UV STERILISER

UV STERILISER

UV STERILISER

Product catalog summary
Overview
The UV Steriliser is designed with low-pressure UV lamps powered by electronic high-frequency ballasts, ensuring high efficiency and low power consumption. The sterilization process is controlled by a microprocessor using data from a UV sensor. An intelligent lamp monitoring system alerts users to any lamp failures and their locations. An hour meter indicates when lamp replacement is necessary. All relevant data is displayed on a control cabinet screen.
Technical Specifications
  • Voltage: 110/230 VAC 50/60 Hz
  • Power Consumption: 35-290W depending on size
  • UV Dosage: 36000 Ws/cm²
  • Alarm: Open/closed 1A resistive relay output
  • Working Pressure: Max 10 bar
  • Material Chamber: Stainless Steel 316L
  • Weight: 15-25 kg depending on size
Main Features
  • Individual lamp monitoring system
  • LCD display
  • Standard UV sensor
  • Low power consumption
  • Compact design in stainless steel 316L
  • Equipped with a solenoid valve
Flow Capacity
The maximum flow capacity varies with water quality, with typical capacities ranging from T50=90% to T50=60%. The flow rates for different UV unit sizes are provided in a detailed table.
Company Information
Jowa Group is a trusted supplier of environmental protection equipment for the shipping industry, offering services for installation, operation, monitoring, and control. They have offices in Sweden, Norway, Germany, the Netherlands, the USA, Singapore, and China, with contact details provided for each location.
See more

Catalog excerpts

UV STERILISER-1

It is equipped with low pressure UV-lamps, powered by electronic high frequency ballasts, for highest efficiency and lowest power consumption. The sterilization process is microprocessor-controlled via data from the UV- sensor. The intelligent lamp monitoring system will, in case of any lamp failure, inform the user of this occurrence as well as the location of the broken lamp. The hour meter tells the user to change lamps when the limit of its using time is All necessary data is available in a display window on the control cabinet. website: www.jowa.se e-mail: ¡[email protected] e-mail: [email protected] JOWA GERMANY GMBH website: www.jowa.de e-mail: ¡[email protected] JOWA HOLLAND e-mail: [email protected] website: www.jowa-consilium.com e-mail: [email protected] 26, Lorong G Telok Kurau e-mail: [email protected] JOWA (Shanghai) Marine Equipment Co.,Ltd. 5111 Luo Shan Road, Pudong New Area e-mail: [email protected]

 Open the catalog to page 1
UV STERILISER-2

Flow capacity Maximum flow at different water qualities (m3/h). Normally the Max/Min capacity of a UV-unit is chosen between Maximum flow at different water qualities, [m3/h] Normally the Max/Min capacity of a UV-unitis chosen between T50=90% down to T50 = 60% Technical data Main Features » Individual lamp monitoring system » UV-sensor standard » Compact design in stainless steel 316L » Always with solenoid valve

 Open the catalog to page 2

All JOWA AB catalogs and brochures

  1. WWS

    2  Pages

  2. STP 2010

    2  Pages

  3. HYDROPHORE

    2  Pages

  4. FWU

    2  Pages

  5. DOSING UNITS

    2  Pages

  6. AG S

    2  Pages

  7. TANK MESURING

    8  Pages

  8. WDM

    2  Pages

  9. CWN

    2  Pages

  10. PES

    2  Pages

  11. FUEL SYSTEM

    2  Pages

  12. EBU

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.