Single Action Addressable Pull Station
2Pages

{{requestButtons}}

Catalog excerpts

Single Action Addressable Pull Station - 1

Single Action Addressable Pull Station: VF3033-1M SLC Devices Application Dual Action Addressable Pull Station: VF3034-1M Standard Features - The VF3033-1M and VF3034-1M are versatile, high-quality, metal Fire Alarm Pull Stations designed to meet any installation demand. - Available in both single VF3033-1M and dual action VF3034-1M configurations. VF3033-1M and VF3034-1M pull stations are integrated with the analog single contact module to provide a simple-to-install addressable pull station. The normally open contact of each station, which closes when the pull station is activated, is rated for 1 Amp, 30VDC. The contacts are gold plated to avoid risk of corrosion. - All VF3033-1M and VF3034-1M models have been tested by UL and found in compliance to the latest requirements of the American’s With Disabilities Act (ADA). VF3033-1M and VF3034-1M stations from Fireboy-Xintex are available with key reset. Key reset models are available for interchangeable keys. All models mount on a standard, single gang backbox, Fireboy-Xintex VF3007-10 interior surface metal backbox, or model VF3008-10 weather proof backbox interior surface metal backbox, or model VF3008-10 weatherproof backbox. - Single or Dual Action - Wire head Connections - Gold Plated Alarm Contacts - Surface or Weatherproof Backbox - Optional Auxiliary Alarm Contacts - Optional Station Colors - Combined with the 92132 to provide an addressable interface to the Elite SLC loop Overview - The VF3033-1M and VF3034-1M series pull stations are operated by pulling the handle marked “PULL” on the front of the station as far down as it will go. At that point, the station will lock in place and is easily visible from up to 50 feet. The activation handle is reset by opening the station with the hex wrench or key, placing the handle in the normal upright position and relocking the station. - On the dual action, the push bar rotates inward allowing the “PULL” handle to be grasped and operated by a single hand. - Up to 126 devices can be placed on the Elite SLC loop. The module supervises the wiring to the contact with an End Of Line (EOL) resistor. It can be programmed to monitor normally open (NO) or normally closed (NC) contacts. If a fault condition occurs in the wiring, the module sends a trouble status signal to the fire alarm control panel. When a change of status is sensed by the fast response contact module, it sends an interrupt to the control panel indicating that an alarm has occurred. - After addressing, Manual Pull Stations are fully configurable through Loop Explorer USCG Type Approved 161.002/A53/0 Fireboy-Xintex, Inc. O-379 Lake Michigan Drive Grand Rapids, MI 49534 . 616.735.9380 Fireboy-Xintex, Ltd Unit 10 Holton Road, Holton Industrial Estate Poole, Dorset BH166LT UK . 44 (0) 845 389 9462

Open the catalog to page 1
Single Action Addressable Pull Station - 2

Engineering Specification Technical Specifications The Dealer shall furnish and install where indicated on the plans, Single or Dual Action Addressable Pull Station, Fireboy-Xintex part number VF3033-1M or VF3034-1M, depending on customer or specifier requirements. Rated voltage DCP powered loop: 17-41 VDC State-of-the-art communications protocol, DCP, allows multiple system component types to be used concurrently in a system’s signal conditioning loop. Maximum humidity: 90% RH non-condensing Average consumption: 3.5mA Alarm current: 17-28 VDC Transmission: DCP - Digital Communication...

Open the catalog to page 2

All Fireboy - Xintex catalogs and brochures

  1. Isolator

    1 Pages

  2. fire alarm

    2 Pages

  3. Elite RS-M

    2 Pages

Archived catalogs

  1. GA Series

    2 Pages