ingedrive.info@ingeteam.com The technical data in this catalogue is subject to change without prior notice. Frequency Converters
Open the catalog to page 1Frequency Converters Main Features With over 40 years' experience, Ingeteam's drives cover a wide range of applications in sectors such as Marine, Metals, Mining, Oil & Gas, Water & Waste Water, Power Generation, and Test Benches. Ingeteam designs and manufactures MV and LV variable speed drive solutions for the most demanding applications in terms of control requirements and environmental conditions. With the latest design in power electronics and control, Ingeteam offers an extensive portfolio of drives. Wide range of powers and voltages: the use of different types of semiconductor for...
Open the catalog to page 2Frequency Converters Topologies and Configurations The CCU communicates with the various BPMs (rectifiers and inverters) via an optic fibre link called PMM Link, thus electrically isolating the drive power side from control side and avoiding potential ground noise. It is designed for both basic solutions and highly-complex ones by expanding the number of I/Os locally and remotely and with the option of adding different communication modules. INGEDRIVE™ can be applied to different sectors and custom made to specific requirements. It can control motors with one or several windings and cater...
Open the catalog to page 3Frequency Converters Cooling Systems INGEDRIVE™ is easy to use via the operator panel and PC interface's powerful user-friendly software, which supports monitoring, configuration, diagnostics, control, data recording, and commissioning either locally or remotely when necessary. The system runs as a web application with no need for any additional software or license on your PC. Instead, once connected via the Ethernet link, the drive will supply your PC with the necessary software. Different password levels are available for data and parameter protection and data-program upload/download...
Open the catalog to page 4Frequency Converters Product Range INGEDRIVE™ offers different configuration options depending on your needs, such as non-regenerative systems, 6, 12, or 24-pulse DFE or AFE regenerative systems, as follows: · LV400 (low-voltage AC drive based on IGBTs. Air and water cooled) 6P DFE, 12P DFE, AFE as standard. · MV100 (medium-voltage AC drive, based on HV-IGBT modules. Air and water cooled) 12P DFE, 24P DFE, AFE as standard. · MV500 (medium voltage AC drive, based on IGCTs and water cooled) 12P DFE, 24P DFE, AFE as standard. · MV700 (medium voltage AC drive, based on HV-IGBT modules. Air...
Open the catalog to page 5Frequency Converters (1) Shaft power is calculated using asynchronous motor data ( =0.95, cos =0.89) (2) Shaft power is calculated using synchronous motor data ( =0.95, cos =1) (3) Excitation cabinet for synchronous motor not included
Open the catalog to page 6Frequency Converters water-cooled, low-voltage AFE Topology Rated Output Current (A) 996 1423 1707 Type Code Type Code (1) Shaft power is calculated using asynchronous motor data (η=0.95, cosϕ=0.89) (2) Shaft power is calculated using synchronous motor data (η=0.95, cosϕ=1) (3) Excitation cabinet for synchronous motor not included
Open the catalog to page 7Frequency Converters air or water-cooled, medium-voltage AFE Topology Motor Voltage V 3300 3300 3300 3300 4160 4160 4160 4160 Power Generation Fans & pumps. Shaft power is calculated using asynchronous motor data (η=0.965, cosϕ=0.9) Shaft power is calculated using synchronous motor data (η=0.965, cosϕ=1) Excitation cabinet for synchronous motor not included Fans included
Open the catalog to page 8Frequency Converters water-cooled, medium-voltage AFE Topology Motor Voltage V 3150 3150 3150 3150 3150 3150 3150 (1) Shaft power is calculated using asynchronous motor data (η=0.965, cosϕ=0.9) (2) Shaft power is calculated using synchronous motor data (η=0.965, cosϕ=1) (3) Excitation cabinet for synchronous motor not included air-cooled, medium-voltage 24 Pulse DFE Topology - Quadratic Loads Motor Voltage V 6600 6600 6600 6600 (1) (2) (3) (4) Shaft power is calculated using asynchronous motor data (η=0.965, cosϕ=0.9) Shaft power is calculated using synchronous motor data (η=0.965, cosϕ=1)...
Open the catalog to page 9Frequency Converters Environment and Health & Safety Management Ingeteam's strategy includes a permanent focus on achieving excellence in the quality that we provide and in process management, whilst constantly respecting the environment and considering safety as a priority. Hence, we are actively involved in the following: · Developing the EFQM model as an internal management reference. · Improving the satisfaction of our internal and external clients and suppliers. · Focusing on continuous improvement through the development of our certified and integrated management systems: 9001...
Open the catalog to page 10All Ingeteam Power Technology catalogs and brochures
-
SIPC
2 Pages
-
Power Grid Automation
2 Pages
-
IEC 61850
2 Pages
-
Ingeteam Press Release
5 Pages
-
INDAR Marine
2 Pages
-
IS 100TL
4 Pages
-
INGECON SUN 3Play TL U M
4 Pages
-
IS 3Play TL M
4 Pages
-
IS 1Play TL M
4 Pages
-
1000Vdc B Series
4 Pages
-
1500Vdc B Series
4 Pages
-
Wind power energy
32 Pages
-
Integrated Marine Solutions
32 Pages
-
INGEDRIVE MV500
2 Pages
-
INGEDRIVE LV400
2 Pages
-
INGEDRIVE MV100
2 Pages
-
INGEDRIVE DC200
2 Pages