Catalog excerpts
Eposeal 300 EPOXY BINDING PRIMER ¬ Excellent penetration of porous surfaces ¬ Ideal sealer coat before solvent-free epoxies ¬ Long pot life and easy application INTRODUCTION Eposeal 300 is a solvent-based, low viscosity epoxy sealer. It has been developed primarily for use on wood but can also be used on other materials such as GRP stone, ferrocement, brick, etc. Eposeal 300 has an extremely low , viscosity which ensures that the product achieves rapid and deep penetration of porous surfaces. Once Eposeal 300 material has soaked into a surface, the adhesive nature of the epoxy base will help to consolidate and strengthen that surface. The resultant epoxy sealing layer provides a high adhesion and moisture resistant base for any type of paint, varnish or epoxy coating system. For example, many woodworking applications combine the penetrating power of the Eposeal 300, with the thick, clear coating capability of SP 320 to produce a strong, highly protective, deep gloss surface on wood. The solvents used in Eposeal 300 evaporate quickly once the product is brushed out, so that subsequent layers of Eposeal 300 can be applied in quick succession. Providing the lid is replaced on the mixing pot, the long pot life of Eposeal 300 means that just one mix can be used for multiple coats.
Open the catalog to page 1INSTRUCTIONS FOR USE WORKSHOP CONDITIONS For optimum results Eposeal 300 should be used at between 10 - 25°C. It can be used at lower temperatures but the cure will be slower. As the relative humidity (RH) can affect coating quality it is important to ensure that the RH is below 70% in order to avoid surface blooming. The room should be well ventilated to aid solvent release. PIGMENTING Eposeal 300 is not suitable for use with Gurit epoxy pigments but polyester type pigment colours may be used. WOOD STAINING SURFACE PREPARATION All surfaces should be clean, dry and dust-free. Prior to...
Open the catalog to page 2PROPERTIES Component Properties Resin Shelf Life (months) Colour (Gardner) Mixed Colour (Gardner) Mixed Liquid Density (g/cm3) Solids Content (% by weight) Hazard Definition Cured System Properties Cured (28 days @ 21°C) Cured Density (g/cm3) Total Linear Shrinkage (%) Minimum Application Temperature Minimum Cure Temperature Typical Wet Film Thickness Typical Dry Film Thickness Solids Content (% by weight) sealing wood/porous surface coating wood Approx. Coverage (@50µm wet film thickness) (m2/L) Recommended Solvents** - spraying brushing cleaning 20 None required None required SP 302...
Open the catalog to page 3PROPERTIES (CONT’D) Working Properties vs Temperature Resin / Hardener 15°C Initial Mixed Viscosity (cP) †Latest Overcoating Time (hrs) †Earliest Sanding Time* (hrs) †Tack Off Time (hrs:mins) *If lid kept on mix pot to prevent solvent evaporation. Notes: For an explanation of test methods used see ‘Formulated Products Technical Characteristics’. All figures quoted are indicative of the properties of the product concerned. Some batch to batch variation may occur. † All times are measured from when resin and hardener are first mixed together. Latest Overcoating Time † Tack-off Time † Earliest...
Open the catalog to page 4HEALTH AND SAFETY The following points must be considered: 1. Skin contact must be avoided by wearing protective gloves. Gurit recommends the use of disposable nitrile gloves for most applications. The use of barrier creams is not recommended, but to preserve skin condition a moisturising cream should be used after washing. 2. Overalls or other protective clothing should be worn when mixing, laminating or sanding. Contaminated work clothes should be thoroughly cleaned before re-use. 3. Eye protection should be worn if there is a risk of resin, hardener, solvent or dust entering the eyes. If...
Open the catalog to page 5TRANSPORT & STORAGE The resin and hardener should be kept in securely closed containers during transport and storage. Any accidental spillage should be soaked up with sand, sawdust, cotton waste or any other absorbent material. The area should then be washed clean (see appropriate Safety Data Sheet). Adequate long term storage conditions for both materials will result in a shelf life of two years for both the resin and hardener. Storage should be in a warm dry place out of direct sunlight and protected from frost. The temperature should be between 10°C and 25°C. Containers should be firmly...
Open the catalog to page 6All Gurit catalogs and brochures
-
GURIT® BALSAFLEX™
4 Pages
-
CORECELL™ S
3 Pages
-
CORECELL™ T
3 Pages
-
GURIT® PVC
3 Pages
-
CORECELL™ A
3 Pages
-
SPABOND™ 345
7 Pages
-
SPABOND™ 730
4 Pages
-
Formulated Products Brochure
23 Pages
-
T-Prime 160
8 Pages
-
T-Prime 130-1 (v5)
8 Pages
-
SMARTCURE™ (v9)
4 Pages
-
System SPRINT™ Resin (v2)
4 Pages
-
T-Lam 130-1 Slow
6 Pages
-
T-Gel 130-1
6 Pages
-
T-Paste 70-2
6 Pages
-
CR 3400
5 Pages
-
Gurit® Kerdyn® Green
4 Pages
-
Marine Market Summary (v1)
2 Pages
-
Hetairos_Gurit_Project
2 Pages
-
Aerospace
2 Pages
-
PB1000
4 Pages
-
HI-PANEL
2 Pages
-
Gurit G-PET
1 Pages
-
GURIT PRODUCT CATALOGUE 2016
88 Pages
-
Ampreg 26
8 Pages
-
Ampreg 21FR
6 Pages
-
ST 95
6 Pages
-
PREPREGS
11 Pages
-
Hi-Panel Product Brochure
2 Pages
-
CORE MATERIALS
9 Pages
-
ADHESIVES
5 Pages
-
WE91 - 2
4 Pages
-
WE91 - 1
4 Pages
-
SE 85 GT
5 Pages
-
SE 85
5 Pages
-
SE 84 Nano
5 Pages
-
PH 840
4 Pages
-
PN 901
4 Pages
-
SE 300
4 Pages
-
SC 110
4 Pages
-
SE 200
5 Pages
-
ST 16
4 Pages
-
SE 84LV
6 Pages
-
ST 70
6 Pages
-
SE 70
5 Pages
-
SPABOND 340LV HT
6 Pages
-
SPABOND 345
4 Pages
-
SPABOND 340
7 Pages
-
SPABOND 340LV
6 Pages