Catalog excerpts
MEDLINE’ CARELINE’ UNAKSS LINAK.COM/MEDLINE-CARELINE WE IMPROVE YOUR LIFE
Open the catalog to page 1The LA40 is a low noise and powerful actuator which is available in a 1500N, 4000N, 6000N and an 8000N version. With the LA40, LINAK offers a new durable actuator with high speed/high performance and mechanical endstop for first failure safety making it the right choice for the future market. The LA40 versions are rated up to IPX6 Washable DURATM, except for the LA40 PL version which is rated up to IPX6. The LA40 8000 N is available in three versions: - Standard - High Performance (HP) - Patient Lift (PL) Based on the extensive knowledge and experience from previous actuator families, LINAK...
Open the catalog to page 2• Minimum built-in dimensions: Standard and High Performance version: Stroke + 170 mm With mechanical spline, stroke + 180 mm With QR, stroke + 180 mm With mechanical spline and QR, stroke + 190 mm With ratchet-spline and QR, stroke + 180 mm Patient Lift version: Stroke + 274 mm; S < 300 mm Stroke + 294 mm; S < 400 mm • Positioning options: Dual Hall with power switches & dual hall analogue, encoded with signal switches (16 pulses per rev.) Potentiometer input 0-5 Volt • Quick release: Standard version: Internal • Manual lowering: Only for Patient Lift version • Noise level: < 50 dB (A) •...
Open the catalog to page 3Actuator type: Spindle pitch: Only available for 8000 N version Standard Available for 4000 N without QR, 6000 N and all 8000 N HP/PL versions Only available for 4000 N version Only available for 1500 N version Stroke length: Safety: Feedback: Platform: Motor type: Endstop: IP degree: Colour: Back fixture: Back fixture rotation: From 50-405 m From 50-300 m From 50-200 m From 50-250 m n steps of 5 m n steps of 5 m n steps of 5 m n steps of 5 m n steps of 5 m 0A = Safety Nut 0D = Mech. Spline + Safety nut 0K = Ratchet Spline + Safety Nut 0L = Ratchet Spline + Safety Nut Only available for...
Open the catalog to page 4Dimension drawing LA40 Standard Drawing no.: 0404006 LA40 High Performance
Open the catalog to page 5Drawing no.: 0404017 LA40 Patient Lift
Open the catalog to page 6Details on back fixture: Back fixture (for further details see ordering example) End 1 X Back fixture overview - shown in standard rotation, also available in 90o turned C\J c::i c::i c::i Back fixture Back fixture end 1 end 2 End 1 + fixture end 1 6 Back Back fixture � � � ..- Back fixture Back fixture endfixture end 3 Back 2 End 2 + 7 Back fixture c::i c::i Back fixture End 4 d1 Back fixture end 2 Back Back fixture end End 3 fixture end 3 fixture endBack fixture end 4 fixture end 4 2 Back 3 Back ..c::i c::i Back fixture end 3 Back fixture end 4 C\J C\J
Open the catalog to page 7Details on piston rod eyes: Piston rod eyes for LA40 Standard: End 1 (Type D) With slot, no bushings End 2 (Type C) Solid, no bushings End 3 (Type D + option B) End 4 (Type C + option B) With slot, with bushings Solid, with bushings
Open the catalog to page 8Details on piston rod eyes: End 5 (Type F) Manual lowering Piston rod eyes for LA40 HP and PL: End 5 (Type E) Manual lowering End 6 (Type D) With slot, no bushings End 7 (Type D) With slot, with bushings
Open the catalog to page 9LA40 with mounting brackets – examples LA40 mounted with CA30-CA40:
Open the catalog to page 10Note: Mounting bracket must be ordered together with LA40 HP. It is not possible to install the mounting bracket afterwards.
Open the catalog to page 11LA40 - control box combination overview Drawing number Minimum build-in dimension Bracket article number Load curves: LA40 Standard, HP and PL: Load Chart
Open the catalog to page 12Speed and current graphs: (please note measurements are typical values) LA40 standard, motor type B: * With stable power supply
Open the catalog to page 13Speed and current graphs: (please note measurements are typical values) Extending LA40 8000N Actuator - Motortype G (4mm pitch) 33VDC Typical Current Typical Speed LA40 PL Extending LA40 PL 8000N Actuator - Motortype F (4mm pitch) 24VDC Typical Current Typical Speed * With stable power supply
Open the catalog to page 14LA40 standard, motor type G: Typical Current Typical Speed Typical Current Typical Current Typical Speed Typical Current Typical Speed Typical Speed Typical Current Typical Speed Typical Current Typical Speed
Open the catalog to page 15Copyright © LINAK 2019.03 MA M9-02-568-O . Chapter 5.22 Terms of use The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing accurate and up-to-date information on its products. However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same...
Open the catalog to page 16All Linak catalogs and brochures
-
Control Box CO71
13 Pages
-
Foot Switch FS3
8 Pages
-
DESKLINE®
12 Pages
-
Quality Matters
8 Pages
-
Built-in DB5
4 Pages
-
Built-in DB6
8 Pages
-
Built-in actuator DB14
4 Pages
-
External charger CHJ2
4 Pages
-
Better Solutions - Better Care
28 Pages
-
Bluetooth® Adapter
4 Pages
-
Battery pack BAJ
6 Pages
-
Li-Ion battery disclaimer
2 Pages
-
Focus on Marine
24 Pages
-
TECHLINE Overview
20 Pages
-
LA36
40 Pages
-
LA31
8 Pages
-
LA25
40 Pages
-
LA23
8 Pages
-
LA12
17 Pages
Archived catalogs
-
ACTUATOR LA28 COMPACT
8 Pages
-
ACTUATOR LA28
8 Pages
-
ACTUATOR LA22
4 Pages
-
ACTUATOR LA14
24 Pages
-
Lifting Column DL4
4 Pages
-
Dual Actuator TD1 280 SMPS
4 Pages
-
Lifting Column BL1
4 Pages
-
linear actuator la35 MODBUS
2 Pages
-
linear actuator LA35
8 Pages
-
Linear Actuator LA29
4 Pages
-
Linear Actuator LA23
4 Pages
-
Linear Actuator LA12
8 Pages