TECHLINE Family it is characterized by its robust design allowing the actuator to be used in harsh conditions. The LA12 is designed to meet the challenge, based on the philosophy that it must be able to operate under extreme conditions. The actuator is ideal for mobile “off-highway” equipment such as agricultural, forestry and construction machines. iFLEX is a descriptive term under which every TECHLINE® actuator with built-in intelligence is unified. For more information on iFLEX, please see: www.linak.com/techline
Open the catalog to page 1Technical specifications: New Type Old Type Spindle Pitch (mm) Thrust max. Push/Pull (N) Self-lock max. (Push) (N) Self-lock max. (Pull) (N) Typical speed 0/full load (mm/s) 12XX00-1XXX12XX 12.1 2 750 750 375 14 12XX00-1XXX24XX 12.1 2 750 750 375 12XX00-2XXX12XX 12.2 4 300 300 150 12XX00-2XXX24XX 12.2 4 300 300 12XX00-3XXX12XA 12.3 6 200 200 12XX00-3XXX24XA 12.3 6 200 200 Stroke length (in steps of 30 mm) Typical Amp. at full load (A) 24V - 12V 5 40 - 130 - 4.6 14 6 40 - 130 2.2 - 27 16 40 - 130 - 2.5 150 27 16 40 - 130 1.5 - 100 40 28 40 - 130 - 2.2 100 40 28 40 - 130 1.0 - Self locking...
Open the catalog to page 2Ordering example: 1 = Black straight 2.3 m Jack With reed 2 = 3 core stereo jack black straight 2.3 m 3 = 3 core black straight 0.75 m 4 = 4 core black straight 0.75 m With analog feedback (Potentiometer) 24 = 24VDC Motor (only option for PLC) 100 = Standard stroke length Material 00 = Plastic inner tube 02 = Stainless steel inner tube and Stainless steel eye (AISI 303)/0301118 w. bushes 03 = Stainless steel inner tube and Stainless steel eye (AISI 304)/0301244 w. bushes Memory positioning Necessary cable type A = Potentiometer 0-10 volt/max 100 mm stroke 8 for PLC (8 Core) B = Analog...
Open the catalog to page 3Dimensions: 36.3 170.7 19.6 +0.2 0 20.5 6.1 22 10.1 245 01 LA12 Stainless steel 255mm 16.5 16 02 10.1+0.2 6.1+0.2 25.9 0 -0.2 21.9+0.2 Piston rod eye: 11 17 Beware of the direction of travel when ordering LA12 with Jack Plug. STANDARD ST ND R A AD Direction of travel D irection of travel REVERSED R V R ofD E E SEtravel Direction D irection of travel +0.1 0 85 +0.1 0 31.9 10.1 50 6.1+0.2
Open the catalog to page 4LA12 curves speed and current: The above values are average values and made with a stable power supply and an ambient temperature of 20° C. Actuator connections Basic Actuator without positioning Actuator with Relative positioning Actuator with absolute positioning Actuator with Relative positioning Actuator with absolute positioning Actuator with built in H bridge
Open the catalog to page 5Environmental test – Climatic: Test Specification Comment Degrees of protection EN60529 – IP6x IP6X - Dust: Dust-tight, No ingress of dust. Actuator is not activated. EN60529 – IPx6 IPX6 – Water: Ingress of water in quantities causing harmful effects is not allowed. Duration: 100 litres pr. minute in 3 minutes Actuator is not activated. EN60529 – IPx6dynamic IPX6 –Connected actuator: Actuator is driving out and in for 3 min. 100 (l/min) jet of water is placed at the wiper ring for 3 (min). DIN40050 – IP69K High pressure cleaner: Water temperature: +80°C Water pressure: 80 bar Spray angle:...
Open the catalog to page 6Environmental test – Electrical, it does not apply for the PLC option Test Specification Comment Radiated emission 10 m distance CISPR 22 79 dBμ V (QP), 0.15 - 0.5 MHz 66 dBμ V (AV), 0.15 - 0.5 MHz 73 dBμ V (QP), 0.5 - 30 MHz 60 dBμ V (AV), 0.5 - 30 MHz Radiated emission 10 m distance CISPR 22 30 dBμ V/m, 30 - 230 MHz 37 dBμ V/m, 230 - 1000 MHz Specification for radio disturbance and immunity EN 55016-1-2 Electromagnetic fields EN 61000-4-3 12 V/m, 80% AM, 1kHz 80 - 1000 Mhz 3 V/m, 80% AM, 1 kHz 1.4 - 2.0 GHz 1 V/m, 80% AM 2.0 - 2.7 GHz. ESD IEC 61000-4-2 ± 6 kV contact discharge ± 8 kV air...
Open the catalog to page 7Complying standards, it does not apply for the PLC option Specification Focus on 2004/104/EC Automotive EMC Directive 2004/104/EC on electrical and electronic car components VEHICLES AND MOBILITY EN 12184 Electrically powered wheelchairs, scooters and their chargers. Requirements and test methods EN/IEC 60204-1 Safety of machinery – Electrical equipment of machines – Part 1: General requirements INDUSTRIAL AUTOMATION EN/IEC 60204-32 Safety of machinery – Electrical equipment of machines – Part 32: Requirements for hoisting machines • INDUSTRIAL AUTOMATION • PLATFORMS AND LIFTS EN/IEC...
Open the catalog to page 8All Linak catalogs and brochures
-
Control Box CO71
13 Pages
-
Foot Switch FS3
8 Pages
-
Actuator LA40
16 Pages
-
DESKLINE®
12 Pages
-
Quality Matters
8 Pages
-
Built-in DB5
4 Pages
-
Built-in DB6
8 Pages
-
Built-in actuator DB14
4 Pages
-
External charger CHJ2
4 Pages
-
Better Solutions - Better Care
28 Pages
-
Bluetooth® Adapter
4 Pages
-
Battery pack BAJ
6 Pages
-
Li-Ion battery disclaimer
2 Pages
-
Focus on Marine
24 Pages
-
TECHLINE Overview
20 Pages
-
LA36
40 Pages
-
LA31
8 Pages
-
LA25
40 Pages
-
LA23
8 Pages
-
LA12
17 Pages
Archived catalogs
-
ACTUATOR LA28 COMPACT
8 Pages
-
ACTUATOR LA28
8 Pages
-
ACTUATOR LA22
4 Pages
-
ACTUATOR LA14
24 Pages
-
Lifting Column DL4
4 Pages
-
Dual Actuator TD1 280 SMPS
4 Pages
-
Lifting Column BL1
4 Pages
-
linear actuator la35 MODBUS
2 Pages
-
linear actuator LA35
8 Pages
-
Linear Actuator LA29
4 Pages
-
Linear Actuator LA23
4 Pages