Product catalog summary
Specifications:
  • Back Carrier: 0.04mm PVC (Caliper method)
  • Total Applied Thickness: 0.99mm (Caliper method)
  • Total Thickness: 1.2mm (Caliper method)
  • Type of Adhesive: Solvent acrylic
  • Mineral Type: S2
  • Adhesion to Steel: 1500 g/25.4mm2 (PSTC-4)
  • Tensile Strength: 5.0 Kg/25.4mm2 (PSTC-31)
  • Elongation at Break: 5% (PSTC-31)
  • Temperature Range: -30ºC to +70ºC
  • Applied Weight: 800 g/m²
  • Maximum Size of Production Roll: 1060mm x 100m
  • Resistance to Water: 10 months (PSTC-35)
  • Resistance to Chemicals: 8 months (PSTC-35)
  • Resistance to Motor Oil: Excellent (PSTC-35)
  • Life Span: 12 to 24 months (PSTC-9)
Coefficient of Friction Data:
  • Dry Surface Test Result: 96 TRL
  • Wet Surface Test Result: 42 TRL

Tests conducted using the Pendulum method at an independent friction testing laboratory. Static test results available as per ASTM C 1028-96.

LRV Test Results:

Conducted following Lucideon In House Test Method WW22, compliant with BS.8493:2008+A1:2010.

  • H3460B (Blue): Average LRV 7, Range 4
  • H3460S (Grey): Average LRV 24.75, Range 3
  • H3460W (White): Average LRV 62, Range 4
  • H3460N (Black): Average LRV 0, Range 0
Notes:

All data is for reference only. Temperature tests were performed by Adhesive Technical Services Ltd, England. Certificates for friction tests are available upon request.

See more

Catalog excerpts

H3460 Marine Anti Slip Tape Data Sheet-1

ANTI-SUP SOLUTIONS [email protected] www.heskins.com 21/03/2022 The above tests were conducted in accordance with Pendulum, the tests were conducted at a recognised independent friction testing laboratory, and copy certificates are available on request. Pendulum is a dynamic test, for static tests we also have results ASTM C 1028-96.

 Open the catalog to page 1
H3460 Marine Anti Slip Tape Data Sheet-2

ANTI-SUP SOLUTIONS [email protected] www.heskins.com 21/03/2022 The test procedure follows Lucideon In House Test Method WW22, and complies with the requirements of BS.8493:2008+AI :2010. All the above data is for reference only.

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.