Rinnova ..2.0
19Pages

{{requestButtons}}

Catalog excerpts

Rinnova ..2.0 - 1

2.0 RINNOVA VERTICAL DC INVERTER COMPRESSOR Maximum comfort with the lower consumption and quiet operation. Renewal air and filtration air, with ePM1 80% filters. AIR QUALITY CONTROL Through the CO2, VOC, temperature and humidity sensors, it automatically adjusts the operation of the unit. WIFI REMOTE CONTROL

Open the catalog to page 1
Rinnova ..2.0 - 2

2.0 RINNOVA VERTICAL CONTINUOUS AIR RENEWAL INTEGRATED AIR QUALITY, HUMIDITY AND SIMPLE AND ADVANCED CONTROLS TEMPERATURE SENSORS WITH INTEGRATED WIFI Integrated touch-screen Handset control Smart touch WIFI or ModBus remote control (optional) FILTRATION WITH EFFICIENCY CLASS ePM1 80% VERTICAL OUTBLOW

Open the catalog to page 2
Rinnova ..2.0 - 3

2.0 RINNOVA VERTICAL Thermodynamic heat recovery ventilation unit Standard supply: • soft touch control display on the unit with integrated WIFI handset remote contol installation template wall fixing bracket DN 160 external grilles kit, internal flanges and plastic protection film external anti bypass covers

Open the catalog to page 3
Rinnova ..2.0 - 4

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Size Fresh air flow rate B/3/2/1 (1) Static pressure available (2) Total heating capacity (3) Space heating capacity wihout fresh air load (3) (4) Total power input (3) HEATING PERFORMANCE COOLING PERFORMANCE Total cooling capacity (5) Space cooling capacity wihout fresh air load (5) Total power input (5) GENERAL FEATURES Fans Fans Quantity Radial / Radial Heat recovery Compressor Filters Sound pressure (6) ELECTRICAL DATA Max Fans power input Max Compressor power input Max Total power input Connections diameter Condensate drain Heating -...

Open the catalog to page 4
Rinnova ..2.0 - 5

2.0 RINNOVA VERTICAL BUILT IN DC INVERTER COMPRESSOR Maximum comfort with the lower consumption and quiet operation. Renewal air and filtration air, with ePM1 80% filters. WIFI REMOTE CONTROL AIR QUALITY CONTROL Through the CO2, VOC, temperature and humidity sensors, it automatically adjusts the operation of the unit.

Open the catalog to page 5
Rinnova ..2.0 - 6

2.0 RINNOVA VERTICAL BUILT IN CONTINUOUS AIR RENEWAL INTEGRATED AIR QUALITY, HUMIDITY AND SIMPLE AND ADVANCED CONTROLS TEMPERATURE SENSORS WIFI OR INTEGRATED MODBUS ALL ELEMENTS FOR STANDARD INSTALLATION, DUCTABLE FRESH AIR FLOW INCLUDING EXTERNAL GRILLS DN 160

Open the catalog to page 6
Rinnova ..2.0 - 7

2.0 RINNOVA VERTICAL BUILT IN Thermodynamic heat recovery ventilation unit Note: ECA031II or ECB031II or ECA032II or ECB032II. wall control is mandatory for correct operation. Standard supply: • installation template wall fixing bracket DN 160 external grilles kit, internal flanges and plastic protection film external anti bypass covers adjustable feet

Open the catalog to page 7
Rinnova ..2.0 - 8

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Size 2.0 RINNOVA VERTICAL BUILT IN u.m. 30 (2) Static pressure available on fresh air delivery. It is possile to set the fan at the nominal static pressure available or at the max static pressure available. AIR FLOW RATE Fresh air flow rate B/3/2/1 (1) Total heating capacity (3) Space heating capacity wihout fresh air load (3) (4) Total power input (3) Static pressure available nominal/max (2) HEATING PERFORMANCE COOLING PERFORMANCE Total cooling capacity (5) Space cooling capacity wihout fresh air load (5) Total power input (5) Fans...

Open the catalog to page 8
Rinnova ..2.0 - 9

2.0 RINNOVA CEILING DC INVERTER COMPRESSOR COSTANT AIR FLOW FANS Maximum comfort with the lower consumption and quiet operation. Centrifugal fans with constant flow that automatically adapt the speed to the pressure drops of the ducts. AIR QUALITY CONTROL Through the CO2, VOC, temperature and humidity sensors, it automatically adjusts the operation of the unit. WIFI REMOTE CONTROL

Open the catalog to page 9
Rinnova ..2.0 - 10

remote control (optional)

Open the catalog to page 10
Rinnova ..2.0 - 11

Standard supply: • Front view Rear view handset remote contol Thermodynamic heat recovery ventilation unit soft touch control display on the unit with integrated WIFI installation template DN 160 external grilles kit, internal flanges and plastic protection

Open the catalog to page 11
Rinnova ..2.0 - 13

TECHNICAL SPECIFICATIONS (1) B = booster, V3 = nominal flow at maximum speed, V2 = medium speed flow, V1 = flow at minimum speed TECHNICAL SPECIFICATIONS Size (2) Static pressure available on fresh air fan (from outdoor grille to indoor delivery grille) and exhaust air fan (from exhaust intake grille to outdoor expulsion grille). The fans maintain the constant air flow between 0 Pa and 130 Pa. AIR FLOW RATE Fresh air flow rate B/3/2/1 (1) Static pressure available nominal/max (2) (3) Heating capacity at nominal air flow. Outdoor air temperature -5 °, relative humidity 80%. Ambient...

Open the catalog to page 13
Rinnova ..2.0 - 14

2.0 RINNOVA DUCT DC INVERTER COMPRESSOR COSTANT AIR FLOW FANS Maximum comfort with the lower consumption and quiet operation. Centrifugal fans with constant flow that automatically adapt the speed to the pressure drops of the ducts. AIR QUALITY CONTROL Through the CO2, VOC, temperature and humidity sensors, it automatically adjusts the operation of the unit. WIFI REMOTE CONTROL

Open the catalog to page 14
Rinnova ..2.0 - 15

FALSE CEILING INSTALLATION

Open the catalog to page 15
Rinnova ..2.0 - 16

Front view Rear view Standard supply: • installation template DN 160 external grilles kit, internal flanges and plastic protection fil

Open the catalog to page 16
Rinnova ..2.0 - 17

TECHNICAL SPECIFICATIONS (1) B = booster, V3 = nominal flow at maximum speed, V2 = medium speed flow, V1 = flow at minimum speed TECHNICAL SPECIFICATIONS Size (2) Static pressure available on fresh air fan (from outdoor grille to indoor delivery grille) and exhaust air fan (from exhaust intake grille to outdoor expulsion grille). The fans maintain the constant air flow between 0 Pa and 130 Pa. AIR FLOW RATE Fresh air flow rate B/3/2/1 (1) Static pressure available nominal/max (2) (3) Heating capacity at nominal air flow. Outdoor air temperature -5 °, relative humidity 80%. Ambient...

Open the catalog to page 17
Rinnova ..2.0 - 18

2.0 RINNOVA VERTICAL BUILT IN AERAULIC ACCESSORIES Insulated flexible hose DN 160 Double connection plenum DN160 + n ° 1 cap Double row supply grille Intake grille with removable filter Air flow – Static pressure available fresh air supply fan 2.0 RINNOVA VERTICAL BUILT IN Static pressure available (Pa) Fan set at the nominal static pressure available Fan set at the MAX static pressure available

Open the catalog to page 18
Rinnova ..2.0 - 19

2.0 RINNOVA DUCT AERAULIC ACCESSORIES Insulated flexible hose DN 160 Double row supply grille Intake grille with removable filter Static pressure available (Pa) Air flow – Static pressure available fresh air supply and intake exhaust air fan 2.0 RINNOVA DUCT

Open the catalog to page 19

All Itec Luchtreiniging catalogs and brochures

  1. UltraFog

    7 Pages

  2. FogMax

    7 Pages

  3. FOG 360

    7 Pages

  4. FOG50

    5 Pages