video corpo

Dampers - AL

Dampers - AL

Dampers - AL

Product catalog summary
Overview: This document provides detailed specifications and descriptions of various types of dampers used in ventilation systems, particularly for ships and offshore installations. The dampers are designed to control airflow, prevent backflow, and enhance safety by preventing the spread of fire, smoke, and gases.
Types of Dampers:
  • Fire and Gas Dampers: These dampers are crucial for preventing the spread of fire, smoke, and gas through ventilation ductwork. They are type-approved according to A-0 (A-60) standards and feature a hot-dip galvanized steel frame with blades filled with fire-resistant mineral wool.
  • Shut-off Dampers: Used to shut off airflow in ductwork, these dampers can serve as functional isolating dampers or as fire closures for main external ventilation openings, as required by SOLAS.
  • Smoke Dampers: Designed to prevent the spread of smoke and gases, these dampers have a steel casing with spiro pipe connections and a manually operated rotary flap.
  • Non-return Valves and Dampers: These are installed to prevent backflow of air through ventilation ducts. They operate by static air pressure and do not require actuators.
  • Air Flow Diffusers: These enable adjustment of the supplied air flow direction or closure of air supply, featuring a flanged casing with rotary shutter blades.
Materials and Construction: All dampers are constructed with hot-dip galvanized steel frames and blades, with options for stainless steel and marine paint preservation. The thickness of materials varies depending on the type of damper.
Operation and Control: Dampers can be controlled electrically, pneumatically, or manually. Fire and gas dampers close automatically in case of fire. Actuators used include Belimo and Schischek, with specific models for explosion-proof areas.
Certifications and Standards: The dampers comply with various international standards, including ISO 9001, and have been fire-tested according to IMO resolution A.754(18) 1994.
Contact Information: The document provides contact details for Heinen & Hopman offices worldwide, offering support and further information.
See more

Catalog excerpts

Dampers - AL-1

PROVIDED BY HEINEN & HOPMAN

 Open the catalog to page 1
Dampers - AL-2

DAMPERS There are different types of dampers: • Fire and gas dampers • Shut-off dampers • Smoke dampers • Non-return valves • Non-return dampers • Air-flow diffusers Fire and gas dampers Fire and gas dampers prevent the spread of fire, smoke and gas between ventilation ductwork, where people must have the maximum amount of time to react to possible fire. The dampers are type-approved according to A-0 (A-60). ALFD fire and gas dampers Frame: Hot-dip galvanized steel. Thickness: 3-5 mm. Blades: opposed blades filled with fire-resistant mineral wool sealed with thermal expanding gasket. Sizes: 100x100...

 Open the catalog to page 2
Dampers - AL-3

Non-return valves ALNV non-return valves are installed in ventilation ductwork of ships and off-shore objects to prevent the backflow of air through the ventilation ducts. Air flow diffusers ALAD air flow diffusers are installed in ventilation ductwork of seagoing ships and off-shore objects. ALAD air flow diffusers enable adjustment of the supplied air flow direction or the closing air supply. Classification ALFD Non-return dampers ALND non-return dampers are installed in ventilation ductwork of ships and off-shore objects to prevent the backflow of air through the ventilation ducts. ALAD air...

 Open the catalog to page 3
Dampers - AL-4

ALFD fire and gas dampers ALFD fire and gas dampers prevent the spread of fire, smoke and gas between the ventilation ductwork, where people must have the maximum amount of time to react to possible fire. The dampers are type-approved according to A-0 (A-60). The dampers have a flanged steel casing with opposed blades with thermal expanding gasket. The fail-safe is made by a thermal release device which operates if the temperature inside the duct increases above 72 °C (optionally 90 °C). If the power supply is interrupted, a spring return actuator closes the blade. The actual position of the...

 Open the catalog to page 4
Dampers - AL-5

ALSD smoke dampers ALCT shut-off dampers ALCT shut-off dampers shut off the airflow in ductwork. The dampers can be used as functional isolating dampers or as fire closure of main external ventilation openings as required by SOLAS. The dampers have a mild-steel frame and rotary blades actuated electrically, pneumatically or manually. The voltage or the working pressure of the control air must be specified at order. ALSD smoke dampers prevent the spread of smoke and gases through the pipework in case of fire. The dampers have a steel casing with spiro pipe connections on both ends and with a manually...

 Open the catalog to page 5
Dampers - AL-6

ALNV non-return valves ALNV non-return valves are installed in ventilation ductwork of ships and off-shore objects to prevent the backflow of air through the ventilation ducts. The valves must be installed horizontally or vertically. H B L G S Weight mm Performance chart (air static pressure that opens the flap) Hot-dip galvanized Stainless steel Stainless steel Alternatives available on request. Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

 Open the catalog to page 6
Dampers - AL-7

ALND non-return dampers ALND non-return dampers are installed in ventilation ductwork of ships and off-shore objects to prevent the backflow of air through the ventilation ducts. The dampers do not require an actuator or motor. The dampers must be installed horizontally or vertically. The dampers can be easily adjusted by adjusting the weight of each damper/installation or by adjusting the weights fitted to the blade shafts. The minimum opening force can be easily adjusted by the counterweights fitted to the blade shafts. • Standard construction places weights on the right-hand side. Weights...

 Open the catalog to page 7
Dampers - AL-8

UAE (Dubai) T: +971 4263 5453 E: [email protected] UsA - Fort Lauderdale, Florida T: +195 4463 0110 E: [email protected] UsA - Houma, Louisiana T: +198 5876 7989 E: [email protected] www.heinenhopman.com HEINEN & HOPMAN Heinen & Hopman encourages a more sustainable world. By providing eco-friendly solutions and services the option of reducing energy consumption and thus co2 emissions. Visit greenmanifest.info for more information.

 Open the catalog to page 8

Archived catalogs

  1. Cooling plant

    10  Pages

  2. Duct Heater

    10  Pages

  3. Unit heaters

    8  Pages