Intershield 456 - 1

Intershield 456 Epoxy Primer PRODUCT DESCRIPTION A high solids epoxy primer. Developed to meet the requirements of MIL-PRF-24667, Types I, II and V, Composition G and L primer system. INTENDED USES For use at Newbuilding, Maintenance & Repair or On Board Maintenance. A primer for Intershield 6GV, Intershield 6LV or Intershield 5150LWT non-skid deck coatings. PRODUCT INFORMATION Part B (Curing Agent) Volume Solids 3 volume(s) Part A to 1 volume(s) Part B Typical Film Thickness 5 mils dry (6 mils wet), 4 - 7 mils dry practical range equivalent to 4.8 - 8.3 mils wet Theoretical Coverage 269 ft²/US gal at 5 mils dft, allow appropriate loss factors Airless Spray, Brush, Roller Flash Point Part A 110°F; Part B 126°F; Mixed 110°F Induction Period 15 minutes at temperatures below 73°F Drying Information Overcoating Data - see limitations REGULATORY DATA Drying times and pot life will vary with ambient temperature and/or humidity changes. 120 g/lt (1.00 lb/US gal) as supplied (EPA Method 24) Note: VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in color and normal manufacturing tolerances. MIL SPEC Marine Coatings Page 1 of 4 Issue Date:2/4/2015 Ref:928 MIL-PRF-24667 Type VII, Composition G & L MIL-PRF-24667 Types I, II, V, Composit

Open the catalog to page 1
Intershield 456 - 2

Intershield 456 Epoxy Primer SYSTEMS AND COMPATIBILITY Consult your International Paint representative for the system best suited for the surfaces to be protected. Refer to International Paint Coating Application Procedures for additional information. TYPICAL SYSTEMS: Intershield 456/Intershield 6GV Intershield 456/Intershield 6GV/Interthane 990 Intershield 456/Intershield 6GV/Interthane 990HS Or Intershield 456/Intershield 6LV Intershield 456/Intershield 6LV/Interthane 990 Intershield 456/Intershield 6LV/Interthane 990HS Or Intershield 456/Intershield 5150LWT Intershield 456/Intershield...

Open the catalog to page 2
Intershield 456 - 3

Intershield 456 Epoxy Primer APPLICATION Apply by brush, roller or spray. Apply mixed material by brush, roller, or spray in an even coat to the properly prepared surface. Apply at 6 mils wet which will yield 5 mils dry film thickness. The recoat schedule must be adhered to. Surfaces must be abraded prior to applying additional coats if maximum recoat time has been exceeded. Consult the following equipment recommendations: Do not proportion material and do not mix until ready to use. Material is supplied in 2 containers as a unit. Always mix a complete unit in the proportion supplied. (1)...

Open the catalog to page 3
Intershield 456 - 4

Intershield 456 Epoxy Primer LIMITATIONS Apply in good weather when air and surface temperatures are above 50°F. Surface temperature must be at least 5°F above dew point. For optimum application properties, bring material to 70-80 °F prior to mixing and application. Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations. Technical and application data herein is for the purpose of establishing a general guideline of the...