1. Catalogs
  2. HEADHUNTER INC.
  3. Sym-Z Fluid Level Sensor

Sym-Z Fluid Level Sensor

Sym-Z Fluid Level Sensor

Product catalog summary
Specifications:
  • SYM-ZR: Input voltage: 12-60VDC, Max Current: @12V 200mA @24V 100mA, Pressure range: 0-97 inches of H2O, Voltage output: 0.95 to 4.33 VDC, Burst Pressure: 100 PSI, Max Temp: 160°F (71°C), Enclosure Rating: NEMA 4X and IP66.
  • SYM-ZS: Input voltage: 12-60VDC, Max Current: @12V 200mA @24V 100mA, Pressure range: 0-32 inches of H2O, Voltage output: 0.5 to 4.10 VDC, Burst Pressure: 20 PSI, Max Temp: 160°F (71°C), Enclosure Rating: NEMA 4X and IP66.
  • SYM-ZM: Input voltage: 12-60VDC, Max Current: @12V 200mA @24V 100mA, Pressure range: 0-63 inches of H2O, Voltage output: 0.5 to 4.0 VDC, Burst Pressure: 20 PSI, Max Temp: 160°F (71°C), Enclosure Rating: NEMA 4X and IP66.
Product Overview:

The Headhunter SYM-Z series (R, M, & S) are tank level sensors designed to measure the hydrostatic head pressure of fluid in a tank vented to the atmosphere. They convert this pressure into an analog signal voltage output. These sensors are compatible with Headhunter Tank Sentry Panel models and various PLC and computer monitoring systems.

Recommendations:
  • SYM-ZR: Suitable for tanks 63 to 97 inches deep.
  • SYM-ZM: Suitable for tanks 32 to 63 inches deep.
  • SYM-ZS: Suitable for tanks less than 32 inches deep.
Installation and Operating Instructions:

Detailed instructions for installation and operation are provided to ensure proper setup and functionality of the tank level sensors.

See more

Catalog excerpts

Sym-Z Fluid Level Sensor-1

FLUID LEVEL MONITORS INSTALLATION AND OPERATING INSTRUCTIONS Specifications: 4 7/16” (113 mm) SYM-ZR Input voltage: 12-60VDC Max Current: @12V 200mA @24V 100mA P range: 0-97 inches of H20 V out: .95 to 4.33 VDC Replaces: SYM-3QR & SYM-23QR Burst Pressure: 100 PSI Max Temp: F= 160 deg (C= 71 deg) Enclosure Rating: NEMA 4X and IP66 SYM-ZM Input voltage: 12-60VDC Max Current: @12V 200mA @24V 100mA P range: 0-63 inches of H20 V out: .5 to 4.0 VDC Replaces: SYM-3QS & SYM-23QS Burst Pressure: 20 PSI Max Temp: F= 160 deg (C= 71 deg) Enclosure Rating: NEMA 4X and IP66 SYM-ZS Input voltage: 12-60VDC Max Current: @12V 200mA @24V 100mA P range: 0-32 inches of H20 V out: .5 to 4.10 VDC Replaces: SYM-3QS & SYM-23QS Burst Pressure: 20 PSI Max Temp: F= 160 deg (C= 71 deg) Enclosure Rating: NEMA 4X and IP66 The Headhunter SYM-Z(R,M & S) are tank level sensors that measure the hydrostatic head pressure of a column of fluid in a tank vented to atmosphere and convert the pressure into an analog signal voltage output. The SYM-Z(R,M & S) are designed to be used with Headhunter Tank Sentry Panel models WTS-1500B, TS-1501B, TS-2500B, WTS-1100B, TS-2000B, and the TS-3000 Series (1-6) as well as PLC and computer monitoring systems. The SYM-ZR is recommended for use on tanks 63 in - 97 inches deep. The SYM-ZM is recommended for use on tanks 32 in - 63 inches deep. The SYM-ZS recommended for use on tanks less than 32 inches deep. Regular Tank Sym 0-97” Depth 3380 SW 11th Avenue Fort Lauderdale, Florida 33315 Phone: +1 954-581-6996 Fax: +1 954-587-0403 Medium Tank Sym 0-63” Depth Shallow Tank Sym 0-32” Depth R TOILETS WATER PRESSURE WASTE TREATMENT FLUID MONITORING AND MUCH MORE

 Open the catalog to page 1

All HEADHUNTER INC. catalogs and brochures

  1. Aqua-Box

    2  Pages

  2. Tortuga

    1  Page

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.