Catalog excerpts
Intergard 821 Epoxy Filler PRODUCT DESCRIPTION A two pack epoxy filler. INTENDED USES For use as an anode shield and as a filler for pitted steel. For use at Newbuilding, Maintenance & Repair or On Board Maintenance. PRODUCT INFORMATION Part B (Curing Agent) Volume Solids 1.00 volume(s) Part A to 1 volume(s) Part B Typical Film Thickness 6000 microns dry (6000 microns wet) for use as an Anode Shield, up to 20,000 microns may be used as a filler Theoretical Coverage 0.17 m²/litre at 6000 microns dft, allow appropriate loss factors Flash Point (Typical) Part A 65°C; Part B 62°C; Mixed 62°C Induction Period Drying Information Overcoating Data - see limitations Overcoated By Intergard 821 Note REGULATORY DATA May be overcoated with Intergard and Intertuf products, consult International Paint for specific recommendations. 74 g/lt as supplied (EPA Method 24) 126 g/kg of liquid paint as supplied. EU Solvent Emissions Directive (Council Directive 1999/13/EC) 48 g/lt Chinese National Standard GB23985 Note: VOC values are typical and are provided for guidance purposes only. These may be subject to variation depending on factors such as differences in colour and normal manufacturing tolerances. Marine Coatings Page 1 of 4 Issue Date:04/12/201
Open the catalog to page 1Intergard 821 Epoxy Filler SYSTEMS AND COMPATIBILITY Consult your International Paint representative for the system best suited for the surfaces to be protected. SURFACE PREPARATIONS Use in accordance with the standard Worldwide Marine Specifications. All surfaces to be coated should be clean, dry and free from contamination. High pressure fresh water wash or fresh water wash, as appropriate, and remove all oil or grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning. ANODE SHIELDS NEWBUILDING/MAJOR REFURBISHMENT Where necessary, remove weld...
Open the catalog to page 2Intergard 821 Epoxy Filler APPLICATION Other Knife or Trowel Combine 1 part EAA820 with 1 part EAA821 by volume and thoroughly mix to a uniform colour. Mix only the amount that can be used within the pot life. Airless Spray Conventional Spray Work Stoppages and Cleanup Monitor material conditions, do not exceed pot life limitations. Clean all equipment immediately after use with International GTA822. In the event welding or flame cutting is performed on metal coated with this product, dust and fumes will be emitted which will require the use of appropriate personal protective equipment and...
Open the catalog to page 3Intergard 821 Epoxy Filler LIMITATIONS This product will not cure adequately below 5°C. For maximum performance the curing temperature should be above 10°C. In humid conditions, the surface of Intergard 821 may develop a "sweat" which must be washed off with fresh water before overcoating. Overcoating information is given for guidance only and is subject to regional variation depending upon local climate and environmental conditions. Consult your local International Paint representative for specific recommendations. Apply in good weather. Temperature of the surface to be coated must be at...
Open the catalog to page 4All International Marine catalogs and brochures
-
Intergard 5000
4 Pages
-
Formula 150 (MIL-DTL-24441)
4 Pages
-
Interline 975P
4 Pages
-
Interline 994LT
4 Pages
-
Interline 644
4 Pages
-
Interspeed 5617
4 Pages
-
Intersmooth 7670 SPC
4 Pages
-
Interflex 8700 SPC
4 Pages
-
Interplate Zero
4 Pages
-
Intergard 269
4 Pages
-
Interline 850
4 Pages
-
Intersleek 1100SR
4 Pages
-
Intersmooth 7465HS SPC
4 Pages
-
Intersleek 717
4 Pages
-
Interfine 878
4 Pages
-
Intershield 456
4 Pages
-
Intershield 851
4 Pages
-
Intershield 852
4 Pages
-
Intershield 803Plus
4 Pages
-
Intercept 8500LPP PIC
2 Pages
-
Intercept 7000
1 Pages
-
Interbond 808
2 Pages
-
Integard 5555 PIC
2 Pages
-
Silyl acrylate antifoulings
2 Pages
-
Intertrac Vision
4 Pages
-
Intersleek 7180 Linkcoat
6 Pages
-
Intersleek 1000
6 Pages
-
Intershield 5150LWT
2 Pages
-
Intershield 300
8 Pages
-
Interline 9001
6 Pages
-
Interflex 8700 PIC
2 Pages
-
Fisheries
2 Pages
-
Interline 904
2 Pages
-
Intershield 6GV
2 Pages
-
Intershield One-2-One
1 Pages
-
Intersleek 700
2 Pages
-
Interswift 6600
2 Pages
-
Interswift 6800HS
2 Pages
-
Intergard 5400 PIC
2 Pages
-
Interspeed-5640
2 Pages
-
INTERSHIELD 803 DATA SHEET
4 Pages
-
Intershield 300V
4 Pages
-
Intertherm 50
4 Pages
-
INTERTHERM 891 DATA SHEET
4 Pages
-
Intergard 403
4 Pages
-
Universal Primer Range
2 Pages
-
Intersleek
6 Pages
-
Cargo Tank Coatings
7 Pages
-
Antifouling coatings range
8 Pages
-
Cargo Hold Coatings
7 Pages
-
Keeping your fleet protected
6 Pages
-
Intershield_163_Inerta
9 Pages
-
Intercept 8000 LPP
4 Pages
-
Interswift 6900Si
4 Pages
-
Intergard 7500
2 Pages
-
Intergard 7020
2 Pages
-
Intergard 5600 / 5620
2 Pages
-
Interline®9001
5 Pages
-
Interplate® Zero
11 Pages
-
Intersleek7180Brochure
2 Pages
-
Hydroblasting Standards
8 Pages
-
Hydroblasting Standards
15 Pages
-
Maintenance and Repair
19 Pages
-
Slurryblasting Standards
14 Pages
-
Cargo Hold
8 Pages
-
Abrasive Sweep Standards
12 Pages
-
Colour Card
2 Pages
-
Interprime 65
4 Pages
-
Interline 104
4 Pages
-
Intersleek 386
4 Pages
-
Intersleek 737
4 Pages
-
Intersleek 970
4 Pages
-
Intersmooth 360 SPC
4 Pages
-
Intersmooth 7460HS SPC
4 Pages
-
Intersmooth 7465Si SPC
4 Pages
-
Interspeed 6400
4 Pages
-
Interswift 655
4 Pages
-
Intertuf 362
4 Pages
-
Intershield 163 Inerta 160
4 Pages
-
Intersmooth 365 SPC
4 Pages
-
Interswift 455FB
4 Pages
-
INTERLAC 678
4 Pages
-
INTERGARD 400
4 Pages
-
INTERFINE 629HS
4 Pages
-
INTERZONE 1000 DATA SHEET
4 Pages
-
INTERZINC 22HS DATA SHEET
4 Pages
-
INTERTUF 203 DATA SHEET
4 Pages
-
INTERTHANE 990
4 Pages
-
INTERSHEEN 579 DATA SHEET
4 Pages
-
INTERLAC 665 DATA SHEET
4 Pages
-
INTERGARD 7600 DATA SHEET
4 Pages
-
INTERBOND 501
4 Pages
-
INTERZINC 22 DATA SHEET
4 Pages
-
INTERTUF 262 DATA SHEET
4 Pages
-
INTERSHIELD 300 DATA SHEET
4 Pages
-
INTERPRIME 198
4 Pages
-
INTERGARD 5600 DATA SHEET
4 Pages
-
BALLAST TANK BROCHURE
13 Pages
Archived catalogs
-
Intergard 343
9 Pages