TNF Ceiling C46 - Components The TNF continuous ceiling system consists of the following components: Ceiling tiles Fire class B15 Dimensions mm 600 x 600 70 Weight incl. profiles Surface 13,0 kg/sqm Thickness mm TNF Magic-faced steel and Rockwool slab 600 mm Standard tile 600 mm 70 mm The tiles are marked for proper installation Grid system Standard lenght Height from steel deck to mm surface of ceiling tile. Average consumption of parts per sqm ceiling Part name Part code Cover profile Carrier Cross bar TNF 619 TNF 611 TNF 612 2400 3600 600 See below 1) 0,39 pcs/sqm 2,72 pcs/sqm Hanger -...

Open the catalog to page 2
TNF-Ceilings-C46 - 3

TNF Ceiling C46 – Components TNF top profiles Cover profile For TNF C46 ceilings, TNF top profiles shall be used. TNF top profiles are made of galvanized steel. TNF 619 decorative surface - Standard length: 2400 mm TNF 426 TNF 619 Hanger TNF 446 Galvanized steel Upper part: TNF 614 length: 240 mm TNF 615 length: 340 mm TNF 616 length: 440 mm TNF 617 length: 540 mm Lock pin: TNF 618 Lower part: TNF 613 length: 190 mm TNF 611 painted surface - Standard length: 3600 mm TNF 612 painted surface - Standard length: 600 mm TNF 614 TNF 615 TNF 616 TNF 617 TNF 611 TNF 618 Carrier and Cross bar TNF...

Open the catalog to page 3
TNF-Ceilings-C46 - 4

Planning and layout When planning the layout of the ceiling, certain requirements may have to be taken into consideration.A demand for a symmetrical layout in all or some of the rooms, the location of light fittings, ventilation units etc. may be decisive for the choice of layout.When no such special requirements exist, the layout that gives minimum waste and cutting of ceiling tiles shall be chosen. - room width 2600 mm consumes: 1 tile cut to 300 x 600 mm, 3 tiles 600 x 600 mm and 1 tile cut to 500 x 600 mm. On this basis recommended: is - room width 2900 mm consumes: 4 tiles 600 x 600 mm...

Open the catalog to page 4
TNF-Ceilings-C46 - 5

Quantity ”take-out” When the grid system is marked on the drawing for each room, the quantity “takeout” can be done simply by adding up the number of various parts of the grid system. When specifying the ceiling please observe the following: A. Ceiling tiles Specifications on the ceiling tiles must include the following: - Ceiling colour - Number of tiles (size 600 x 600 mm) B. Grid system Specifications on the grid system must include the following information: - The number of pieces required of each part in the grid system. - The colour of the grid system (if nothing is stated, the grid...

Open the catalog to page 5
TNF-Ceilings-C46 - 6

Installation procedure Step 1: Carriers - Fig. A These are placed parallel to the length of the room and spaced 600 mm apart so that the required ceiling tile layout is achieved. The total length of each carrier should be equal to the free distance between the walls less 10 mm (5 mm free space at each end). Two carriers are joined by a special tongue system which locks the profiles when pushed together . Ensure that the locking is correct and that the two profiles are alligned completely. When installing the carriers, it is important to ensure that the holes for the cross bars have the...

Open the catalog to page 6
TNF-Ceilings-C46 - 7

Installation procedure cross bars.

Open the catalog to page 7
TNF-Ceilings-C46 - 8

TNF is the complete high quality accommodation system for all marine interiors. The TNF system includes wall and ceiling panels, doors, floors and wetunits. TNF has been leading the development in marine interiors since 1973. The world famous TNF quality is demonstrated in the environment, which can be designed to provide the ideal conditions for all functions. TNF www.inexa.com info@inexa.com