Introduction
The manual provides detailed guidance on the assembly, operation, maintenance, and service of the GlasCraft Indy Internal-Mix Low Emission Dispense Gun. It stresses the importance of understanding technical and safety literature before use, including advisories for equipment protection and personal safety.
Parts & Illustrations
Details on various parts and repair kits for the dispense gun are provided, including part numbers, descriptions, and quantities for components like O-rings and valve assemblies. Charts specify dispense tips and O-rings, detailing orifice sizes and materials.
Safety
Emphasizes safe operation of the polyester system, highlighting risks such as high-pressure liquid streams. It recommends consulting OSHA regulations and NFPA standards and using personal safety equipment.
Operation
Explains gun operation, daily maintenance, and parts replacement procedures with step-by-step servicing instructions and configuration options.
Technical Assistance
Users are advised to contact GlasCraft or distributors for support. The manual includes a limited warranty policy and encourages keeping the manual accessible.
Conclusion
The manual is a vital resource for efficient operation, longer service life, and easier troubleshooting of the GlasCraft dispense gun.
MEKP Handling and Safety
Guidelines for handling MEKP and other chemicals emphasize storage in cool, dry places away from heat and contamination. Safety measures include protective equipment and proper ventilation.
Clean-Up Solvents and Resin Diluents
Advises against using Halogenated Hydrocarbon solvents with aluminum or galvanized components due to explosion risks. Proper storage and handling are essential.
Catalyst Diluents
GlasCraft systems are designed to avoid catalyst diluents, reducing contamination and explosion risks. If necessary, handle with care as per supplier instructions.
Uncured Liquid Resin
Store resin in ventilated areas away from MEKP to prevent contamination and ignition.
Accumulation of Cured Laminate and Overspray
Regular removal of overspray and sandings is crucial to prevent fire hazards. Equipment maintenance and leak repairs are necessary for safety.
Toxicity and Chemical Injuries
Understanding chemical toxicity and having first aid measures in place is vital. Protective clothing and eyewear are recommended, with immediate medical attention for exposure.
Equipment Safety
Personnel should wear safety equipment and only trained personnel should operate or service the equipment. Avoid placing body parts near the spray gun fluid tip.
Emergency Stop Procedures
Instructions for stopping machinery and relieving pressure in emergencies are provided.
General Safety Precautions
Includes wearing protective eye equipment, maintaining material levels, stopping operations at the first sign of a leak, and inspecting hoses regularly.
Grounding
All conductive objects in the spraying area should be grounded to prevent static electricity, using AWG No. 18 stranded wire as a minimum.
Gun Operation and Maintenance
The Indy Gun is designed for reduced operator fatigue. Daily maintenance includes cleaning and inspecting for leaks, using genuine GlasCraft parts for repairs.
Parts Replacement Procedure
Flush and clean passages before assembly, replace O-rings, valves, and seals, and inspect parts for wear or damage.
Needle & Pin Removal and Reassembly
Follow specific procedures for needle assemblies, ensuring components are lubricated and properly assembled.
Trigger & Needle Guard Readjustment Procedure
Instructions for adjusting the set screw to ensure simultaneous needle activation, preventing LAG-LEAD in the mix.
Packing Nut Adjustment Procedure
Instructions for adjusting packing nuts to maintain proper gun function.
Options and Parts
Lists various parts and assemblies with part numbers and descriptions.
Warranty Information
GlasCraft provides a one-year warranty against defects, limited to the original purchaser, with conditions for notification of defects.
Technical Assistance
Contact information for technical support is provided, with a note to have equipment details ready.
Product Information
GlasCraft offers a range of spray systems and equipment for various applications.
See more

Catalog excerpts

Indy User Manual-1

DISPENSING EXCELLENCE DISPENSING EXCELLENCE INDIANAPOLIS, INDIANA Email [email protected]

 Open the catalog to page 1
Indy User Manual-2

Parts & Illustrations

 Open the catalog to page 2
Indy User Manual-3

About This Manual Before operating, maintaining or servicing any GlasCraft system, read and understand all of the technical and safety literature provided with GlasCraft products. If you do not have the prop- er or related manuals and safety literature for your GlasCraft system, contact your GlasCraft In this GlasCraft technical and safety publica- tion, the following advisories will be provided where appropriate: Is information about the procedure in progress. Is imperative information about equipment Is imperative information about personal safety. The information in this document is intended...

 Open the catalog to page 3
Indy User Manual-4

Parts & Illustrations MODEL 23550-00 INDY DISPENSE GUN Impingement Dispense Tips The J5 tip is furnished with the system only. For more information, contact your distributor, or GlasCraft Service Department. Material Airless Spray Tip Options: LPA2-147-XXXX. See small diameter airless tips option in the back of this manual. Repair Parts Kits:

 Open the catalog to page 4
Indy User Manual-5

Impingement Dispense Tips Airless Dispense Tips

 Open the catalog to page 5
Indy User Manual-6

O-Ring Chart EPRO Ring EPRO- Ring ilicone O-Ring ilicone O-Ring ilicone O-Ring Silicone O-Ring Silicone O-Ring Teflon O-Ring

 Open the catalog to page 6
Indy User Manual-7

1 ) Catalyst seat assembly p/n: 23544-00 2) Material seat assembly p/n: E-135 3) Material needle valve assembly p/n: 23545-00

 Open the catalog to page 7
Indy User Manual-9

1) 23546-00 resin check valve assembly. 2) 23547-00 catalyst check valve assembly. 3) 23016-02 solvent check valve body.

 Open the catalog to page 9
Indy User Manual-11

23550-00 Indy Parts List

 Open the catalog to page 11
Indy User Manual-12

Operating Your Polyester System Any tool, if used improperly, can be dangerous. Safety is ultimately the responsibility of those using the tool. In like manner, safe operation of polyes- ter processes is the responsibility of those who use such processes and those who operate the equip- ment. This manual outlines procedures to be fol- lowed in conducting polyester operations safely. This system has been specifically designed for use of Polyester Resin ,Gel-Coat ,and Methyl Ethyl Ke- tone Peroxides (MEKP) applications. Other formu- lations or blends considered for use in this equip- ment is strictly...

 Open the catalog to page 12
Indy User Manual-13

GlasCraft recommends that the user consult the state and local regulations established for all Safety equip- ment listed. 2.1 Hazards Associated with Laminating Operations The major hazards which should be guarded against in polyester laminating operations are those associated 1. The flammability and explosion dangers of the catalyst normally used - Methyl Ethyl Ketone Peroxide (MEKP). 2. The flammability dangers of clean-up solvents sometimes used (GlasCraft recommends that clean-up solvents be nonflammable), and of resin diluents used, such as styrene. 3. The flammability dangers of catalyst...

 Open the catalog to page 13
Indy User Manual-14

Safety in handling MEKP depends to a great extent on employee education, proper safety instructions and safe use of the chemicals and equipment. Workers should be thoroughly informed of the hazards that may result from improper handling of MEKP, especially in regards to contamination, heat, friction and impact. They should be thoroughly instructed regarding the proper action to be taken in the storage, use and disposal of MEKP and other hazardous materials used in the laminating In addition, users should make every effort to: with copious quantities of clean water and disposed of in accordance...

 Open the catalog to page 14
Indy User Manual-15

The reaction is unpredictable. Prior use of an HHC sol- vent without incident (corrosion or explosion) does NOT mean that such use is safe. These solvents can be dan- gerous alone (as a clean-up or flushing agent) or when used as a component or a coating material. There is no known inhibitor that is effective under all circumstances. Furthermore, the mixing of HHC solvents with other materials or solvents, such as MEK, alcohol, and tolu- ene, may render the inhibitors ineffective. The use of reclaimed solvents is particularly hazardous. Reclaimers may not add any inhibitors. Also, the pos- sible...

 Open the catalog to page 15
Indy User Manual-16

In your main plant, store only enough resin for one day's "NO SMOKING" signs must be posted and observed in all areas where resin is stored and/or used. Referto OSHA Section 1910.94, 1910.106, 1910.107 and consult resin suppliers for more detailed informa- Adequate ventilation (as covered in OSHA Section 1910.94 and NFPA No. 91) is important wherever sol- vents are stored or used, to minimize, confine and ex- haust the solvent vapors. Resin must never be stored in an area where MEKP is Open-top drums should not be used, due to possible contamination and possible catalyzation from overspray or...

 Open the catalog to page 16
Indy User Manual-17

Contact a doctor immediately in the event of any in- jury and give him the information you have collected. If your information includes first aid instructions, ad- minister first aid immediately while you are contact- Fast treatment of the outer skin and eyes that con- tact such chemicals generally includes immediate and thorough washing of the exposed skin and im- mediate and continuous flushing of the eyes with lots of clean water for at least 15 minutes or more. These general instructions of first aid treatment, however, may be incorrect for some chemicals; that is why you must know the chemicals...

 Open the catalog to page 17
Indy User Manual-18

3.2 General Safety Precautions The following general safety precautions should be followed when servicing or operating this equip ment to ensure operator safety: When filling catalyst container, protective eye equipment must be worn to protect against Always maintain adequate material levels to prevent loss of prime during system operation. At the first sign of a leak, stop operations, acti- vate emergency stop valve, back off air regula- tors and open all bleed valves to remove all pressure from the gun, hoses, pump, catalyst system and any other liquid containers. Solvent Pot Pressure Relief:...

 Open the catalog to page 18
Indy User Manual-19

Grounding an object means providing an adequate path for the flow of an electrical charge from the ob- ject to the ground. An adequate path is one that per- mits charge to flow from the object fast enough that it will not accumulate to the extent that a spark can be formed. It is not possible to define exactly what will be an adequate path under all conditions since it depends on many variables. In any event, the grounding means should have the lowest possible electrical resistance. Grounding straps should be installed on all loose conductive objects in the spraying area. This includes material...

 Open the catalog to page 19

All Graco catalogs and brochures

  1. FRP Chopper

    18  Pages

  2. G-Force II

    4  Pages

  3. Husky Grease

    9  Pages

  4. HV-2000 Jet

    24  Pages

  5. G-Force™ II

    4  Pages

  6. EcoQuip 2 EQm

    20  Pages

  7. AirPro EFX™

    8  Pages

  8. Reactor® 2

    16  Pages

  9. Supply pumps

    8  Pages

  10. 300435Ej

    64  Pages

  11. 340712Ea

    8  Pages

  12. 320611Ea

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.