Overview: The Metricircuit™ Series 60,000 Signal Conditioner is designed for centralized signal conditioning of up to 60 channels, suitable for integration with DCS or other monitoring systems. It provides two proportional outputs per channel for level or temperature measurements, with field-adjustable calibrations.
Features:
  • Centralized signal conditioning for up to 60 channels.
  • Economical inputs into DCS or other monitoring systems.
  • Two proportional outputs per channel: 4-20mA and 0-1mA.
  • Field adjustable calibrations via DIP switches.
  • Standard line voltage of 115 VAC or 220 VAC.
Design and Installation: The Metricircuit is built using printed circuit boards, each handling up to 10 channels. It supports any combination of level or temperature sensors and can be mounted in a steel NEMA 12 enclosure for wall mounting. The system can be placed up to 1000 feet from sensor locations, with intrinsic safety barriers available for certain applications.
Specifications:
  • Sensor Inputs: 10 channels per board, connected via terminal blocks.
  • Enclosure Capacity: Supports 1, 2, 4, or 6 boards.
  • Input Signals: Resistance range from 630Ω to 31,000Ω, with adjustable span and resistance levels.
  • Primary Output: 4-20mA signal with a maximum load impedance of 600Ω.
  • Secondary Output: 0-1mA signal with a maximum load impedance of 10,000Ω.
  • Power: Operates on 115/230 VAC ± 15%, with a frequency range of 45-400 Hz and a maximum power consumption of 25 watts.
Disclaimer: The information provided is not a specification and is offered in good faith. JOWA USA, Inc. does not assume liability for the use of the information or product, and users are responsible for determining suitability for their specific applications.
See more

Catalog excerpts

Metricircuit 60,000 Multi-tank-1

JOWA USA Metricircuit™ Series 60,000 Signal Conditioner Features: • Centralized signal conditioning for up to 60 channels • Economical inputs into DCS or other monitoring system • Two proportional outputs per channel - level or temperature • Field adjustable calibrations Description: The Metricircuit Series 60,000 is a multichannel signal conditioner for use with resistance-tape level and level/temp sensors gauging liquid and slurries. It is intended for central locations where multiple sensor signals can be brought together for signal processing. This central location facilitates calibration and routine system checks providing increased economy and efficiency. For each level or temperature sensor, resistance inputs are converted to two process outputs, 4-20mA and 0-1mA, which are fully adjustable in the field via DIP switches. All connections are by terminal blocks. Standard line voltage of 115 VAC or 220 VAC is acceptable. The Metricircuit is designed using printed circuit boards which will handle up to 10 channels each. Any combination of level or temperatures is acceptable. Up to six boards can be mounted in an enclosure. See the back of this data sheet for mounting dimensions. The Metricircuit 60,000 is designed for wall mounting and is housed in a steel NEMA 12 enclosure. It can be placed up to 1000 feet from resistance-tape sensor locations. For applications requiring level or level/temp sensors to be intrinsically safe, an approved intrinsic safety barrier is used.

 Open the catalog to page 1
Metricircuit 60,000 Multi-tank-2

Metricircuit™ Series 60,000 Signal Conditioner Specifications: General: Sensor inputs (channels): 10 per board. Connection: Terminal block. Enclosure capacity: 1, 2, 4 or 6 boards. Enclosure type: NEMA 12 (indoor mounting). Input Signals: Resistance range: 630Ω to 31,000Ω. Maximum resistance adjustment: 14 levels (DIP switches). Span adjust range: 30% to 200% of max. resistance. Span adjust: 16 levels (DIP switches). Primary Output: Signal type: 4-20mA, common return. Maximum load impedance: 600Ω. Maximum compliance voltage: 12 VDC. Format: Innage: 4mA at bottom (DIP switch selectable). Ullage:...

 Open the catalog to page 2

All JOWA USA catalogs and brochures

  1. ODME 2005

    2  Pages

  2. DeckMaster IV

    2  Pages

  3. Metrimeter

    2  Pages

  4. Sentry IV

    2  Pages

  5. Vanguard IV

    2  Pages

  6. PT90

    2  Pages

  7. PT40

    2  Pages

  8. MetriGuard

    2  Pages

  9. LA_HN_LA_HP

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.