Overview: GROCO gear pumps are positive displacement pumps designed for various on-board applications such as fuel transfer and engine oil change. They are not suitable for gasoline or other combustible fluids.
Installation: The pump should be installed in a dry location, centrally between two liquid sources if used as a transfer pump, and not more than 24 inches higher than the lowest source. Secure the pump with four 1/4" screws and flat washers. Double clamp hose connections or use thread tape on pipe connections. In-line valves may be installed to prevent fluid spills during service.
Electrical Installation: Use a dedicated circuit breaker and appropriate wire size as per the included chart. For GPBRR models, drill a 1/2" hole for the panel switch and use 18-gauge or larger marine-grade wire.
Operation: Different models have varying control mechanisms: GPB requires external switching, GPBR has a pump-mounted toggle switch, GPBRT features a touchpad control, and GPBRR includes a remote panel switch.
Maintenance: No regular maintenance is required, but annual inspections of plumbing and electrical connections are recommended. Winterization is necessary only if the pump is installed at or below the liquid level.
Parts and Service: A list of parts and service kits is provided for maintenance and repair. For assistance, contact the Vane Pumps Service Department at 410.604.3800 or visit www.groco.net.
See more

Catalog excerpts

GP SERIES-1

Info Sheet GP Series, 1 of 1 090501 Concept: GROCO gear pumps are positive sources. Double clamp hose connections displacement pumps, capable of operation in either direction. They may be used to perform a variety of on-board duties such as fuel transfer, engine oil change or ballast trim (DO NOT USE FOR GASOLINE or other combustible fluids). Installation: Install the pump in a dry location. If you are installing a reversing model as a transfer pump between two on-board tanks, locate the pump centrally between the two liquid sources, not more than 24" higher than the lowest of the two liquid 7 © 1999 GROSS MECHANICAL LABORATORIES, INC. ALL RIGHTS RESERVED. REV-B (VOLTAGE) REVERSING CONTROL (R MODELS) 1 REV-D ASSY REVERSING CONTROL (RT MODELS) 1 REV-E ASSY REVERSING CONTROL (RR MODELS) 1 If the pump is at or below the liquid source level, in-line valves (GROCO IBV-375 or FV-375) may be installed at both pump ports to prevent fluid spills during pump service. Installation, GPBRR: Drill 1/2" hole for the panel switch, and use 18-gauge or larger 3-conductor marine grade wire between pump and switch. Use crimp-on ring terminals at the pump terminal block. Orient the switch to match your pumping direction (port/starboard or fore/aft). Operation, GPB: No pump control is provided. The installer must provide switching. Operation, GPBR: Pump-mounted On-Off-On toggle switch is provided. Operation, GPBRT: Pump-mounted Touchpad Control is provided. Touchpad switching is momentary. Operation, GPBRR: On-Off-On momentary panel switch is supplied for control from a remote location. Electrical: The pump should be powered and protected by a dedicated circuit breaker of the proper capacity. Refer to the wire size selection chart included with this pump. Use the proper wire size for connections between the breaker to the pump. Maintenance: No regular maintenance is required. Annual inspection of plumbing and electrical connections should be made. Winterization: If the pump is installed above the liquid level, no winterization is required. If the pump is installed at or below the liquid level, drain the pump body by removing the cover plate. For service assistance/information call 410.604.3800 and ask for Vane Pumps Service Department. After hours, go to www.groco.net.

 Open the catalog to page 1

All Groco catalogs and brochures

  1. Thermopure-2

    6  Pages

  2. 200 SERIES

    1  Page

  3. G SERIES

    2  Pages

  4. PSR SERIES

    2  Pages

  5. PSR AC

    1  Page

  6. K SERIES

    1  Page

  7. HF SERIES

    1  Page

  8. TLM SERIES

    1  Page

  9. 155 SERIES

    1  Page

  10. HVL SERIES

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.