Probler Gun User Manual
32Pages

{{requestButtons}}

Catalog excerpts

Probler Gun User Manual - 2

ABOUT THIS MANUAL RELATED MANUALS PARTS REPLACEMENT PROCEDURE 18 Parts & Illustrations MIXING CHAMBER CHART 2 CLEANING DRILL CHART 2 FLAT SPRAY NOZZLES 3 SERVICE & REPAIR PARTS KITS 3 GUN HANDLE AIR PASSAGE LOCATIONS URETHANE FOAM EQUIPMENT ASSEMBLY INSTRUCTIONS PREOPERATION CHECK LIST OPERATING REQUIREMENTS INITIAL START-UP PROCEDURE SPRAY TECHNIQUE DAILY SHUT-DOWN PROCEDURE EXTENDED SHUT-DOWN PROCEDURE Options & Accessories PG-06 EXTERNAL MIXING CHAMBER KIT PG-10-XX FLAT SPRAY CONVERSION KIT INSTALLATION INSTRUCTIONS REPLACEMENT PROCEDURE Limited Warranty Policy If You Have An Equipment...

Open the catalog to page 2
Probler Gun User Manual - 3

About This Manual Before operating, maintaining or servicing any GlasCraft system, read and understand all of the technical and safety literature provided with GlasCraft products. If you do not have the proper or related manuals and safety literature for your GlasCraft system, contact your GlasCraft distributor or In this GlasCraft technical and safety publication, the following advisories will be provided where Is information about the procedure in progress. In order to provide our users with the most up-to-date technology possible, we are constantly seeking to improve products. If...

Open the catalog to page 3
Probler Gun User Manual - 4

PARTS & ILLUSTRATIONS Mixing Chamber Chart Outputs will vary with hose length, material viscosity and pressure. Chamber Assembly consists of: 1 Mixing Chamber Air Cap Seal 1 Mixing Chamber 1 Screw 2 Cleaning Drill Bit Cleaning Drill Chart

Open the catalog to page 4
Probler Gun User Manual - 5

Flat Spray Nozzles Chart NOTE: Nozzle size stated by Orifice Size and Degree of Spray Service & Repair Parts Kits

Open the catalog to page 5
Probler Gun User Manual - 6

GUN HANDLE AIR PASSAGE LOCATIONS & THREAD SIZES NOTE: All fractional dimensions recorded in inches.

Open the catalog to page 6
Probler Gun User Manual - 7

Mixing Chamber Shoulder Screw Mixing Chamber Button Head Valve Plug

Open the catalog to page 7
Probler Gun User Manual - 8

Connector Fitting Check Valve Body Check Valve Ball Assy. Mixing Chamber Check Valve Seal Assy. Check Valve Seal Retainer Mixing Valve Seal Shoulder Screw Filter Assy. Shoulder Screw Snap Ring Mixing Chamber Shoulder Screw Trigger Support Trigger Guard • Used with 17254-00, -01, -02, -03 Gun Assembly " Used with 17254-04, -05 Gun Assembly Button Head Screw

Open the catalog to page 8
Probler Gun User Manual - 9

Nozzle Connector Nozzle Seal Machine Screw Trigger Valve Piston Shaft Piston Assy. Retaining Ring

Open the catalog to page 9
Probler Gun User Manual - 10

Connector Fitting Check Val/e Body Check Valve Ball Assy. Mixing Chamber Side Block Check Valve Seal Assy. Check Valve Seal Retainer Shoulder Screw Snap Ring Filter Assy. Shoulder Screw Mixing Chamber Trigger Support Shoulder Srew Button Head Screw Trigger Guard •Used with 18374-00, -01, -02, -03 Gun Assembly '* Used with 18374-00, -04, -OS Gun Assembly

Open the catalog to page 10
Probler Gun User Manual - 11

Safe Handling And Use Of Urethane Foam Equipment Any tool, if used improperly, can be dangerous. Safety is ultimately the responsibility of those using the tool. In like manner, safe operation of polyester processes is the responsibility of those who use such processes and those who operate the equipment. This manual outlines procedures to be followed in conducting polyester operations safely. All personnel involved in dispensing operations should read and understand this manual. It is most important that equipment operators, maintenance, and supervisory personnel understand the...

Open the catalog to page 11
Probler Gun User Manual - 12

material should be re-sealed in the original container and stored in areas away from moisture. During clean-up of spilled isocyanate component, respirators, gloves and eye protection must be worn. Isocyanates which have been spilled can be controlled by covering them with dry sawdust and/or other absorbent, inert materials. Care should be taken to avoid skin contact. The absorbent material and the absorbed isocyanate should be collected promptly, placed in an open-top container, and treated with dilute solutions of ammoniom hydroxide and/or alcohol. While being treated in this manner, the...

Open the catalog to page 12
Probler Gun User Manual - 13

If you are now using Halogenated Hydrocarbon solvents in pressurized fluid systems having aluminum or galvanized wetted parts, IMMEDIATELY TAKE THE FOLLOWING STEPS: • Empty system, shut-off, completely depressurize in accordance with equipment service instructions. • Remove equipment from service, disassemble in accordance with equipment servicing instructions. • Inspect all parts for corrosion and/or wear. Replace any damaged parts. • Thoroughly clean all parts of the equipment with a non-halogenated solvent and reassemble in accordance with equipment servicing instructions. • Flush...

Open the catalog to page 13
Probler Gun User Manual - 14

quantities of warm salt water or warm soapy water. After vomiting, more water should be taken to dilute isocyanate further. CONTACT PHYSICIAN Hazardous concentrations of some chemical vapors exist before they can be smeiled. Chemical component suppliers should be contacted to determine at what concentrations the vapors of the chemicals they supply become dangerous, and the procedures and equipment needed to detect such dangerous concentrations. Such equipment should be obtained. Adequate ventilation must be provided in any area where foam chemicals are sprayed or poured, and wherever the...

Open the catalog to page 14
Probler Gun User Manual - 15

Refer to specific system user manual for complete system installation. Referto 17254 Gun illustration during instructions. Assembly Instructions 1. Connect Whip Hose, P/N 18006-00 to Hose assembly, P/N 19524-00 using Hose Union assembly, P/N 19434-00 and Air Line Fitting, After connecting, wrap Hose Union assembly and Air Line fitting with electrical tape to prevent electrical arcing or short circuiting. The Whip Hose assembly should now be attached to the Gun. The swivel fittings on the Whip Hose assembly are sized differently and will attach only one way. (Match like sized fittings.) Also...

Open the catalog to page 15
Probler Gun User Manual - 16

Refer to specific system user manual for complete system installation._ Preoperation Checklist Check that all fittings are securely tight Air Regulator turned to OFF position. Do not place any part of the body in the path of the material spray. Do not point the gun at or near other personnel. Do not look into the Mixing Chamber orifice at any Because of the hazardous materials used in this equipment, it is recommended that the operator use an air mask, goggles, protective clothing, and other safety equipment as prescribed • by current regulations, recommendations of the chemical suppliers,...

Open the catalog to page 16

All Graco catalogs and brochures

  1. FRP Chopper

    18 Pages

  2. G-Force II

    4 Pages

  3. Husky Grease

    9 Pages

  4. HV-2000 Jet

    24 Pages

  5. EcoQuip 2 EQm

    20 Pages

  6. Reactor® 2

    16 Pages

  7. Supply pumps

    8 Pages

  8. 300435Ej

    64 Pages

  9. 340712Ea

    8 Pages

  10. 320611Ea

    4 Pages

Archived catalogs

  1. MH User Manual

    68 Pages

  2. Brochure

    14 Pages