Catalog excerpts

CP-20-S SERIES-1

CP-20-S Centrifugal Circulator PumpInstallation, Operation, and Maintenance_ ©1999 GROSS MECHANICAL LABORATORIES, INC. ALL RIGHTS RESERVED. The Concept: CP-20-S is a submersible centrifugal pump designed for use in fresh or salt water (hot or cold) circulating systems. Construction is of bronze, stainless steel, or is non-metallic, so the pump may be used to pump nearly any non flammable, non-explosive liquid. Installation: Install the pump in a location that will provide generous air flow to aid in motor cooling. CP-20-S is not self-priming, so a flooded inlet is required. You may lay CP-20-S on its side in the bilge, running inlet and discharge hoses to and from the pump. Because of the weight of the pump, installation directly on top of a seacock is not recommended unless the pump is supported with straps or clamps. Bonding: GROCO pumps must be connected to the vessel bonding system. Use 14-gauge (or larger) stranded copper wire and a ring terminal beneath one of the bolts that holds the pump castings together to make this connection. Warning: Motorized equipment must have a separate connection to the vessel DC grounding bus in accordance with ABYC, E-11, Figure-18. DO NOT make pump bonding connection in series with non-motorized equipment such as strainers or seacocks. Plumbing: Make plumbing connections with pipe, hose, or pipe-to-hose adaptors. Double clamp hose connections and use TFE thread tape on pipe connections. The inlet is 3/4" NPT and the discharge is threaded internally 1/2" NPT, or 1" ID hose may be used. An adaptor is included for garden hose. Avoid sharp bends and sags in plumbing lines, and use full-flow fittings and hose if possible. Electrical: Proper wire size is essential for proper motor and pump performance. Refer to the wire size selection chart enclosed. The orange wire is positive (+). Make electrical connections with marine grade crimp terminals. Operation: Consider controlling operation with GROCO Pump Cycle Timer PC-10 or FPC-10 Maintenance: No regular maintenance is required. Winterization: Freezing water within will damage the pump. Close the inlet seacock and disconnect the connecting fittings or hose to drain water. For service assistance/information call 410.604.3800 and ask for Pumps Service Department. After hours, go to www.groco.net.

 Open the catalog to page 1

All Groco catalogs and brochures

  1. Thermopure-2

    6  Pages

  2. 200 SERIES

    1  Page

  3. G SERIES

    2  Pages

  4. GP SERIES

    1  Page

  5. PSR SERIES

    2  Pages

  6. PSR AC

    1  Page

  7. K SERIES

    1  Page

  8. HF SERIES

    1  Page

  9. TLM SERIES

    1  Page

  10. 155 SERIES

    1  Page

  11. HVL SERIES

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.