Catalog excerpts
Load:Logic® nrsS Control Panels Master panel Tuesday 03/15/2018 COT Press ENTER to E!e<jir>
Open the catalog to page 1Load:Logics Control Paiwis 03:22:13 PM cm J’tvm FMIFft la fli-ji r,
Open the catalog to page 2Load:Logic® Panels , i 'i I I "" An ;! Save Time • Compact single enclosure includes relays, control functions and input terminals for low voltage devices. • All inputs are software assignable to any Hubbell low voltage input device including switches, occupancy sensors, and photocells. • LCD user interface incorporates easy to follow, intuitively configured tools. Meet Energy Efficiency Standards • Load:Logic Panels meet ASHRAE 90.1, IEEC, and California (CEC) Title 24 energy codes. • Load:Logic Panels contribute to LEED certification requirements. • Allows multiple low voltage inputs...
Open the catalog to page 3Hubbell Load:Logic® Panels Product Installation Features The Hubbell Load:Logic panels are self-contained load control systems. All inputs are low voltage and hard-wired to terminal blocks in the panel. Input power supply is multi-tapped for typical service voltages. Line voltage terminals are located with generous space for easy connection. Load:Logic Panel User Interface The easy to use and understand LCD Display with keypad has been designed based on input styles of commonly used devices, such as cell phones. Panel Door Lock The panel is designed to be locked once the qualified...
Open the catalog to page 4Auxiliary Input Features • Provisions for multiple device control of a single relay or group • Scenarios program allows for easy mapping of auxiliary inputs Dry Contact Output Features • Normally open or normally closed output • Momentary or maintained • Allows for interconnection to other building functions such as security, fire alarm, or building management system Relay Card Features • 1-pole and 2-pole relays fit in the same sized space • Relay self-identifies once installed • Available 20A/1P N/O, 20A/2P N/O or N/C and 30A/1P latching Dimming Card Features • Full range dimming with...
Open the catalog to page 5The easy to use color LCD display has been designed based on inputs used in common mobile devices and digital equipment. LCD Display Allows for most programming to be completed in a single screen. Right side scroll bars appear when more choices are available than currently visible. Alpha-Numeric Keypad This keypad is used to populate names and numeric values while programming. Keys Function Keys - These keys provide programming choices in various screens. Key labels appear on-screen when keys are available. Escape Key - This key takes the user to the previous screen. Warning prompts when...
Open the catalog to page 6The Scenarios programming feature allows the user to select from a group of pre-configured control schemes to easily assign relays and inputs for the desired actions. The use of Scenarios shortens configuration time by only requiring a unique input that assigns properties, masking and priorities to a predetermined operation mode. Indoor Scenarios: Outdoor Scenarios: • Manual Switch ON/Auto Occupancy Sensor OFF • Photocell ON/OFF/Override Switch • Switch-Occupancy ON/OFF/Photocell OFF • Astro ON/Schedule OFF/Override Switch INDOOR SCENARIOS Switch ON-OFF Motion Sensor ON-OFF Han SU...
Open the catalog to page 7Load:Logic® Control Panels Load:Logic® Stand Alone, Master and Secondary Panels The Hubbell Load:Logic Control Panels provide feature-rich and cost effective control for maximum energy savings. The LCD user interface is located in the door and utilizes simple and intuitive scrolling menus to configure, check status or update the panel. The easy to use Pre-Configurated Scenarios Menu makes project commissioning simple and fast. *not available as a master or secondary panel Control Panels Control Panels Control Panels Control Panels Control Panels Flexible Design Applications Load:Logic...
Open the catalog to page 8Ordering Information Selecting Load:Logic® - Easy as 1, 2, 3 Step 1 Select the control panel Step 2 Select the appropriate relays Step 3 Select the appropriate switches Step 4 Select a dimming card, if required Step 5 Select appropriate sensors Description Stand Alone Master Secondary Relay panel with space for field CP042RRR3 CP082RRR1 CP082RRR2 Description Master Secondary Master Secondary Relay panel with space for field CP162RRR1 CP162RRR2 CP242RRR1 CP242RRR2 installation, 120/277V AC Relay panel with space for...
Open the catalog to page 9Dimming Load:Logic Interface Card • Full range dimming with preset dimming levels • 30mA current sinking capacity per channel • Max Dim Level (Demand Response System Settings) • Operates with 0-10V dimmable ballasts • Eight dimming channels per card Interface Cards Description 8-channel dimming controller option board with manual and automatic control of dimming levels Dimming Switches (Use only with dimming card option)_ Color 1 button 2 button 3 button 4 button Ivory CPSD1I CPSD2I CPSD3I CPSD4IGray CPSD1GY CPSD2GY CPSD3GY CPSD4GY Light Almond...
Open the catalog to page 10Wall Mount Sensors • “Install and forget” operation • Swivel mounting bracket included for wall or ceiling mounting • All digital sensing technology • Photocell for daylight harvesting and relay interface with auxiliary systems such as HVAC (RP models) • 24V DC, 33mA • ASHRAE 90.1 and CEC Title 24 Compliant • cULus Dual (Ultrasonic and Passive Infrared) Description Coverage Color Catalog Number Low voltage sensor 32kHz with photocell and isolated relay 1600 sq. ft. Office White ATD1600WRP Passive Infrared Description Coverage Color Catalog Number Low voltage sensor...
Open the catalog to page 11Load:Logic® Control Panels Resources | Online Hubbell offers a landing page dedicated to energy savings. Be sure to visit the Hubbell Wiring-Device Kellems website for more information. Also Online | Literature Hubbell offers an extensive literature library for product support. Downloadable PDFs are available online. Load:Logic® Control Panels Installation Programming Guide PRECAUTIONS • READ AND FOLLOW ALL SAFETY INSTRUCTIONS. • CAUTION - RISK OF ELECTRICAL SHOCK. To prevent electrical shock, turn OFF power at the circuit breaker before installing or servicing unit. Never wire energized...
Open the catalog to page 12All Hubbell Marine Electrical Products catalogs and brochures
-
WIRING_HBL61CM65
1 Pages
-
WIRING_HBL23CM11
1 Pages
-
Wiring_Catalog_AA35
1 Pages
-
Wiring_Catalog_AA34
1 Pages
-
WIRING_HBL316B6W
1 Pages
-
WIRING_M4100B12R
1 Pages
-
Wiring_Catalog_AA25
1 Pages
-
WIRING_HBL26CM13
1 Pages
-
Wiring_Catalog_AA9
1 Pages
-
Wiring_Catalog_AA10
1 Pages
-
Watertight Devices
1 Pages
-
Straight Blade Plug
1 Pages
-
HUBBELL® Delivery Systems
17 Pages
-
Floor Boxes
1 Pages
-
Accessories
1 Pages
-
netSelect
1 Pages
-
Hubbell Marine Products
56 Pages
-
HBL332C6W
1 Pages
-
HBL332B6W
1 Pages
-
HBL316CRCX
1 Pages
-
12 Volt DC Rated Switches
1 Pages
-
IEC Pin and Sleeve Devices
2 Pages
-
Tamper-Resistant Receptacles
4 Pages
-
HBL26CM10
1 Pages
-
HBL316P6W
1 Pages
-
HBL316C6W
1 Pages
-
HBL316R6W
1 Pages
-
HBL316B6W
1 Pages
-
100 Amp Adapters
2 Pages
-
Marine Products
56 Pages
-
B-Line Electrical Products
4 Pages
-
Marine LED Cable Sets
2 Pages
-
Marine 12 Volt DC Switches
2 Pages
-
Marine 200 Amp Ship-to-Shore
2 Pages
-
30 Amp Marine Adapter
2 Pages
-
ELCI Interface Solutions
2 Pages
Archived catalogs
-
Marine Catalog
56 Pages