Catalog excerpts
Alkyd Varnish INTENDED USES A one pack alkyd varnish with high gloss and good durability. For interior and exterior woodwork. For use at Newbuilding, Maintenance & Repair or On Board Maintenance. Part B (Curing Agent) Volume Solids Typical Film Thickness Theoretical Coverage Flash Point High Gloss 834 ft2/US gal at 1 mils dft, allow appropriate loss factors Airless Spray, Brush, Conventional Spray, Roller Drying Information Overcoating Data - see limitations Substrate Temperature REGULATORY DATA 373 g/lt (3.11 lb/US gal) as supplied (EPA Method 24) 400 g/kg of liquid paint as supplied. EU Solvent Emissions Directive (Council Note: VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in color and normal manufacturing tolerances. Marine Coatings
Open the catalog to page 1Alkyd Varnish SYSTEMS AND Consult your International Paint representative for the system best suited for the surfaces to be protected. SURFACE Use in accordance with the standard Worldwide Marine Specifications. PREPARATIONS A" surfaces to be coated should be clean, dry and free from contamination. High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning. NEWBUILDING/MAJOR REFURBISHMENT Ensure the wood is clean and dry prior to application. For new wood it is...
Open the catalog to page 2Alkyd Varnish Airless Spray Conventional Spray This material is a one pack coating and should always be mixed thoroughly with a power agitator before Not recommended. Use International GTA004 only in exceptional circumstances (max 15% by volume). DO NOT thin more than allowed by local environmental legislation. Total output fluid pressure at spray tip not less than 2500 psi (176 kg/cm2) Use suitable proprietary equipment. Thinning may be required. Thoroughly flush all equipment with GTA004. All unused material should be stored in tightly closed containers. Partially filled containers may...
Open the catalog to page 3Alkyd Varnish Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations. Apply in good weather. Temperature of the surface to be coated must be at least 5°F above the dew point. For optimum application properties bring the material to 70°F-81°F, unless specifically instructed otherwise, prior to mixing and application. Unmixed material (in closed containers) should be maintained in protected storage in accordance with...
Open the catalog to page 4All International Marine catalogs and brochures
-
Intergard 5000
4 Pages
-
Formula 150 (MIL-DTL-24441)
4 Pages
-
Interline 975P
4 Pages
-
Interline 994LT
4 Pages
-
Interline 644
4 Pages
-
Interspeed 5617
4 Pages
-
Intersmooth 7670 SPC
4 Pages
-
Interflex 8700 SPC
4 Pages
-
Interplate Zero
4 Pages
-
Intergard 269
4 Pages
-
Interline 850
4 Pages
-
Intersleek 1100SR
4 Pages
-
Intersmooth 7465HS SPC
4 Pages
-
Intersleek 717
4 Pages
-
Interfine 878
4 Pages
-
Intershield 456
4 Pages
-
Intershield 851
4 Pages
-
Intershield 852
4 Pages
-
Intershield 803Plus
4 Pages
-
Intercept 8500LPP PIC
2 Pages
-
Intercept 7000
1 Pages
-
Interbond 808
2 Pages
-
Integard 5555 PIC
2 Pages
-
Silyl acrylate antifoulings
2 Pages
-
Intertrac Vision
4 Pages
-
Intersleek 7180 Linkcoat
6 Pages
-
Intersleek 1000
6 Pages
-
Intershield 5150LWT
2 Pages
-
Intershield 300
8 Pages
-
Interline 9001
6 Pages
-
Interflex 8700 PIC
2 Pages
-
Fisheries
2 Pages
-
Interline 904
2 Pages
-
Intershield 6GV
2 Pages
-
Intershield One-2-One
1 Pages
-
Intersleek 700
2 Pages
-
Interswift 6600
2 Pages
-
Interswift 6800HS
2 Pages
-
Intergard 5400 PIC
2 Pages
-
Interspeed-5640
2 Pages
-
INTERSHIELD 803 DATA SHEET
4 Pages
-
Intershield 300V
4 Pages
-
Intergard 821
4 Pages
-
Intertherm 50
4 Pages
-
INTERTHERM 891 DATA SHEET
4 Pages
-
Intergard 403
4 Pages
-
Universal Primer Range
2 Pages
-
Intersleek
6 Pages
-
Cargo Tank Coatings
7 Pages
-
Antifouling coatings range
8 Pages
-
Cargo Hold Coatings
7 Pages
-
Keeping your fleet protected
6 Pages
-
Intershield_163_Inerta
9 Pages
-
Intercept 8000 LPP
4 Pages
-
Interswift 6900Si
4 Pages
-
Intergard 7500
2 Pages
-
Intergard 7020
2 Pages
-
Intergard 5600 / 5620
2 Pages
-
Interline®9001
5 Pages
-
Interplate® Zero
11 Pages
-
Intersleek7180Brochure
2 Pages
-
Hydroblasting Standards
8 Pages
-
Hydroblasting Standards
15 Pages
-
Maintenance and Repair
19 Pages
-
Slurryblasting Standards
14 Pages
-
Cargo Hold
8 Pages
-
Abrasive Sweep Standards
12 Pages
-
Colour Card
2 Pages
-
Interprime 65
4 Pages
-
Interline 104
4 Pages
-
Intersleek 386
4 Pages
-
Intersleek 737
4 Pages
-
Intersleek 970
4 Pages
-
Intersmooth 360 SPC
4 Pages
-
Intersmooth 7460HS SPC
4 Pages
-
Intersmooth 7465Si SPC
4 Pages
-
Interspeed 6400
4 Pages
-
Interswift 655
4 Pages
-
Intertuf 362
4 Pages
-
Intershield 163 Inerta 160
4 Pages
-
Intersmooth 365 SPC
4 Pages
-
Interswift 455FB
4 Pages
-
INTERGARD 400
4 Pages
-
INTERFINE 629HS
4 Pages
-
INTERZONE 1000 DATA SHEET
4 Pages
-
INTERZINC 22HS DATA SHEET
4 Pages
-
INTERTUF 203 DATA SHEET
4 Pages
-
INTERTHANE 990
4 Pages
-
INTERSHEEN 579 DATA SHEET
4 Pages
-
INTERLAC 665 DATA SHEET
4 Pages
-
INTERGARD 7600 DATA SHEET
4 Pages
-
INTERBOND 501
4 Pages
-
INTERZINC 22 DATA SHEET
4 Pages
-
INTERTUF 262 DATA SHEET
4 Pages
-
INTERSHIELD 300 DATA SHEET
4 Pages
-
INTERPRIME 198
4 Pages
-
INTERGARD 5600 DATA SHEET
4 Pages
-
BALLAST TANK BROCHURE
13 Pages
Archived catalogs
-
Intergard 343
9 Pages