Overview: This document serves as an instruction manual for flexible impeller pumps, specifically models F2P10-19, F3B-19, F3B-19 Oil Change, F38B-19, and F4B-19, all operating on 12/24 V DC. It includes original instructions and translations in multiple languages, with a focus on English for this summary.
Specifications: The pumps are self-priming and flange-mounted to a DC motor, suitable for applications such as bilge pumping, diesel fuel transfer, washdown, firefighting, and freshwater pumping. The F3B-19 Oil Change model is designed for oil changes in boats, with a switch to reverse flow direction.
Technical Description: The pump housing is made of PTMT thermoplastic polyester or brass, with components like wear plates and impellers made from AISI 316 stainless steel and NBR rubber, respectively. The motor is a 0.12 kW DC motor with built-in thermal protection, spark-protected according to ISO 8846 standards.
Installation and Operation: Pumps can be mounted in any position without loss of efficiency, but vertical installations should face downward. The motor should be close to the power source for full voltage. Specific installation instructions are provided for the F3B-19 Oil Change model, emphasizing proximity to the engine and the use of reinforced oil hoses.
Performance Data: Detailed performance data for each pump model is provided, including flow rates, power consumption, and recommended fuses for both continuous and intermittent operation.
Electrical Installation: The manual includes wiring diagrams and emphasizes compliance with ISO 10133 standards for low-voltage DC installations. It advises using spark-protected fuses and sealing cable connections with marine sealant.
Maintenance and Service: Regular maintenance includes replacing the impeller annually and using Johnson original impeller lubricant. Detailed disassembly and assembly instructions are provided for each pump model.
Warnings and Safety: The manual warns against dry running, pumping flammable liquids, and operating in temperatures exceeding 60°C. It also advises on the use of vacuum breakers to prevent damage from dry running.
Environmental Considerations: Disposal and recycling should comply with local regulations, and the product should be dismantled and sorted into material fractions where applicable.
Technical Specifications: The document describes self-priming, flexible impeller pumps designed for various applications such as bilge pumping, fresh water pumping, deck washing, fuel oil transfer, and fire pumping. The pumps are flange mounted to DC motors operating at 12/24 V. Key materials include PTMT thermoplastic polyester and brass for the body, AISI 316 stainless steel for wear plates, and NBR (nitrile) rubber for impellers and seals. The pumps can handle liquid temperatures up to +80°C and are equipped with motors that have built-in thermal protection and are ignition protected according to ISO 8846 standards.
Pressure and Capacity Data: Detailed pressure and capacity data for different pump models (F2P10-19, F3B-19, F38B-19, F4B-19) under continuous and intermittent duty conditions is provided. It includes amp draw, pressure (bar and kPa), flow rate (l/min and USGPM), and fuse requirements for both 12V and 24V operations.
Installation and Maintenance: Pumps can be mounted in any position, but vertical mounting with the pump head down is recommended. The motor should be close to the power source to ensure full voltage. Specific installation instructions are provided for the F3B-19 Oil Change pump, emphasizing the importance of short hose lengths and proper positioning to prevent accidental oil discharge. Maintenance instructions include disassembly and assembly steps, lubrication recommendations, and warnings against dry running and handling hazardous fluids.
Wiring and Electrical Installation: The document outlines wiring dimensions based on a 3% voltage drop and provides a wiring table for different pump models. It emphasizes the importance of using ignition-protected fuses and proper wire sealing with marine sealant. The pumps must be installed according to ISO 10133 standards for extra low voltage DC installations.
Operational Guidelines: The pumps are self-priming up to 3-4 meters, depending on the model, and require air-tight intake lines. Continuous duty is permissible up to 0.6 bar, with a maximum ambient temperature of +60°C. The document warns against dry running and provides guidelines for handling freezing weather and waste disposal.
Service Instructions: Detailed service instructions for disassembly and assembly of various pump models are provided, including lubrication and replacement of critical components like the impeller and O-ring. The document stresses the importance of using original Johnson Pump parts and lubricants for maintenance.
Accessories: Accessories such as vacuum switches and deck wash kits are mentioned, with specific functions and installation guidelines to enhance pump operation and prevent damage.
See more

Catalog excerpts

FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-1

Flexible Impeller Pumps F 2 P 10 - 19 12 / 2 4 V D C , F 3 B - 19 12 / 2 4 V D C , F 3 B - 19 O i l C h a n g e 12 / 2 4 V D C , F 3 8 B - 19 12 / 2 4 V D C , F 4 B - 19 12 / 2 4 V D C

 Open the catalog to page 1
FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-2

SE: Besök www.spxflow.com för mer information om vår världsomspännande organisation, våra godkännanden, certifieringar och lokala representanter. SPX FLOW, Inc. förbehåller sig rätten att ändra design och material utan föregående avisering. Designelement, konstruktionsmaterial och dimensioner som beskrivs i denna bulletin gäller endast som information och skall alltid bekräftas skriftligt för att vara gällande. EN: For more information about our worldwide locations, approvals, certifications, and local representatives, please visit www.spxflow.com. SPX FLOW, Inc. reserves the right to incorporate...

 Open the catalog to page 2
FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-3

Självsugande, flexibel impellerpump, flänsmonterad till likströmsmotor 12/24 V Typiska användningsområden Länspump, transport av dieselbränsle, spolpump, brandpump, färskvattenpump etc. F3B-19 Oil Change: Fast installerad pump nära båtens motor för byte av motorolja. Byt flödesriktning med hjälp av den fast monterade brytaren på motorn. Teknisk beskrivning F2P10 Pumphus: PTMT, Termoplastisk polyester Mässing Slitbrickor: AISI 316, rostfritt stål Impeller: NBR (nitril) gummi Tätning: Läpptätning, NBR (nitril) gummi O-ring: NBR (nitril) gummi Anslutning: ½” slang R½” eller ½”-14 NPTF eller 1” hose...

 Open the catalog to page 3
FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-4

Tryck- och kapacitetsdata (baserad på vatten vid 20°C och full spänning till motorn, 12.0 / 24.0 V om inget annat anges) F2P10-19 Kontinuerlig drift Rekomenderad säkring Rekomenderad säkring Rekomenderad säkring Varm olja ger högre flöde och lägre strömförbrukning Rekomenderad säkring Installation och skötsel Installation Generellt: Pumpen kan monteras i vilket läge som helst utan effektförlust. Emellertid rekommenderas att pumpen vänds nedåt när den monteras vertikalt. Montera motorn så nära kraftkällan som möjligt för att motorn ska få full spänning. Pumpen ska installeras så att den skyddas...

 Open the catalog to page 4
FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-5

åt motsatt håll/riktning för att fylla på olja. Kontrollera med motorns oljesticka för att få rätt oljenivå i motorn. Så snart motorn tömts på olja eller, vid påfyllning, då oljan i behållaren är slut, måste pumpen stängas av omedelbart genom att föra brytaren till mittläget. Annars finns risk för torrkörning. Kabelarea (baserat på 3% spänningsfall) Kabelarea * Kabellängden är det totala avståndet från batteriet till pumpen och tillbaka till batteriet. Använd gärna ett relä för att korta av de strömförande ledarna. Säkring Strömbrytare Svart Pump Pump Grön/gul Elektrisk installation F2P10-19...

 Open the catalog to page 5
FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-6

Pumpen ska installeras i enlighet med ISO 10133 (Båtar - Elektriska system Klenspänningsinstallationer för likström). Obs! Säkringen ska vara av gnistskyddad typ. Motorn har ett termiskt överbelastningskydd som skyddar motorn från överhettning. Skyddet återställs automatiskt då motorn svalnat. Om pumpen ansluts med separat jordningskabel ska denna vara gul/grön och anslutas till motorns fot. Se kopplingsschema på sid 5 för rätt installation. Negativ ledare ska vara svart. Välj kabeldimension efter total kabellängd enligt tabell på sid 5. Kabelanslutningarna ska tätas av med ett marint tätningsmedel...

 Open the catalog to page 6
FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-7

Vid installation som länspump Max uppfordringshöjd på trycksidan är 6 m. Pumpen ska placeras så att den inte kan sköljas över av slagvatten. Pumpen ska förses med en inloppssil eller ett filter som hindrar skräp från att komma in i pumpen. Minusgrader Vid frysrisk, dränera pumpen genom att lossa locket på pumpen. Glykol kan användas som frostskyddsmedel, men använd inte andra petroleumprodukter. Avfallshantering/Materialåtervinning Vid avfallshantering ska produkten lämnas för destruktion/återvinning enligt gällande lagstiftning. Vid tillämpliga fall demonteras och sorteras produkten i ingående...

 Open the catalog to page 7
FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-8

Montering 1. Fukta nya tätningen i såpvatten (5 % såpa), montera med läppen riktad mot impellersidan. 2. Smörj motoraxeln med vaselin eller liknande. Montera pumphuset till motorn. Smörj pumphusets impellerutrymme och lockets yta mot impellern med Johnson impeller lubricant 09-47086, glycerin tvål eller liknande. Montera impellern med en roterande rörelse i pumpens rotationsriktning. Smörj O-ringen med med Johnson impeller lubricant 09-47086, glycerin tvål eller liknande och placera den i läge och skruva fast locket. Impeller Impellern är en viktig säkerhetsdetalj i pumpen och bör bytas varje...

 Open the catalog to page 8
FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-9

Self-priming, flexible impeller pump flange mounted to DC motor 12/24 V Typical applications Bilge pump, fresh water pump, deck washing, fuel oil transfer, fire pump, etc. F3B-19 Oil Change: Pump for permanent installation near the boat engine. To be used for the draining/filling of engine oil. Flow direction is easily changed with the integrated reversing switch. Technical description F2P10 Body: PTMT, Termoplastic polyester Brass Wearplates: AISI 316, stainless steel Impeller: NBR (nitrile) rubber Seal: Lipseal, NBR (nitrile) rubber O-ring: NBR (nitrile) rubber Connections: ½” hose R½” or ½”-14...

 Open the catalog to page 9
FIP DC F2P10-19, F3B-19, F38B-19, F4B-19 manual ‖ EN, DE, ES, FR, IT, SV-10

> English Pressure and capacity data (based on water at 20°C and at full voltage of the motor, 12.0 / 24.0 V unless specified otherwise) F2P10-19 Continous duty Intermittent duty Fuse required Fuse required Fuse required Intermittent duty Continous duty Warm oil increases the flow and decreases the power consumption Fuse required Installation and maintenance Installation General: Pump may be mounted in any position without loss of efficiency; however, it is suggested that the pump head be down if vertical mounting is desired. Mount motor as close as possible to power source to obtain full voltage....