Overview: The LA36 actuator by LINAK is a durable and powerful actuator designed for extreme conditions, offering a maintenance-free alternative to hydraulic solutions. It features an integrated controller and is available in 12, 24, or 36 V DC motor options.
Specifications: The actuator provides thrust from 500 N to 10,000 N, with a maximum speed of 160 mm/sec depending on load and spindle pitch. Stroke lengths range from 100 to 999 mm. It includes built-in endstop switches and a non-rotating piston rod eye. The protection class is IP66 (dynamic) and IP69K (static).
Options: The LA36 offers mechanical overload protection, exchangeable cables, special anodised housing, and IECEx/ATEX certification for Zone 21. It supports communication protocols like Modbus, LIN bus, and CAN bus, and provides analogue or digital feedback for precise positioning.
Usage and Performance: The duty cycle varies with stroke length and load, with a maximum of 20% at 600mm stroke and 5% at 10,000N. The operating temperature ranges from -30°C to +65°C, with full performance between +5°C and +40°C.
Technical Details: The actuator includes a permanent magnet motor, integrated brake, and mechanical slip clutch for overload protection. The housing is made of cast aluminium, suitable for harsh environments, and the spindle part is constructed from anodised aluminium and stainless steel.
Environmental Tests: The LA36 has undergone climatic, mechanical, and electrical environmental tests to ensure reliability under various conditions.
Recommendations: Users are advised to follow specific instructions to prevent damage, such as ensuring the motor is shorted when stopped for maximum self-locking ability and selecting a power supply that can handle backward load dumps.
Procedures and Recommendations: Regular activation of limit switches is recommended to ensure precise positioning. The actuator may enter a position lost state, maintaining the highest feedback level until re-initialized. Both physical end stop switches need activation for correct feedback initialization.
Norms and Standards: The document mentions compatibility with the SAE J1939 standard for CAN bus configurations, including specific wiring and speed requirements.
Feedback Configurations: Various feedback configurations are available, including PWM, Single Hall, Analogue Feedback Voltage (AFV), and Analogue Feedback Current (AFC). Each has its pros and cons, such as suitability for long-distance transmission or immunity to electrical noise.
Actuator Configurations: Customizable options include current limits, speed settings, and virtual end stops. The document provides guidance on recommended ranges and conditions affecting these settings, such as temperature changes.
Soft Start and Stop Specifications: Soft stop duration ranges from 0.01 to 0.29 seconds due to back-EMF from the motor. The soft start duration is 0.3 seconds for both directions, with a range from 0 to 30 seconds. It is advised not to use 0 seconds for soft start to avoid stress on the actuator due to higher inrush current.
System Combination Possibilities: Includes LA36 IC, RF receiver, HB40 DP, and signal cable.
Environmental Tests - Climatic: Includes cold, dry heat, temperature change, damp heat, and salt mist tests to ensure durability under various conditions.
Degrees of Protection: IP66 and IP69K ratings ensure dust-tight and water ingress protection under specified conditions.
Mechanical Tests: Includes free fall, vibration, bump, and shock tests to ensure mechanical robustness.
Electrical Tests: Includes power supply, HF-immunity and emission, and automotive transients tests to ensure electrical reliability.
Ex Certification: Allows actuator use in Ex dust areas with specific temperature and dust protection ratings.
Terms of Use: Users must determine the suitability of LINAK products for specific applications. LINAK products are subject to modifications without prior notice, and availability cannot be guaranteed. All sales are subject to LINAK's Standard Terms of Sale and Delivery.
See more

Catalog excerpts

LA36-1

LINAKSJ LINAK.COM/TECHLINE WE IMPROVE YOUR LIFE

 Open the catalog to page 1
LA36-2

LA36 The actuator LA36 is one of the most solid and powerful LINAK actuators, designed to operate under extreme conditions. The LA36 is a maintenance-free product with a long lifetime and a high IP degree. This high-quality actuator offers a very strong alternative to hydraulic solutions. TEGRATED CONTROLLER This TECHLINE® actuator comes with IC - Integrated controller. For more information on our IC options, please see: www.linak.com/techline Features: • 12, 24 or 36 V DC Permanent magnetic motor (IC only 12/24 V DC) • Thrust from 500 N - 10,000 N depending on gear ratio and spindle pitch •...

 Open the catalog to page 2
LA36-4

Permanent magnet motor 12, 24, or 36V DC* Motor: 2 x 14 AWG PVC cable Control: 6 x 20 AWG PVC cable ** Gear ratio: 6 different gear ratios available in steel (500 N, 1,700/2,600 N, 4,500 N, and 6,800/10,000 N) Slip clutch: Mechanical overload protection through an integrated slip clutch Integrated brake ensures a high self-locking ability. The brake is deactivated when the actuator is powered in order to obtain a high efficiency Hand crank: As a standard feature the actuator can be operated manually The housing is made of casted aluminium, coated for outdoor use and in harsh conditions Spindle...

 Open the catalog to page 4
LA36-5

Technical specifications * The typical values can have a variation of ± 20% on the current values and ± 10% on the speed values. Measurements are made with an actuator in connection with a stable power supply and an ambient temperature at 20°C. ** There are limitations on the stroke length if you need full load, please see " LA36 Load v. Stroke Length" *** Fully loaded actuators need a soft start in order to prevent the clutch from slipping when starting (see speed and current curves). Self locking ability To ensure maximum self-locking ability, please be sure that the motor is shorted when stopped....

 Open the catalog to page 5
LA36-6

LA36 Load versus stroke length N.B. LA36 500 - 1.700 N is with 20 mm LA36 500 - 6.800 N is with 12 mm LA36 500 - 10.000 N is with 8 mm spindle pitch spindle pitch spindle pitch For applications that only operate in pull the limitations are 999 mm stroke and 10,000 N load. Safety factor 2. Stroke and built-in tolerances

 Open the catalog to page 6
LA36-7

When STROKE <300 = Built-in dimension: 200+STROKE LENGTH When STROKE >300 = Built-in dimension: 250+STROKE LENGTH _ Keep a clearance when mounting a bracket 1 When mounting a custom bracket on the moving part of the actuator, please observe the minimum clearance between bracket and cylinder top, when fully retracted, to avoid jamming and destruction of actuator drive train. A SEE DETAIL SEEDETAIL A A DETAIL SEE DETAIL AA Cable conduits for an LA36 IECEx/ATEX actuator must be ordered separately, if needed. C To order a cable conduits kit, please choose one of the following item numbers: Item number...

 Open the catalog to page 7
LA36-8

Built-in dimensions Piston rod Back fixture Back fixture

 Open the catalog to page 8
LA36-9

LA36 Piston Rod Eyes When ordering AISI (304 and up) piston rod eye and back fixture, stainless steel screws are automatically included. Option “0” AISI 303 Option “1” Free cutting steel galvanised surface Option “2” Free cutting steel galvanised surface Option “5” Free cutting steel galvanised

 Open the catalog to page 9
LA36-10

LA36 Piston Rod Eyes Option “A” AISI 304 Option “C” 10KN = Max. load 6800 N in pull AISI 304 The Piston Rod Eye is only allowed to turn 0 - 90 degrees.

 Open the catalog to page 10
LA36-11

Option “1” and “2” Free cutting steel galvanised surface Option “3” and “4” Free cutting steel galvanised surface

 Open the catalog to page 11
LA36-12

Option “7” and “8” Free cutting steel galvanised surface

 Open the catalog to page 12
LA36-13

LA36 Back fixture orientation

 Open the catalog to page 13
LA36-14

Manual hand crank The manual hand crank can be used in the case of power failure. The cover over the Allen Key socket must be unscrewed before the Allen Key can be inserted and the Hand Crank operated. Hand Crank Torque: 6-8 Nm Hand Crank rpm: Max. 65 Piston Rod movement per turn The power supply has to be disconnected during manual operation. If the actuator is operated as a Hand crank, it must only be operated by hand, otherwise there is a potential risk of overloading and hereby damaging the actuator. Cable dimensions Y-cable dimensions: Brown: Blue: Violet: Black: Red: Brown: Blue: Violet:...

 Open the catalog to page 14
LA36-15

Cable dimensions Power cable dimensions: Ø 2.0mm AWG*:14mm Ø 2.0mm AWG :14mm *AWG: American Wire Gauge Signal cable dimensions: Violet: Black: Red: Yellow: Green: White: Violet: Black: Red: Yellow: Green: White:

 Open the catalog to page 15
LA36-16

Speed and current curves - 12V motor The values below are typical values and made with a stable power supply and an ambient temperature of 20°C. All measurements above describe the spindle pitch (e.g. 20mm) and the gear type (e.g. E gear) of the actuator. Speed and current are based on a nominal power supply of 12, 24, 36VDC. When ordering LA36F When purchasing the LA36 actuator with fast gear and slide for the end-stop function, the customer has been informed that there is an increased risk that the activation arm for end-stop can be damaged during use, especially if the actuator runs to limit...

 Open the catalog to page 16
LA36-17

Speed and current curves - 24V motor The values below are typical values and made with a stable power supply and an ambient temperature of 20°C. LA36 24V motor speed vs. load All measurements above describe the spindle pitch (e.g. 20mm) and the gear type (e.g. E gear) of the actuator. Speed and current are based on a nominal power supply of 12, 24, 36VDC. When ordering LA36F When purchasing the LA36 actuator with fast gear and slide for the end-stop function, the customer has been informed that there is an increased risk that the activation arm for end-stop can be damaged during use, especially...

 Open the catalog to page 17
LA36-18

Speed and current curves - 36V motor The values below are typical values and made with a stable power supply and an ambient temperature of 20°C. LA36 36V motor speed vs. load All measurements above describe the spindle pitch (e.g. 20mm) and the gear type (e.g. E gear) of the actuator. When ordering LA36F When purchasing the LA36 actuator with fast gear and slide for the end-stop function, the customer has been informed that there is an increased risk that the activation arm for end-stop can be damaged during use, especially if the actuator runs to limit switch without load, both in the inner...

 Open the catalog to page 18

All Linak catalogs and brochures

  1. Actuator LA40

    16  Pages

  2. DESKLINE®

    12  Pages

  3. Built-in DB5

    4  Pages

  4. Built-in DB6

    8  Pages

  5. Focus on Marine

    24  Pages

  6. LA31

    8  Pages

  7. LA25

    40  Pages

  8. LA23

    8  Pages

  9. LA12

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.