GA Series
2Pages

{{requestButtons}}

Catalog excerpts

GA Series - 1

Total Flooding Fire innovative Pre-Engineered System Design For engine rooms from 1,600 cubic ft. to 3,000 cubic ft. ► Each system includes twin extinguisher tanks, flexible braided stainless steel hosing, two overhead temperature sensors, fire resistant manual release cables, and an engine shutdown ► Four temperature sensors monitor engine room temperature 24 hours per day. When engine room temperature reaches 175°F (79°C), the system will discharge. ► Complete system and components custom fitted for each application ► Exclusive, patent pending safety lock poppet valve that eliminates accidental discharge ► Simple and less costly system installation compared to engineered systems - no third party certification required Extinguisher Cylinders: Steel cylinders, DOT and FM approved for the GA Series working pressure and powder coated red for corrosion protection Safety Lock Poppet Valve: Patent pending system that prevents accidental discharge during shipping, warehouse handling, and installation I_ Braided Stainless Steel Typical Engine Room Twin Extinguisher Cylinders Overhead Temperature Sensors Safety Lock Poppet Valve GA Link: Flexible braided 316 stainless steel hosing with double check valve quick-connect couplings for easy attachment/re-attachment to the cylinder valve Overhead Temperature Sensors: Mounted over the engines to monitor ambient engine room temperature; trigger system discharge upon reaching 175°F (79°C) Manual Release Cables: High temperature, fire resistant manual release cables for manual system discharge; install one at each helm station and one at the engine room exit Engine Shutdown Controls: Automatically shuts down engines, generators, blowers and dampers upon system discharge; 3, 5, or 8 circuit shutdowns Engine Shutdown Manual Release Cable Mounting Brackets: Stainless steel, extra heavy duty, vibration tested mounting brackets; three per cylinder HFC-227ea Clean Agent: Approved for normally occupied areas; world wide accepted clean agent with zero ozone depleting potential Double Check Valve Overhead Temperature Dual Release Adapter ngine Room Protection up to 3,000 Cubic Feet

Open the catalog to page 1
GA Series - 2

Selecting the Proper System ► Calculate the gross engine room volume by measuring the length, width, and height ► The gross volume MUST be used unless the boat manufacturer has attached a decal stating the volume of the fixed tanks to be deducted ► Use the "Maximum Volume Protected" column on the chart (below) to determine the model number needed ► Determine the lenghts of stainless steel hose needed (GA Link) ► Select the lengths of Manual Release Cables needed by measuring from the control valve on the cylinder to the mounting point of the tee-handle, including the bends, for both helm...

Open the catalog to page 2

All Fireboy - Xintex catalogs and brochures

  1. Isolator

    1 Pages

  2. fire alarm

    2 Pages

  3. Elite RS-M

    2 Pages

Archived catalogs