Inorganic Zinc Silicate INTENDED USES A two pack inorganic zinc-rich silicate based primer providing good abrasion resistance and outstanding corrosion protection for correctly prepared steel surfaces. Contains 82% zinc in the dry film for long term corrosion A primer for a wide range of above water organic coating schemes to greatly enhance corrosion resistance. For use at Newbuilding or Maintenance & Repair. Part B (Curing Agent) Volume Solids Typical Film Thickness Theoretical Coverage Flash Point Induction Period 1 weight(s) Part A to 2.86 weight(s) Part B 417 ft2/US Gal at 3 mils dft, allow appropriate loss factors. * Coverage rates are calculated based upon volume solids test (ISO 3233:1998) determinations. Conduct usage rate observation for best determination of actual coverage. Airless Spray, Conventional Spray Part A 67°F; Part B Non-infamable; Mixed 70°F (Setaflash) (ASTM D-3278) Touch Dry [ASTM D1640 7.5.1] 30 mins Overcoating Data - see limitations Substrate Temperature Note Overcoating is dependent upon ambient conditions. The figures above have been determined at the quoted temperature REGULATORY DATA 340 g/lt (2.83 lbs/US gal) as supplied (EPA Method 24) Note: VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in color and normal manufacturing tolerances. Complies with: SSPC Paint Specification No.20 Type 1C Referto Chapter 631 - Naval Ships Technical Manual, Paragraph Marine Coatings
Open the catalog to page 1Inorganic Zinc Silicate SYSTEMS AND Consult your International Paint representative for the system best suited for the surfaces to be protected. SURFACE Paint only clean, dry surfaces. Remove all grease, oil, soluble contaminants and other foreign matter by "solvent Dependent on yard procedures. Consult International Paint. For optimum performance "Near White Blast Cleaning" (SSPC-SP10) is recommended. Surface profile should be between 2 mils and 2.5 mils. Shop Primed Surfaces: Consult your International Paint representative for specific recommendations. Prior to overcoating, Interzinc 22...
Open the catalog to page 2Inorganic Zinc Silicate Airless Spray Conventional Spray Apply by conventional spray or airless spray. When spraying, pressure (material) tank must be located above or on the same level as work, material hoses should be extended full length - avoid loops, sags and coils. Allow for losses due to surface irregularities and application methods. Strain material through a minimum 60 mesh screen before application. Apply 3.8 mils wet which will yield 3.0 mils dry film thickness. Consult the following equipment recommendations or utilize suitable equal. Note: Do not apply in excess of 5.0 mils dry...
Open the catalog to page 3Inorganic Zinc Silicate Apply in good weather when air and surface temperatures are above 41 °F. Surface temperatures must be at least 5° F above dew point. For optimum application properties, bring material to 70-81 °F prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage between 40 and 95°F. Care should be taken at temperatures close to freezing that surfaces are free from ice. At relative humidities below 50%, curing will be severely retarded and humidity may need to be increased by use of steam or water spraying. For high...
Open the catalog to page 4All International Marine catalogs and brochures
-
Intergard 5000
4 Pages
-
Formula 150 (MIL-DTL-24441)
4 Pages
-
Interline 975P
4 Pages
-
Interline 994LT
4 Pages
-
Interline 644
4 Pages
-
Interspeed 5617
4 Pages
-
Intersmooth 7670 SPC
4 Pages
-
Interflex 8700 SPC
4 Pages
-
Interplate Zero
4 Pages
-
Intergard 269
4 Pages
-
Interline 850
4 Pages
-
Intersleek 1100SR
4 Pages
-
Intersmooth 7465HS SPC
4 Pages
-
Intersleek 717
4 Pages
-
Interfine 878
4 Pages
-
Intershield 456
4 Pages
-
Intershield 851
4 Pages
-
Intershield 852
4 Pages
-
Intershield 803Plus
4 Pages
-
Intercept 8500LPP PIC
2 Pages
-
Intercept 7000
1 Pages
-
Interbond 808
2 Pages
-
Integard 5555 PIC
2 Pages
-
Silyl acrylate antifoulings
2 Pages
-
Intertrac Vision
4 Pages
-
Intersleek 7180 Linkcoat
6 Pages
-
Intersleek 1000
6 Pages
-
Intershield 5150LWT
2 Pages
-
Intershield 300
8 Pages
-
Interline 9001
6 Pages
-
Interflex 8700 PIC
2 Pages
-
Fisheries
2 Pages
-
Interline 904
2 Pages
-
Intershield 6GV
2 Pages
-
Intershield One-2-One
1 Pages
-
Intersleek 700
2 Pages
-
Interswift 6600
2 Pages
-
Interswift 6800HS
2 Pages
-
Intergard 5400 PIC
2 Pages
-
Interspeed-5640
2 Pages
-
INTERSHIELD 803 DATA SHEET
4 Pages
-
Intershield 300V
4 Pages
-
Intergard 821
4 Pages
-
Intertherm 50
4 Pages
-
INTERTHERM 891 DATA SHEET
4 Pages
-
Intergard 403
4 Pages
-
Universal Primer Range
2 Pages
-
Intersleek
6 Pages
-
Cargo Tank Coatings
7 Pages
-
Antifouling coatings range
8 Pages
-
Cargo Hold Coatings
7 Pages
-
Keeping your fleet protected
6 Pages
-
Intershield_163_Inerta
9 Pages
-
Intercept 8000 LPP
4 Pages
-
Interswift 6900Si
4 Pages
-
Intergard 7500
2 Pages
-
Intergard 7020
2 Pages
-
Intergard 5600 / 5620
2 Pages
-
Interline®9001
5 Pages
-
Interplate® Zero
11 Pages
-
Intersleek7180Brochure
2 Pages
-
Hydroblasting Standards
8 Pages
-
Hydroblasting Standards
15 Pages
-
Maintenance and Repair
19 Pages
-
Slurryblasting Standards
14 Pages
-
Cargo Hold
8 Pages
-
Abrasive Sweep Standards
12 Pages
-
Colour Card
2 Pages
-
Interprime 65
4 Pages
-
Interline 104
4 Pages
-
Intersleek 386
4 Pages
-
Intersleek 737
4 Pages
-
Intersleek 970
4 Pages
-
Intersmooth 360 SPC
4 Pages
-
Intersmooth 7460HS SPC
4 Pages
-
Intersmooth 7465Si SPC
4 Pages
-
Interspeed 6400
4 Pages
-
Interswift 655
4 Pages
-
Intertuf 362
4 Pages
-
Intershield 163 Inerta 160
4 Pages
-
Intersmooth 365 SPC
4 Pages
-
Interswift 455FB
4 Pages
-
INTERLAC 678
4 Pages
-
INTERGARD 400
4 Pages
-
INTERFINE 629HS
4 Pages
-
INTERZONE 1000 DATA SHEET
4 Pages
-
INTERTUF 203 DATA SHEET
4 Pages
-
INTERTHANE 990
4 Pages
-
INTERSHEEN 579 DATA SHEET
4 Pages
-
INTERLAC 665 DATA SHEET
4 Pages
-
INTERGARD 7600 DATA SHEET
4 Pages
-
INTERBOND 501
4 Pages
-
INTERZINC 22 DATA SHEET
4 Pages
-
INTERTUF 262 DATA SHEET
4 Pages
-
INTERSHIELD 300 DATA SHEET
4 Pages
-
INTERPRIME 198
4 Pages
-
INTERGARD 5600 DATA SHEET
4 Pages
-
BALLAST TANK BROCHURE
13 Pages
Archived catalogs
-
Intergard 343
9 Pages