Catalog excerpts
Wall Mount Horn/Strobe Low Profile Evacuation Horn/Strobe: VF4002-10 USCG Type Approved 161.002/A53/0 Standard Features - FM Approved, UL 464, UL 1971 & BFP Listed - Nominal voltage 24VDC - Units have field selectable candela options of 15, 30, 60, 75, and 110 candela - Super-SlideTM Bracket - Ease of Supervision Testing - CheckmateTM - Instant Voltage Verification - Unit Dimensions: 5” high x 4.5” wide x 2.5” deep - Synchronize Horn/ Strobe with Fireboy-Xintex Series Control Module - Prewire entire system, then install signals - Lower installation and operating costs - Input terminals 12 to 18 AWG - Switch selection for high or low dBA - Switch for chime, whoop, mechanical and 2400Hz tone - Tamperproof re-entrant grill - Switch for continuous or temporal 3 (not available on whoop tone) - Surface mount with the VF4005-10 (Fireboy-Xintex Surface Mount Box) - Silence horn while strobes remain flashing - Wide voltage range 16-33VDC or FWR (24VDC units) - The Fireboy-Xintex Series is a low profile horn/strobe combination that offers dependable, audible and visual alarms with the lowest current available. - The Fireboy-Xintex Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. - The Fireboy-Xintex Series horn offers a continuous or syncable temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for the professional to change in the field by using switches. - The Fireboy-Xintex Series has a minimal operation regardless of input voltage. - The Fireboy-Xintex Series is shipped with the standard 4” metal mounting plate which incorporates the popular Super-SlideTM feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. - The Fireboy-Xintex Series also features the CheckmateTM - Instant Voltage Verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. - The Fireboy-Xintex Series appliances are UL 464 and UL 1971, listed for use with fire protective systems and are warranted for three years from date of purchase. Fireboy-Xintex, Inc. O-379 Lake Michigan Drive Grand Rapids, MI 49534 . 616.735.9380 Fireboy-Xintex, Ltd Unit 10 Holton Road, Holton Industrial Estate Poole, Dorset BH166LT UK . 44 (0) 845 389 9462
Open the catalog to page 1Ordering Codes Part Number 24V Selectable Candela Low Profile Evacuation Horn/Strobe - Wall Mount, Red Faceplate VF4002-10 Product Strobe Current Ratings Candela current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range 16-33VDC for 24VDC units. For strobes the UL max current is usually at the minimum listed voltage 16VDC for 24VDC units. For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Horn Mode Minimum dBA @ Minimum dBA @ Regulated 24VDC 10 ft....
Open the catalog to page 2Mounting Super-Slide Candela Selection Die Cast Metal Mounting Plate: Mounts to single gang, double gang 4" square boxes or VF4005 box. Candela selection slider switch. Depress center and slide switch to desired brightness level. Break off pin and insert into selectorto lock candela setting. Signal must be removed from bracket and pin pushed forward from backside out of hole Checkmate™ - Instant Voltage Verification Switch Locations The access holes are provided in the back of the terminal blockto allowthe voltage to be measured directly without removingthe device. Typically this would be...
Open the catalog to page 3Wiring Diagram Fireboy-Xintex Series with Fireboy-Xintex Synchronization Module WIRING ONLY. AUDIBLE SIGNAL VISIBLE SIGNAL WIRING ONLY. WIRING ONLY. REMOVE JUMPER SYNCHRONIZED STROBE LEAVE JUMPERIN PLACE HORN INPUT ON AVSM TO NOTIFICATION ALARM CIRCUIT TO NOTIFICATION ALARM CIRCUIT LEAVE JUMPER IN PLACE ON SLAVE UNITS UNLESS SEPARATE CONTROL OVER HORN CKT WIRING ONLY Architects and Engineer Specifications The audible and/or visible signal shall be Fireboy-Xintex VF4002-10 series or approved equal and shall be listed by Underwriters Laboratories, Inc. per UL 1971 and/or UL464. The...
Open the catalog to page 4All Fireboy - Xintex catalogs and brochures
-
Deckhead Mounting Box
1 Pages
-
Sounder Beacon Base
1 Pages
-
Relay Output Module
1 Pages
-
Elite RSM Fire Alarm Control
2 Pages
-
Methane Detectors
4 Pages
-
Elite Networking
2 Pages
-
Sounder Control Module
1 Pages
-
Low Power Relay Base
1 Pages
-
Isolating Base
1 Pages
-
4? Mounting Base
1 Pages
-
Mini Monitor Module
1 Pages
-
Isolator
1 Pages
-
Discovery Heat Detector
2 Pages
-
12 Ah Battery
2 Pages
-
Multi Flex Sounder Base
2 Pages
-
Multi-Tone Strobe
3 Pages
-
Fire Suppression & Detection
13 Pages
-
fire alarm
2 Pages
-
propaneSystems
4 Pages
-
MONITOR UP TO 16 ZONES
1 Pages
-
Elite RS-M
2 Pages
-
FIRE DETECTION SYSTEM
1 Pages
Archived catalogs
-
MethaneFumeDetector.pdf
1 Pages
-
Carbon monoxide detector
12 Pages
-
GA Series
2 Pages