ACTUATOR LA22 Features: • 12/24 V DC permanent magnet motor • Max. thrust 400 N (300 N in 12V) • Stainless steel piston rod and piston rod eye made of reinforced plastic. • Duty cycle: Max. 10% or 2 min. in use followed by 18 min. not in use. • Ambient temperature +5° to +40° C • Compact construction/design • Protection class: IP51 • Colour: black • 1.0 m straight cable without plug (no cable with IP51) • Speed max. 37 mm/s • Extremely quiet operation • Max. stroke length 200 mm • Storage temperature: - 40° to + 70° C Options: • Protection class: IP65 (only back fixture D and E) Usage: • Should LA22 be used with a non Linak control unit, please ask the nearest Linak representative for further details. LA22 is an in-line actuator specially designed with a small overall dimension for easy use in industrial, agricultural and rehabilitation products. Thanks to its small outer dimensions and linear design, LA22 is well suited for applications where installation space is limited, such as on wheelchairs.
Open the catalog to page 1Technical specifications: Type Thrust Self-lock Typical speed max. (mm/s) max. Pull 0/full load* Pull Duty cycle (%) Typical amp. at full load (A) 12V * The speed values for both the 12V and 24V motor are the same. • LINAK control boxes are designed so that they will short-circuit the motor terminals (poles) of the actuator(s), when the actuator(s) are not running. This solution give the actuator(s) a higher self-locking ability. If the actuator(s) are not connected to a LINAK control box, the terminals of the motor must be short-circuited to give a higher selflocking ability. • The above figures...
Open the catalog to page 2LA22 24V motor speed v's load LA22 12V motor - Speed v's Load LA22 24V motor Current v's Load LA22 12V motor Current v's Load
Open the catalog to page 3Ordering example: XX XX XX XX (No cable when IP51) Cable: 0 = black straight 1.0 m IP-version: Motor type: Stroke length: Spindle pitch: 000 Back fixture type: Actuator type Accessories • CS16: electric limit switch, trips out the current to the actuator in the end position • Possibility of connecting a handset to the CS16 • LS/LSD: limit switch, to be mounted on the actuator THE CURRENT SUPPLY TO LINEAR ACTUATORS MUST BE CUT OFF IN CASE OF OVERLOAD AND WHEN THE ACTUATORS REACH END POSITION. Terms of use The user is responsible for determining the suitability of LINAK products for specific application....
Open the catalog to page 413 Pages
8 Pages
16 Pages
12 Pages
8 Pages
4 Pages
8 Pages
4 Pages
4 Pages
28 Pages
4 Pages
6 Pages
2 Pages
24 Pages
20 Pages
40 Pages
8 Pages
40 Pages
8 Pages
17 Pages
24 Pages
4 Pages
8 Pages
2 Pages
4 Pages
4 Pages
4 Pages
8 Pages
8 Pages
4 Pages
8 Pages