EasyFlow FAST AND EASY GAUGING METHOD • • • • • • • Gauging by tracer dilution method In few minutes On stream with a good swirling up to 50’000 l/s Operates with cooking salt Measure by integration of the salinity Non polluting tracer Recording and visualisation of the gauging curve on PC Taking profit of the experience done with the SalinoMADD, EasyFlow is a simple-to-use gauging device for users who occasionally effectuate flow measurements and don’t want to do a too big investment. It permits to realize in few minutes the measurement of the flow of a stream thanks to the tracer dilution method. The tracing The conductivity probe is placed into the watercourse. Upstream, at a sufficient distance to assure a good mix of the tracer in the water, a known quantity of salt is injected, beforehand diluted in stream water into a container (about 10 grams per l/s of estimated flow). During the passing of the salt cloud, it records the salinity values of the water. When this cloud has passed, the flow of the watercourse is calculated and displayed in litres by seconds. Software EasyViewer The software EasyViewer for PC is furnished with the EasyFlow. It permits the downloading of measurement data, then the visualisation and the processing of the gauging curve. Additional information as the limnimetric height can be also saved with data in file. To verify the efficiency of the gauging, the recorded data in the EasyFlow can be uploaded into a PC. Then it is possible to visualise these data graphically. Some tools are available to recalculate the flow measurement by changing parameters or to print the result and the curve as presented below. MADDTechnologies sàrl – Avenue des Sports 42 – CH-1400 Yverdon-les-Bains – Switzerland Tel: +41 24 445 31 16 – Fax: +41 24 445 21 23 – Email: info@madd.ch – www.madd.ch
Open the catalog to page 1Technical Specifications Device Gauging range Gauging accuracy < 5 % (with optimum mix of tracer) Gauging repeatability Tracer type Cooking salt (NaCl) Tracer quantity Between 5 and 20 g of salt per l/s of estimated flow. (Ex : ~300 l/s -> 2 kg) 3 x 1,5V alkaline batteries, AA, LR6 type About 100 hours under normal conditions Dimensions / weight Complete bag : 260 x 190 x 130 mm / 1240 g Device with probe : 230 x 150 x 80 mm / 620 g Salinity Measuring range Temperature Measuring range can change these specifications without warning MADDTechnologies sàrl – Avenue des Sports 42 – CH-1400...
Open the catalog to page 2All JDC Electronic catalogs and brochures
-
Havilland Watches
5 Pages
-
Skywatch Products
6 Pages
-
MagnetTrans
1 Pages
-
SalinoMADD
2 Pages
-
Skywatch Atmos
2 Pages
-
AWS / WWS
2 Pages
-
N.E.W.S.
2 Pages
-
AERO
2 Pages
-
SKYWATCH EOLE ET METEOS
2 Pages
-
SPEEDWATCH
2 Pages
-
FLOWATCH
2 Pages
-
SKYWATCH GEOS
2 Pages
-
Xplorer
2 Pages